background image

Use chart at right to 

determine the 

mini-

mum

 gauge cable to 

be used, depending 

on the wattage of 

the power pack. Us-

ing larger cable will 

increase light output. 

For Malibu cable, contact your supplier. 

WARNING—RISK OF FIRE: 

Do not use cable smaller than listed in the table.

Malibu cable is prepared, ready to con-

nect to the power pack. If using other 

cable, split one end of cable for about 

3”, being careful when splitting NOT to 

expose the copper wire. Then strip 5/8” 

of insulation from the end. Also, refer to 

strip length guide on the power pack.

5/8“

3”

5/8“

3”

Lay power pack on a flat, stable surface and insert 

the stripped end of one wire under terminal clamp-

ing plate 

A

. Then tighten the screw. Repeat this 

procedure for clamping plate 

B

. Do not exceed the 

wattage rating of the power pack. NOTE: The 

C

 

terminal is only used to connect an optional photo 

control. 

WARNING—RISK OF FIRE: Make sure there is no wire 

insulation under the clamping plate, and firmly tighten the terminal 

screws.

Terminal Blocks

A B C

Terminal Blocks

A B C

Route the low-voltage cable to fixtures. If there is extra cable, coil it 

after last fixture or cut it off and discard. If you are using cable that 

came with power pack and fixtures, leave about 12” of cable after 

the last fixture. Be sure to leave at least 10 wire feet between the 

power pack and first fixture. Do not yet hide or bury cable. 

WARN-

ING—RISK OF FIRE: Do not coil cable around power pack.

Locate the manual ON/OFF switch on power pack and move it to 

the ON position.

1

  Select Cable 

3

  Prepare Cable 

4

  Connect Cable to Power Pack 

Mount power pack vertically outdoors 

only. 

WARNING—RISK OF FIRE OR 

ELECTRICAL SHOCK: Make sure Power 

Pack is at least 1 foot above ground 

and at least 10 feet from pool or spa. 

Plug into GFCI outdoor electrical outlet 

protected by a weatherproof cover (not 

supplied–Malibu recommends genuine 

Intermatic weatherproof covers). Make 

sure outlet is working.

12”

GFCI

12”

GFCI

7

  Turn Power Pack ON

6

  Run Cable 

Attach fixtures to cable using cable connectors as 

shown. Place one connector on each side of cable, 

then press together to lock. Prongs will pierce cable 

to make contact, and fixture should light up.

8

  Attach Fixtures to Cable 

Set ON and OFF times by setting tripper locations:

Insert a red ON tripper 

(A)

 at the time you want 

the lights to turn on.
Insert a black OFF tripper 

(B)

 at the time you 

want the lights to turn off.
Use a second set of red and black trippers if you 

want another ON/OFF cycle.

a.

b.

c.

A

B

A

B

9

  Set Timer ON / OFF Times 

Set time of day on the timer as follows:

Make sure the Power Pack is plugged in and 

turned ON.
Turn the dial to the present time of day as 

shown by the arrow 

(C)

.

Turn the dial one or more complete revolutions, 

then return to the present time of day.

The lights will now turn ON and OFF at the times you have set.
You can manually operate the lights by turning the Manual ON/OFF 

Switch 

(D)

.

a.

b.

c.

C

D

C

D

10

  Set Time of Day

Once all fixtures are in place and you are satisfied with their loca-

tions, cable may be protected by covering or burying up to 3” deep. 

Remember, if you are using cable that came with the power pack 

and fixtures, leave about 12” of cable after the last fixture and lay 

excess cable between fixtures. 

WARNING—RISK OF FIRE: Do not 

coil excess cable except after the last fixture.

11

  Protect or Hide Cable 

Power Pack Wattage

Minimum Gauge Cable

217-300

12

157-216

14-12

121-156

16-14-12

0-120

18-16-14-12

ML88T Model / Modelo / Modèle 

POWER PACK / TRANSFORMADOR / BLOC D’ALIMENTATION

Lay the fixtures out where you want to locate them. The first 

fixture should be at least 10 wire feet from the power pack. Mount 

them permanently if you wish. 

WARNING—RISK OF ELECTRICAL 

SHOCK: Do not place a fixture within 10 feet of a pool or spa.

2

  Place Fixtures 

Mount power pack vertically at least one foot above ground. Do not lay 

on the ground.
Plug power pack directly into an outdoor GFCI outlet with a weather-

proof cover marked “wet location.” Do not use extension cords.
Mount power pack at least 10 feet from pool or spa.
When connecting wire at terminals, do not allow insulation to get under 

the clamping plate, and firmly tighten the terminal screws.
Do not use cable smaller than listed in the table below.
Do not coil extra cable around the power pack. Either cut off extra 

cable and discard, or leave at the end away from the power pack.
Do not repair or tamper with cord or plug.
Do not submerge power pack.
Do not connect two or more power packs in parallel.
Do not use with a dimmer.
If house circuit breaker trips when power pack is turned on, unplug 

power pack from AC outlet, correct fault, restore power, then reset 

circuit breaker.
Power pack and fixtures must be installed in compliance with national 

and all local electrical codes and ordinances.
If necessary to splice cable, carefully follow instructions that came 

with the connector you have purchased.

WARNING: Risk of Fire or Electrical Shock

Make sure power pack is plugged in. Is outlet working?
Turn timer manual switch to “ON” or rotate dial so “ON” tripper passes 

time line indicator.
Is lamp burned out? Use another lamp to test.

NOTE: This lighting system is designed to last many years under normal 

conditions. However, lamps eventually burn out and operating with one 

lamp out can shorten the life of the others. Conditions beyond control 

(high input voltage, poor voltage regulation, etc.,) will also affect lamp 

life. IT IS IMPORTANT TO REPLACE BURNED OUT LAMPS PROMPTLY.

 Suggestions to Solve Problems Quickly 

5

  Mount Power Pack 

VEUILLEZ LIRE LES DIRECTIVES 
AVANT D’UTILISER CE PRODUIT.

READ INSTRUCTIONS BEFORE 
USING THIS PRODUCT.

LEA LAS INSTRUCCIONES ANTES 
DE USAR ESTE PRODUCTO.

El cable de Malibu está preparado, listo 

para conectarlo al transformador. De lo 

contrario, si usa otro cable, separe un 

extremo del cable aproximadamente 3 

pulgadas (7,6 cm), tenga cuidado cuando 

lo separe de NO exponer el hilo de co-

bre. Después, retire 5/8 pulgadas (16 mm) del aislante del extremo. 

Consulte la guía de longitud de desforre del transformador.

16 mm

7.6 cm

16 mm

7.6 cm

3

  Preparación del cable 

Instale el transformador en una superficie plana y 

estable e inserte el extremo sin material aislante 

debajo de la placa de fijación del terminal 

A

. Lu-

ego, apriete el tornillo. Repita este procedimiento 

para ajustar la placa de fijación 

B

. No exceda la 

capacidad nominal de vatiaje del transformador. 

NOTA: El terminal 

C

 se usa sólo para conectar un control fotoeléc-

trico opcional. 

ADVERTENCIA—RIESGO DE INCENDIO: Asegúrese 

que el aislante no se encuentre debajo de la placa de fijación y los 

tornillos de la terminal estén firmemente ajustados.

Bloques de Terminales

Bloques de Terminales

4

  Conexión del cable al transformador 

Use la tabla que 

aparece a la derecha 

para determinar el 

calibre mínimo del 

cable que se va a 

usar, dependiendo 

del vatiaje del trans-

formador. Al usar un 

cable más grande 

aumentará la emisión luminosa. Para conseguir un cable de Malibu, 

comuníquese con su proveedor. 

ADVERTENCIA—PELIGRO DE 

INCENDIO: No use cables más pequeños de los que se mencionan 

en la tabla.

1

  Selección de un cable

Vatiaje del  

transformador

Calibre mínimo  

del cable

217-300

12

157-216

14-12

121-156

16-14-12

0-120

18-16-14-12

Instale las lámparas en el lugar deseado. La primera lámpara se 

debe instalar a una distancia mínima de 10 pies (3 m) del transfor-

mador. Si lo desea instálelas en forma permanente. 

ADVERTEN-

CIA—PELIGRO DE DESCARGA ELÉCTRICA: No instale una lámpara 

a menos de 10 pies (3 m) de una piscina o spa.

2

  Instalación de las lámparas 

Instale el transformador en forma vertical al menos un pie (30 cm) sobre 

el suelo. No lo instale en el suelo.
Conecte el transformador directamente a un tomacorriente GFCI exte-

rior protegido por una cubierta protectora contra la intemperie marcada 

como apta para “lugares humedos”. No use cables de extensión.
Instale el transformador al menos a 10 pies (3 m) de la piscina o spa.
Al conectar el cable a las terminales asegúrese que el aislante no se 

encuentre debajo de la placa de fijación y los tornillos de la terminal 

estén firmemente ajustados.
No use cables más pequeños de los que se mencionan en la tabla que 

aparece a continuación.
No enrolle el cable sobrante alrededor del transformador. Puede cortar 

el cable sobrante y desecharlo o bien, dejarlo hasta el extremo lejos 

del transformador.
No repare ni modifique de ninguna manera el cable o enchufe.
No sumerja el transformador.
No conecte dos o más transformadores en paralelo.
No lo utilice con un atenuador de luz.
Si el cortacircuito salta cuando se enciende el transformador, des-

enchúfelo del tomacorriente de CA, corrija la falla, vuelva a restablecer 

la red eléctrica y active nuevamente el cortacircuito.
El transformador y las lámparas se deben instalar de acuerdo con todos 

los códigos y normas nacionales y locales.
Si es necesario empalmar cables, siga atentamente las instrucciones 

que se incluyen con el conector que adquirió.

ADVERTENCIA: Peligro de incendio o descarga eléctrica

Instale el transformador en forma 

vertical en exteriores solamente. 

ADVERTENCIA—PELIGRO DE IN-

CENDIO O DESCARGA ELÉCTRICA: 

Asegúrese de instalar el transfor-

mador al menos 1 pie (30 cm) sobre 

el suelo y por lo menos a 10 pies (3 

m) de una piscina o spa. 

Conéctelo 

a un tomacorriente eléctrico GFCI 

exterior protegido por una cubierta 

protectora contra la intemperie (no se incluye, Malibu recomienda 

cubiertas protectoras contra la intemperie originales de Intermatic). 

Asegúrese de que el tomacorriente esté en buen estado.

30 cm

GFCI

30 cm

GFCI

5

  Instalación del transformador 

Extienda el cable de bajo voltaje hasta las lámparas. Si sobra cable, 

enrolle el cable sobrante después de la última lámpara o córtelo y 

deséchelo. Si está usando el cable que viene con el transformador y 

las lámparas, deje aproximadamente 12 pulgadas (30 cm) de cable 

después de la última lámpara. Asegúrese de dejar al menos 10 pies 

de cable entre el transformador y la primera lámpara. No oculte ni 

entierre el cable todavía.  

ADVERTENCIA—PELIGRO DE INCENDIO: No enrolle el cable so-

brante alrededor del transformador.

6

  Cable tendido 

For Missing / Damaged Parts from Newly Purchased Products:

Si el producto que acaba de adquirir está incompleto o tiene piezas dañadas, noti-
fique el problema a través de:  
En cas de pièces manquantes / endommagées dans des produits tout neufs: 

www.intermatic.com/warranty

  

or/o/ou  

1-800-492-2289

For Customer Service or To Purchase Replacement Parts, call:

1-815-675-7000

158ML12901

Reviews: