background image

 

 

 

 

 

 

 

       

B-800 

USER MANUAL 

 

PLEASE TAKE THE TIME TO READ THESE INSTRUCTIONS BEFORE 

STARTING TO USE THE SCALES

 

Summary of Contents for B-800

Page 1: ...1 B 800 USER MANUAL PLEASE TAKE THE TIME TO READ THESE INSTRUCTIONS BEFORE STARTING TO USE THE SCALES ...

Page 2: ...BATTERY 7 POWER SUPPLY 7 INSTALLING THE BATTERY 8 KEY FUNCTION DESCRIPTION 8 PANELAND LCD DISPLAY 9 LCD DISPLAY 9 SPECIFICATIONS 10 GENERAL WEIGHING OPERATION 11 INSTRUCTION OF HOLD FUNCTION 12 INSTRUCTION OF TARE FUNCTION 13 INSTRUCTION AUTO SHUT OFF FUNCTION 14 INSTRUCTION CALIBRATION FUNCTION 15 INSTRUCTION OF BACKLIGHT FUNCTION 16 INSTRUCTION OF INTERNAL SETTING 17 ERROR MESSAGE 18 ROHS COMPLI...

Page 3: ... instructions When using electrical components under increased safety requirements always comply with the appropriate regulations Improper installation will render the warranty null and void Ensure the voltage marked on the power supply unit matches your mains power supply This device is designed for use indoors Observe the permissible ambient temperatures for use The device meets the requirements...

Page 4: ...e does not require any routine maintenance However we recommend checking the scale s accuracy at regular intervals The regularity of these checks is dependent on the level of use and the state of the scale If any inaccuracies occur please contact your local dealer or service partner DISPOSING OF THE SCALE This product is not to be treated as regular household waste but should be handed in to an el...

Page 5: ...instructions Type B applied part Dispose of old appliances separately from your household waste Instead take them to communal collection points Carefully read this operation manual before setup and commissioning even if you are already familiar with Marsden scales Transport and storage temperature limit indicating the upper and the lower limit Transport and storage temperature on packaging 60 C 20...

Page 6: ...tform 2 Turn the scale base over Insert the base of the digital display into the slot on the bottom of the scale 3 Use the 3 larger screws to secure the digital display to the scale 4 Insert the connector plug of the digital display into the jack in the scale base 5 Use the 4 smaller screws to secure the plastic plate to the base of the digital display the gel padding should face outward ...

Page 7: ...is displayed please change batteries Please refer to INSTALLING THE BATTERY POWER SUPPLY Make sure the battery pack is installed in the battery box of indicator or plug the connector of AC ADAPTOR 9V 0 1A in the scale B 800 uses 4 x AA size alkaline batteries not included for operation If you want scale to be operated by battery please install batteries by referring to instruction below Adaptor pl...

Page 8: ...ower supply KEY FUNCTION DESCRIPTION 1 ON OFF To power ON and OFF the scale 2 UNIT HOLD Press to UNIT select between kg and lb Press 3 Seconds to HOLD Function 3 TARE Press to TARE function Press 3 Seconds to Backlight on or Backlight off Installing 4 AA 1 5V batteries ...

Page 9: ...9 PANEL AND LCD DISPLAY PANEL LCD DISPLAY 1 Stable symbol 2 Minor weight value 3 Low battery ...

Page 10: ...HT Stabilisation Time 1 2 seconds Operating Temp and humidity 0 C 40 C 30 90 RH Transport and storage temperature and humidity 20 C 60 C 25 95 RH Power supply Four 1 5V AA size alkaline batteries ADAPTOR 12v 1A Indicator display 1 5 LCD display with 4 1 2 active digits Dimensions Assembled size 179 245 207 mm Platform size 179 169 58 mm ...

Page 11: ...e factory to weigh in gram g While the scale is on press the UNIT HOLD button to switch to pounds lb 4 Place the item to be weighed onto the platform The display will count up to the weight of the item A Ο icon to the left of the weight digits indicates the weight has stabilized As you add weight the weight displayed increases When all the weight is removed the display will return to zero 5 The sc...

Page 12: ... Release the button 2 Place the item to be weighed on the platform The weight will appear and the triangle icon will stop blinking when the weight is locked in The weight will be held on the LCD when the item is removed The weight will be held for 30 seconds 3 To release the hold function before the scale shuts off press and hold the UNIT HOLD button The LCD will return to zero The scale may be tu...

Page 13: ...ow 8888 then a zero display The weight of the container has been zeroed out 3 Add the ingredient to be weighed The weight of the ingredient alone will display 4 The weight of additional ingredients may be tared out as well For example to measure lb rice and lb beans together place the rice into the bowl Once the correct amount of rice is weighed press the TARE button until the display resets to ze...

Page 14: ...how Set then P 1 00 then A OFF Release the buttons 4 Press TARE The display shows the current auto shut off time example 120S for 120 second auto shut off 5 Press UNIT HOLD to cycle through the options 120S 180S 240S 300S or oFF the scale will remain on until ON OFF is manually pressed 6 Press TARE to select the desired setting The display shows A OFF 7 Press UNIT HOLD until End displays then pres...

Page 15: ...play 2 Press the TARE button The display will show zero 3 Place a calibrated 5 kg weight on the scale platform Choose the the 5 kg weight if it is set to kilograms 4 Press TARE again The LCD will show CAL if the calibration is correct then 10 000 lb or 5000g the calibrated weight used If the calibration is unsuccessful the LCD will show a number between 5000 and 20000 instead of CAL If this occurs...

Page 16: ... for easy viewing While the scale is on press and hold the TARE button for 3 seconds to activate the backlight The backlight will activate for 3 seconds when a button is pushed or when weight is added or removed from the platform Press and hold TARE for 3 seconds to deactivate the backlight ...

Page 17: ...17 INSTRUCTION OF INTERNAL SETTING Press and at same time Select Define ...

Page 18: ...ce with new batteries or plug the AC adaptor for operation Overload The total load exceeds the maximum capacity of the scale Please reduce the loading and try again The scale signal from the load cell error This error is normally caused by a serious fault on the scale us a faulty load cell Please contact the local service representative ...

Page 19: ...rations and applications banned by the directive and for components the product is capable of being worked on at higher temperatures required by lead free soldering The restricted substances and maximum allowed concentrations in the homogenous material are by weight Substance Concentration Lead 0 1 Mercury 0 1 PBB Polybrominated Biphenyls 0 1 PBDE Polybrominated Diphenyl Ethers 0 1 Hexavalant Chro...

Page 20: ...CE SALES SERVICE MARKETING AND ACCOUNTS UNIT 1 GENESIS BUSINESS PARK SHEFFIELD ROAD ROTHERHAM S60 1DX TELEPHONE 0845 130 7330 FAX 0845 1307440 DESPATCH AND PRODUCTION Unit 7 CENTURION BUSINESS PARK COGGIN MILL WAY ROTHERHAM S60 1FB TELPHONE 0845 130 7330 FAX 0845 130 7440 ...

Reviews: