Premium & Sérénité

USER MANUAL

iMAGI+

v.201808

Summary of Contents for iMAGI+ Premium

Page 1: ...Premium S r nit USER MANUAL iMAGI v 201808...

Page 2: ......

Page 3: ...led 15 XIII pH sensor iMAGI PREMIUM 16 1 pH sensor 16 2 Winterizing pH ORP sensors if installed 16 3 Procedure to follow 16 XIV Treatments iMAGI Serenity 17 XV The different treatments 18 1 REDOX Sere...

Page 4: ...ver you are in the world So that you can benefit from all the advantages offered by iMAGI we invite you to discover below the full descriptions of each function WARNING Any modification related to the...

Page 5: ...GI control panel is equipped with a 30mA differential switch that will protect the installation It is strongly recommended to check the operation of this differential switch at least once at the begin...

Page 6: ...allows you to cancel changes that have not yet been validated and return to the previous menu Pressing this key allows you to validate changes made in a menu and takes you back to the top level menu I...

Page 7: ...see p12 Accessory 1 see p12 Bathing see p13 Filling up see p13 Roller Shutter see p14 Internet see p14 Accessory2 see p12 System see p26 Installer acces with code see p27 Accessory 3 and Accessory 4 n...

Page 8: ...ration needs differ according to the water temperature automatic modes 1 and 2 have 2 different settings depending on whether the water temperature is above or below 24 C Press the info key to find ou...

Page 9: ...y the user STEP 1 Set the set temperature to switch between the 2 time calendars by pressing the or keys STEP 2 Select the time schedule according to the set temperature by pressing the upper button S...

Page 10: ...the button to increase the bathing temperature Press the button to lower the bathing temperature c ECO MODE If you have chosen eco mode you define a temperature lower than the swimming temperature wh...

Page 11: ...eating operation depending on the choice of heating mode Filtration mode The heating priority is not active and the heating only works during filter hours Adjustable mode This mode makes heating prior...

Page 12: ...s The OFF button turns off your projector s or accessories In manual mode your projector s remains on until the OFF button is pressed 2 MODE AUTOMATIQUE Automatic mode allows you to automatically mana...

Page 13: ...vate the swimming mode If you shorten the Swim mode with the OFF key the filtration and your automatic treatment if installed will stop and resume their normal operating cycle IX FILLING This menu all...

Page 14: ...reens the internet connection does not work XI ROLLER SHUTTER optional This menu allows you to check the status of your Magiguard security flap The opening or closing state of your shutter also allows...

Page 15: ...ature drops below 10 the pump will run for 30 minutes every hour Changing Default Settings You can change the values by pressing the SETTINGS button Alarm ifT C Water 5 0 C Pressing the key increases...

Page 16: ...of an active wintering of your pool you can leave your probes installed on the hydraulic loop located in your technical room protected from frost In the case of passive wintering you must remove your...

Page 17: ...Commissioning of treatments To turn on the treatments pH and Chlorine you must press the adjustment button for each treatment and press OFF to activate the treatment If the key is ON in green the trea...

Page 18: ...treatments is as follows S R NIT REDOX S R NIT SEL S R NIT O2 S R NIT PRO PREMIUM Analysis chamber Redox Probe Treatment box pH sensor 1 REDOX SERENITY PH AND LIQUID CHLORINE TREATMENT Dosing pump pe...

Page 19: ...in ON mode for The whole thing to work but everything is already set at The factory To calibrate The probes go to PROBE CALIBRATION and follow The steps requested Possible settings for a REDOX Serenit...

Page 20: ...fr 2 SEL SERENITY PH TREATMENT AND ELECTROLYSER The possible settings for a SEL Serenity treatment are the same as for the REDOX Serenity treatment Treatment box Redox Probe pH sensor Electrolyser Ana...

Page 21: ...osing pumps The only difference is that there is only the pH probe on the analysis chamber Press left to adjustThe pH treatment Press right to set Active Oxygen treatment to calibrate The probes go to...

Page 22: ...73 69 64 60 57 54 51 49 47 45 43 70 m3 1199 600 400 300 240 200 171 150 133 120 109 100 92 86 80 75 71 67 63 60 57 55 52 50 80 m3 1371 685 457 343 274 228 196 171 152 137 125 114 105 98 91 86 81 76 7...

Page 23: ...User manual 23 v 201808 www magiline fr 4 SERENITY PRO PH AND LIQUID CHLORINE TREATMENT Treatment box pH sensor Analysis chamber Redox Probe Dosing pump peristaltic Dosing pump peristaltic...

Page 24: ...n ON mode for The whole thing to work but everything is already set at The factory To calibrate The probes go to PROBE CALIBRATION and follow The steps requested R glages possibles pour un traitement...

Page 25: ...mum water temperature for automatic treatment not reached NO MAINTENANCETYPE AND FREQUENCY Frequency of intervention Equipment Article Codes D signation 6 months 1 year 2 years 3 years Peristaltic pum...

Page 26: ...030 Pressing this key decreases the date by one day Pressing this key decreases the date by one month Pressing this key decreases the date by one year After making changes in this menu press the execu...

Page 27: ...e parameter value by 1 unit Press the key to decrease the parameter value by 1 unit The value of the settings is between 0 and 120 units XVII INSTALLER This menu is reserved for MAGILINE Pools approve...

Page 28: ...spotlights on or off Allows you to change the lighting mode Allows you to change the color in the selected mode Returns to the previous color in the selected mode Allows you to activate or deactivate...

Page 29: ...ies AAA that you will need to replace To do this you will have to follow the steps of this procedure to the letter a IDENTIFICATION AND INSERTION Notch located at the bottom end of the remote control...

Page 30: ...ING USED BATTERIES Remove used batteries Step1 Then install the new batteries Step2 Reposition the front panel paying particular attention to the joint then replace the fixing screws Reposition the co...

Page 31: ...the box Unscrew the 2 screws fixing the cover of the radio box with a Phillips screwdriver Place a small flat screwdriver in the notch and gently lift the lid Removing and replacing batteries Step 1 R...

Page 32: ...t pool water level Pump pressure sensor defective Pump defective Checking the suction strainer for dirt Checking the water level Manual reset LACK OF WATER ANALYTICAL CHAMBER See page 17 Discontinuati...

Page 33: ...User manual 33 v 201808 www magiline fr NOTES...

Page 34: ...lutionary Their visual representation in this catalogue is indicative and without contractual scope Our dealers and partners are legally independent companies that carryon their behalf and for their a...