background image

EffEctivE junE 12, 2015

Etp-5G & Etp-10G

Eco-tEch

tm

 plus

Gas convEction stEamEr

parts and sErvicE manual

marKEt forGE industriEs

44 Lakeside Avenue, Burlington, Vermont 05401 USA  Telephone: (802) 658-6600  Fax: (802) 860-3732

www.mfii.com

P/N 14-0284 Rev D

Superseding All Previous Parts Lists.

The Company reserves the right to make substitution in the event that items specified are not available.

ERRORS:  Descriptive and/or typographic errors are subject to correction.

Summary of Contents for ECO-TECH PLUS ETP-10G

Page 1: ...4 Lakeside Avenue Burlington Vermont 05401 USA Telephone 802 658 6600 Fax 802 860 3732 www mfii com P N 14 0284 Rev D Superseding All Previous Parts Lists The Company reserves the right to make substitution in the event that items specified are not available ERRORS Descriptive and or typographic errors are subject to correction ...

Page 2: ...p 10g Table of Contents General Troublshooting Guide 3 Electrical Fault Isolation Guide 5 troubleshooting 6 adjustments 7 Wiring Diagrams 8 Illustrated parts list steamer exploded view 13 Gas Components 17 Cabinet Assembly 19 ...

Page 3: ...nnections Correct as needed STEAM ENTERS COMPART MENT CONTINUOUSLY WITHOUT THE COOKING OR READY LIGHT ON a Standby thermostat not set cor rectly b Faulty thermostatic switch c HOLD set on timer a Adjust the thermostat lower b Replace thermostat c Rotate timer knob to OFF position TIMER DIAL NOT TURNING a Faulty timer motor b Faulty wiring a Replace timer b Inspect condition of wire and light ness ...

Page 4: ...OF SEVERE WATER CONDITIONS WHICH SHOULD BE COR RECTED IMMEDIATELY TO AVOID DAMAGE TO THE COMPONENTS AND PERFORMANCE OF THE STEAMER CALL YOUR SERVICE AGENCY FOR ASSISTANCE WATER ACCUMULATES IN COMPARTMENT a Plugged compartment drain a Remove screen and clean drain line WATER FLOWS INTO DRAIN DURING SHUTDOWN a Cooling valve does not close a Check valve for foreign material or damage WATER NOT BEING ...

Page 5: ...Minute timer b Wiring 3 OPERATES IN 60 MINUTE TIMER POSITION BUT NOT IN HOLD PO SITION a Timer b Wiring c Hold thermostat 4 WITH COOK INDICATOR LIGHT ON AND STEAM ENTERING THE CAVITY TIMER DIAL FAILS TO TURN a Hold position set on timer b Timer motor c Wiring 5 BUZZER FAILS TO SOUND AT END OF 60 MINUTE TIMER MODE a 60 Minute timer contacts b Buzzer c Wiring 6 STEAM FLOWS CONTINUOUSLY FROM BOILER D...

Page 6: ...he fault may be in the door interlock switch Proceed as follows 1 Turn off power to the cooker 2 Disconnect wires to the door switch terminals 3 Connect an ohmmeter between the Common N O Normally Open terminals of the switch 4 Actuate the switch by closing the cooking compart ment door If a zero reading cannot be obtained the switch is defective and must be replaced 5 Remove the ohmmeter and repl...

Page 7: ...o assure your confidence contact your authorized service agency for reliable service dependable advice or other assistance and for genuine factory parts caution Shut off main electrical power to unit Door Gasket Replacement The cooking compartment door gaskets are made of a silicone type rubber material that is very durable but sub ject to wear during normal operation Should the gasket leak replac...

Page 8: ...Wiring Diagrams ...

Page 9: ...Wiring Diagrams ...

Page 10: ...Wiring Diagrams ...

Page 11: ...Wiring Diagrams ...

Page 12: ...king Pilot Red 125V 2 1 15 9 3383 Transformer 120 24V 2 1 16 5162 1 Fill Solenoid Valve 3 2 17 3 S543 Drain Valve 3 2 18 9210 1 Ignition Module 2 1 19 5362 1 Spark Sensor Probe 2 1 20 9092 1 Fuse 1A 250V 220V 2 1 9092 2 Fuse 2A 250V 120V 2 1 21 9068 1 Fuse Holder 2 1 22 9 3175 1 Relay SPDT 2 1 23 5450 1 Gas Valve Natural 2 1 23 5450 2 Gas Valve Liquid Propane 2 1 24 08 6502 Pressure Switch Operati...

Page 13: ...june 12 2015 13 etp 5g etp 10g steamer exploded view ...

Page 14: ... 13 08 7521 Temperature Indicator 1 2 91 6491 Grommet 1 2 14 97 6227 Outer Door Shell 1 2 15 97 6432 Door Handle Assembly 1 2 16 97 6232 Latch Assembly 1 2 17 97 6236 Spacer 2 3 18 97 6261 Bushing 4 8 19 97 6230 Door Panel 1 2 20 97 6228 Door Gasket 1 2 21 97 6229 Gasket Retaining Plate 1 2 22 97 6233 Gasket Panel Screws 8 16 23 97 6481 Hose Clamp 5 8 10 20 24 97 6434 Hose 5 8 I D x 30 Long Upper ...

Page 15: ...3 8 C x 1 8 MPT 1 1 42 97 6442 Bulkhead Union 3 8 C 2 2 43 97 6443 Hose Clamp 1 1 16 2 2 4 44 97 6444 Drain Hose 1 1 4 x 1 3 4 Long 2 2 45 97 6445 Drain Tube Assembly 1 2 46 97 5702 Cord Set 120V 1 1 47 97 6418 Generator Tank Lower 1 48 97 6419 High Limit Thermostat 1 2 49 97 5948 Liquid Level Control 10K OHM 1 2 Liquid Level Control 1M OHM Optional 1 4 50 97 5701 Transformer 120 24V 1 2 51 97 504...

Page 16: ... 6372 Probe High Level 1 2 71 97 6213 Probe Low Level 1 2 72 97 6212 Probe Low Level Cut Off 1 2 73 08 6502 Pressure Switch 1 2 74 97 6559 Generator Tank Top 1 1 75 97 6446 Tubing Pressure Switch 1 4 I D x 8 Long 1 2 76 97 6447 Brass Hose Barb 1 4 x 1 8 MPT 2 4 77 97 6448 Pressure Switch Bracket 1 2 78 08 5015 Vacuum Breaker 1 2 79 97 6449 Tubing Vacuum Break 1 4 I D x 2 Long 1 2 80 97 6450 Brass ...

Page 17: ...june 12 2015 17 etp 5g etp 10g Gas Components ...

Page 18: ... 2 10 97 6532 Lower Gas Flex Tube 5 8 O D x 24 Long 1 1 11 97 6464 Hex Screw 8 32 x 1 4 4 8 12 97 6244 Pilot Burner LP Gas 1 2 97 6465 Pilot Burner Natural Gas 1 2 13 97 6245 Burner Mounting Bracket 1 2 14 97 6466 Machine Screw 10 32 x 3 8 2 4 15 97 6467 Machine Screw 10 32 x 1 4 2 4 16 97 6242 Spark Electrode 2 17 97 6468 Pilot Tube Top 1 97 6469 Pilot Tube Bottom 1 97 6533 Pilot Tube 1 18 97 647...

Page 19: ...19 etp 5g etp 10g Cabinet Assembly 1 2 3 4 5 6 7 8 9 10 14 24 23 22 21 11 12 13A 7 5 6 26 12 25 44 28 29 31 17 6 5 12 6 5 12 13A 42 38 39 31 30 46 40 47 34A 36 37 35 34 33 27 32 13 12 18 19 41 16 15 5 12 45 43 48 20 ...

Page 20: ...ose 5 8 I D x 16 Long 1 97 6480 Hose 5 8 I D x 14 Long 1 13A 97 6480 Hose 5 8 I D x 14 Long 1 1 14 08 6514 Tank Thermostat 130 F 1 1 15 97 6482 Brass Bushing 1 2 MPT to 3 8 FPT 1 1 16 97 6483 Brass Elbow 90 5 8 C x 1 2 FPT 1 1 17 97 6346 Brass Elbow 90 3 8 C x 3 8 MPT 1 1 18 97 6484 Vent 1 1 19 97 6486 Flanged Foot 2 2 97 6406 Swivel Caster 5 c w Brake Optional 2 2 20 97 6486 Adjustable Flanged Fo...

Page 21: ... 3 8 Brass 2 2 36 97 6550 Connector 3 8 C to 3 8 Nylon 1 1 37 NPN Tubing 3 8 O D x 8 Long Copper 1 1 38 08 8020 Filter Large See Item 42 1 1 39 08 8008 Filter Small Scale Inhibitor See Item 42 1 1 40 08 8007 Meter 2 6 41 97 6411 Drain Collector 1 1 42 08 8052 Kit Filter Replacement Cartridges 1 1 43 7844 1 Lower Cabinet Shield 1 7844 2 Lower Cabinet Shield 1 44 08 8059 Pressure Gauge 1 1 45 7845 1...