background image

35 Garvey Street 

l

 Everett 

l

 MA 

l

 02149

Tel: (617) 387-4100 

l

 Fax: 1-800-227-2659 (Ex. MA) 

l

 (617) 387-4456 (MA and Overseas)

E-Mail: [email protected] 

l

 Website: www.mfii.com

Form No. S-3117    10/03

An Employee Owned Company

Model:

FT-20CE

OWNERS MANUAL

Self-Contained Electric Steam Jacketed Kettle

COVERING:

INSTALLATION

OPERATION

SERVICE & PARTS

Summary of Contents for FT-20CE

Page 1: ... 800 227 2659 Ex MA l 617 387 4456 MA and Overseas E Mail CUSTSERV mfii com l Website www mfii com Form No S 3117 10 03 An Employee Owned Company Model FT 20CE OWNERS MANUAL Self Contained Electric Steam Jacketed Kettle COVERING INSTALLATION OPERATION SERVICE PARTS ...

Page 2: ...ONS 3 1 Cooking 3 1 3 2 Cleaing 3 2 3 3 Venting 3 2 3 4 Filling Reservoir 3 2 Section 4 ILLUSTRATED PARTS LISTS 4 1 General 4 1 4 2 Ordering Information 4 1 Figure Page Section 2 INSTALLATION 2 1 Front of Kettle 2 1 Section 3 OPERATING INSTRUCTIONS 3 1 Kettle FT 20CE 3 1 3 2 Safety Valve Airvent Rear of Kettle 3 2 Section 4 ILLUSTRATED PARTS LISTS 4 1 Kettle Exterior Components 4 1 4 3 4 6 Wire Di...

Page 3: ... completed through the tilt interlock switch Micro switch 3 Thermostatic control contacts close to energize contactor coils 4 Power is supplied to the elements through closed power contactors 5 As the temperature of water rises in the kettle reservoir increase in steam pressure is indicated on the pressure gauge 6 When the temperature of steam in the reservoir reaches the setting shown on the temp...

Page 4: ...les as per above drawing Drill four 7 6 diameter holes d Apply a continuous bead of Silastic or other equivalent sealant along the complete perimeter edge of the kettle base e Use 5 16 18 x 1 1 2 Hex Cap Screws with suitable flat washers to bolt down f Wipe off excess sealant g A Control Box with power supply equivalent to Electrical Rating of kettle should be located conveniently nearby h A water...

Page 5: ...d into kettle before heating is begun 5 Add food to be cooked into kettle 6 Place thermostat knob at required temperature setting from 1 to 10 coinciding with a temperature range from roughly 90 F to 300 F 32 C to 149 C in the reservoir Approximate cooking temperatures with water at various thermostat settings are as follows THERMOSTAT APPROXIMATE TEMPERATURE WATER SETTING F C 4 90 32 5 125 52 6 1...

Page 6: ...16 wrench open bleed vent one full turn for 10 seconds and close 4 Cool kettle Check for proper vacuum of 25 30 In Hg 84 100k Pa If reading is not low enough repeatentire procedure steps 1 3 3 4 FILLING JACKET RESERVIOR The reservoir water level must be maintained at or above the minimum needed to submerge the heating elements If the low water light turns on during use the water level is not adequ...

Page 7: ...10 97 5009 97 5173 97 5008 97 5011 97 5026 08 6362 97 5144 97 5003 10 7934 20 0043 10 5069 10 5070 97 5025 10 7935 10 3425 97 5145 97 5146 DESCRIPTION Cover Kettle Enclosure FT 20CE Bolt Enclosure Cover Air Vent 7 16 Assy Valve Relief Safely 50PSI Handle Tilt FT 20CE Knob Handle Tilt Switch Power Collar Retaining Switch Interlock Cover Access Element Cover Box Control Liquid Level Control Contacto...

Page 8: ...4 2 Figure 4 2 MODEL FT 20 ELECTRICAL RATING 208 V 12 KW 3Ph 33 4 A 1Ph 57 7 A ...

Page 9: ...4 3 Figure 4 3 MODEL FT 20 ELECTRICAL RATING 220 208 V 12 KW 3Ph 18 3A ...

Page 10: ...4 4 Figure 4 4 MODEL FT 20 ELECTRICAL RATING 240 415 V 12 KW 3Ph 16 7 A ...

Page 11: ...4 5 Figure 4 5 MODEL FT 20 ELECTRICAL RATING 240 V 12 KW 3Ph 28 9 A 1Ph 50 A ...

Page 12: ...4 6 Figure 4 6 MODEL FT 20 ELECTRICAL RATING 480 V 12 KW 3Ph 14 5 A ...