background image

 

1/ 

8

Model No.

 Description

Continuous Rating (W)

Voltage (V)

Cycle (Hz)

Input

Output

Max. Output (W)

---

---

---

---

110

220
230

240

Nozzle .....................................1

Joint .........................................1

Dust bag (capacity of 2L)  .......1  (for some countries) 

5.7

2.9
2.8

2.7

50/60

50/60
50/60

50/60

600

---

---

120

6.8

50/60

---

600

---

---

600

---

---

600

Current (A)

Dimensions: mm (")

Width (W)
Height (H)

Length (L)

479 (18-7/8) 

185 (7-1/4) 

178 (7) 

No load speed: min.

ˉ

¹=rpm

Max. air volume

*

1

: m³/min.

Max. sealed suction: kPa

Protection against electric shock
Power supply cord: m (ft)

*1 

Without Nozzle, Joint

*2 

With Nozzle, Joint

16,000

Model No.

UB1102

Double insulation

Variable speed control

No

4.1

Australia: 0.5 (1.64), Others: 2.5 (8.2)

2.0 (4.3)

5.7

0 - 16,000

UB1103

Yes

0 - 4.1
0 - 5.7

UB1102, UB1103
Blower

Weight according to

EPTA-Procedure 01/2003

*

2

: kg (lbs)

Dust bag assembly

Nozzle assembly

Long nozzle assembly

Flexible hose set

Anchor nozzle set (for vacuum function only)

Bending long nozzle set

PRODUCT

Models UB1102, UB1103 Blowers are successors of UB1100, UB1101.

Their output air volume is 4.1m³/min. over the predecessors 2.8m³/min. 

The other features are as follows:

 • Ergonomic designed handle with elastomer for more comfortable

    and controlled operation

 • Self-standing design enables stationary use, easy storage and upside-down 

    standing

The specification difference between UB1102 and UB1103 is;

UB1102: Single speed

UB1103: Variable speed control by dial and trigger

C

ONCEPT AND MAIN APPLICATIONS 

S

pecification

S

tandard equipment

O

ptional  accessories

Note:

 The standard equipment for the tool shown above may vary by country.

L

H

W

T

ECHNICAL INFORMATION

Summary of Contents for UB1102

Page 1: ...lower Weight according to EPTA Procedure 01 2003 2 kg lbs Dust bag assembly Nozzle assembly Long nozzle assembly Flexible hose set Anchor nozzle set for vacuum function only Bending long nozzle set PR...

Page 2: ...ng Field Assemble Switch by reversing the disassembly procedure Refer to Fig 1 Note When mounting Handle cover be careful of the following Switch and Lead wire are not pinched with Handle cover Refer...

Page 3: ...mall screwdriver until it stops Refer to the drawing on the top right in Fig 2 Fig 2 ASSEMBLING Fan cover Fan 110 M5 8 Hex nut Flat washer 5 Flat washer 8 1 Remove Nozzle Nozzle 3 Unscrew five 4x18 Ta...

Page 4: ...2 Disassemble Fan section as drawn in Fig 2 3 Disassemble Armature as drawn in Fig 4 Fig 3 Fig 4 Flat washer 8 Armature Fan housing complete 1 Unscrew four 4x35 Tapping screws and disassemble Fan hou...

Page 5: ...rminal Field Field 1 Unscrew four 4x18 Tapping screws and remove Handle cover 3 Disconnect Ring terminals from Brush holders with a Slotted screwdriver Note Tapping the edge of Motor housing with a pl...

Page 6: ...l 1R370 Fig 7 1R063 Field 3 Connect field lead wires to Switch and mount Handle cover to Motor housing with four 4x18 Tapping screws Refer to the drawings on the top left and right in Fig 5 4 Insert A...

Page 7: ...Motor housing complete Wiring of Field lead wires connected to Switch Slit Field lead wires Lead wire holder 1 Mount Filed to Motor housing complete as shown below Lead wire white or blue of Power sup...

Page 8: ...Line filter if used Set Line filter with Field lead wires between Lead wire holders 1 Pass Field lead wires through Line filter and wind them one turn and pass them again as shown below 2 Winded Filed...