background image

1

LUNA 1000-1150-1300-1600 DH GOLD GAS

                    INSTRUCTION FOR INSTALLATION AND USE

Passion for fire

LUNA 1000-1300-1600 CL / CR GOLD GAS (Corner Left /Corner Right)

LUNA 1000-1300-1600 DC GOLD GAS ( Double Corner )

English 04-2012

Summary of Contents for LUNA 1000 CL Gold Gas

Page 1: ... 1000 1150 1300 1600 DH GOLD GAS INSTRUCTION FOR INSTALLATION AND USE Passion for fire LUNA 1000 1300 1600 CL CR GOLD GAS Corner Left Corner Right LUNA 1000 1300 1600 DC GOLD GAS Double Corner English 04 2012 ...

Page 2: ...AT I O N I N S T R U C T I O N S F O R T H E M D E S I G N G A S F I R E P L A C E S T H E S U P P L I E R TA K E S N O R E S P O N S B I L I T Y F O R A N Y P O S S I B L E D A M A G E P O O R W O R K I N G A P P L I A N C E S A N D A C C I D E N T A S A R E S U LT O F I N C O R R E C T I N S TA L L AT I O N ...

Page 3: ... 5 INSULATION AND FINISHING 13 6 CONVECTION CURRENT 14 15 16 7 MOUNTING A 3 SIDED FRAME 17 8 POSITIONING THE LOGS DIAMOND SAPPHIRE AND WHITE PEBBLES 18 1000 DH CL CR DC 19 20 1150 DH 21 22 1300 DH CL CR DC 23 24 1600 DH CL CR DC 25 26 9 FIRST TIME USE 27 10 SAFETY ADVICE AND MAINTENANCE 27 11 STARTPILOT 28 12 USIGN THE MANUAL CONTROL 28 13 SPECIFICATION SHEET 29 30 31 32 DRAWINGS 33 42 FRAMES 43 4...

Page 4: ... CR DC GOLD GAS 4 OPEN CLOSING KEY IF SOME DUST OR WASTE IS SEEN ON THE WINDOW INSIDE AND OUTSIDE CLEAN THIS BEFORE THE FIRST USE OF THE FIREPLACE CLEANING THE WIN DOW IS THE ONLY MAINTENANCE ACTION THAT CAN BE DONE BY THE CONSUMER OPEN AND CLOSE THE DOOR ...

Page 5: ...r order specifications this appliance is designed for natural or propane gas Read the instructions before installing and using this appliance Before installing the furnace please check the local regulations about this type of furnace identification of the type of gas etc and check that the furnace is adapted to your means of installation CAUTION The furnace must be connected to the type of gas men...

Page 6: ... A min 3 5 cm B 14 5 cm C min 18 cm The stove may not be placed direct ont the floor to allow natural convection The appertures for the air supply IN is situated underneath the appliances Regulating the height of the appliance This can be made in two ways A regulation by 8 times 5 cm pic 1 and a fine regulation by screw pic 2 The minimal height as from ground to the 4th side frame is 3 5 cm A min ...

Page 7: ... 1 3 ELECTRICAL CONNECTION These appliances are equiped with a radiographic remote control making an earthened 220V socket necessary You should bear in mind that the appliance must be connectes from all electrical supply for thurpose of service ITS OBLIGATORY TO CONNECT AN EARTH CURRENT 3 1 2 GAS CONNECTION The appliances are standard delivered with a 1 2 gas solded connection fig 1 It is always l...

Page 8: ...C 3 m 17m Ø 60 as from 2 m Ø 75 1150 DH 3 m 17m Ø 60 1300 DH CL CR DC 3 m 17m Ø 60 1600 DH DC 3 m 19m Ø 75 Ø 200 130 Appliance C min C max Restriction HR as from 3m 1000 DH CL CR DC 2 m 9m Ø 60 as from 2 m Ø 75 1150 DH 2 m 9m Ø 60 as from 2 m Ø 75 1300 DH CL CR DC 2 m 9m Ø 60 as from 2 m Ø 75 1600 DH CL CR DC 2 m 9m Ø 75 as from 2 m Ø 75 DH Double Face CL Corner Left CR Corner Right DC Double Corn...

Page 9: ...ppliance C min C max Restriction HR as from 4m 1000 DH CL CR DC 3 m 17m Ø 60 1150 DH 3 m 17m Ø 60 1300 DH CL CR DC 3 m 17m Ø 60 1600 DH CL CR DC 3 m 19m Ø 75 200 min Ø 130 Appliance C min C max Restriction HR as from 3m 1000 DH CL CR DC 2 m 9m Ø 60 1150 DH 2 m 9m Ø 60 1300 DH CL CR DC 2 m 9m Ø 60 1600 DH CL CR DC 2 m 11m Ø 75 DH Double Face CL Corner Left CR Corner Right DC Double Corner DH Double...

Page 10: ...l exit A Ø 75 1300 DH CL CR DC 1 25 m wall exit A Ø 75 A Ø 200 130 in combination with B Ø 150 100 WITH REDUCTION USVK13 AFTER 90 CURVE ON HORIZONTAL PART FIG 4 Appliance A min Ø 200 130 B min Ø 150 100 B max Ø 150 100 Restriction HR 1000 DH CL CR DC 1 25m wall exit A USVK13 5m Horiz 2m Ø 75 1150 DH 1 25m wall exit A USVK13 4m Horiz 2m Ø 75 1300 DH CL CR DC 1 25m wall exit A USVK13 2 5m Horiz 1m Ø...

Page 11: ... TO HAVE A LITTLE INCLINATION OF 2 OR 3 DEGREES ASCENDING TO AVOID RAIN AND CONDENSATION IN TUBE INSTALL WALL OUTLET LIKE PIC 6 A B Ø 200 130 Appliance A min B min Restriction HR B max 1000 DH CL CR DC 1 m wall exit Ø 70 A 7m 1150 H 1 m wall exit Ø 75 A 6m 1300 DH CL CR DC 1 m wall exit Ø 75 A 5m 1600 DH CL CR DC 1 m wall exit Ø 90 A 3m DH Double Face CL Corner Left CR Corner Right DC Double Corne...

Page 12: ...ly Pic 5 Fig 5 ROOF EXIT with 90 bends Ø 150 100 WITH REDUCTION USVK13 oN APPLIANCE Aplliance A min B max C min A B C max 1000 DH CL CR DC 1 25 m A C B A 1m 17m 1150 DH 1 25 m A C B A 1 16m 1300 DH CL CR DC 1 25 m A C B A 0 5 15m 1600 DH CL CR DC 1 25 m A C 1m B A 14m Ø 200 130 without reduction Appliance A min B max C min A B C max 1000 DH CL CR DC 1 m A C 8m B A 9m 19m 1150 DH 1 m A C 7m B A 8m ...

Page 13: ...ou have checked everything you can perform the final insula ting and finishing operations The built in part of the furnace tends to be very warm Please check that the furnace is not too nar rowly fitted and that there is adequate space for the elimination of hot air For insulation of the furnace we advise you to use M Design insulating plates You are advised against using any other insulation prod...

Page 14: ... grids give off more heat than others and seeing that a hot air pipe functions in a manner similar to a chimney the one that is hot first has the most draught and therefore becomes hot even more quickly Note a circulation of hot air requires that no under pressure be created in the room A grid that is near the floor pic 2 sees to it that cold air can be drawn in M design has developed its ideal ho...

Page 15: ... GAS 15 Design Grid outlet with 2 connections OUTLET CONVECTION INLET CONVECTION OUTLET CONVECTION Inlet Grid convection air Inlet Grid convection air Design Grid outlet with 2 connections 2 dm 4 dm Design Grid outlet with 4 connections OR OR INLET CONVECTION Pic 3 ...

Page 16: ...E STOVE MAY NOT BE PLACED DIRECT ON THE STOVE MAY NOT BE PLACED DIRECT ON THE FLOOR WTHOUT THE FEETS THIS TO ALLOW NATURAL CONVECTION THE APPERTURES FOR THE AIR SUPPLY ARE SITUATED UNDERNEATH THE APLLIANCE EVERY OPENING YOU MAKE MUST BE CONNECTED WITH A FLEXIBLE TUBE dia 150MM see pic below THIS WILL AVOID THE HEATING OF THE ELECTRONIC PART OF THEAPPLIANCE IN OTHER CASE YOU WILL HAVE ERRORCODE F02...

Page 17: ...cm an upper and 2 sideframes see pic 2 Before mounting the 3 sided frame remove 4 sided frame lower piece by lift it carefully up Pull out the upper frame and in second way the left and right sideframes Take the left and right side of the 3 sided frame 3 5 7 or 10 cm and slide them in the notches see pic 4 When those are placed in a good way you can adjust the position to the left en to the right ...

Page 18: ...cooled down Move the window to the front by pulling it The window tips open at 45 Arrange the materials supplied In accordance with your order you will have either a set of logs diamond sapphire or white pebbles There is an adequate supply of materials Our appliance is approved with these materials so please do not use other products Other decorative products are prohibited in our appliances Pleas...

Page 19: ...LUNA 1000DH CL CR DC 1150DH 1300DH CL CR DC 1600DH CL CR DC GOLD GAS 19 1 2 3 4 5 6 7 8 9 5 6 7 8 9 1 2 4 3 LUNA 1000 DH CL CL DC GAS ...

Page 20: ...LUNA 1000DH CL CR DC 1150DH 1300DH CL CR DC 1600DH CL CR DC GOLD GAS 20 LUNA 1000 DH CL CR DC GAS ...

Page 21: ...LUNA 1000DH CL CR DC 1150DH 1300DH CL CR DC 1600DH CL CR DC GOLD GAS 21 1 2 4 3 5 6 7 8 9 5 6 7 8 9 1 2 4 3 LUNA 1150 DH GAS ...

Page 22: ...LUNA 1000DH CL CR DC 1150DH 1300DH CL CR DC 1600DH CL CR DC GOLD GAS 22 LUNA 1150 DH GAS 6 7 ...

Page 23: ...LUNA 1000DH CL CR DC 1150DH 1300DH CL CR DC 1600DH CL CR DC GOLD GAS 23 1 2 3 4 5 6 7 8 9 5 6 7 9 1 2 4 3 8 10 11 12 10 11 12 LUNA 1300 DH CL CR DC GAS ...

Page 24: ...LUNA 1000DH CL CR DC 1150DH 1300DH CL CR DC 1600DH CL CR DC GOLD GAS 24 LUNA 1300 DH CL CR DC GAS ...

Page 25: ...LUNA 1000DH CL CR DC 1150DH 1300DH CL CR DC 1600DH CL CR DC GOLD GAS 25 1 2 3 4 5 6 7 8 9 5 6 7 9 1 2 4 3 8 10 11 12 10 13 13 11 12 LUNA 1600 DH CL CR DC GAS ...

Page 26: ...LUNA 1000DH CL CR DC 1150DH 1300DH CL CR DC 1600DH CL CR DC GOLD GAS 26 LUNA 1600 DH CL CR DC GAS ...

Page 27: ...ken or cracked the appliance must not be used until the window has been replaced Contact your M Design reseller 10 SAFETY ADVICE AND MAINTENANCE Have your furnace inspected once a year by a qualified technician Please observe the following points Closed appliances produce intense heat which means that all the surfaces of the exter nal walls metal door frames and windows become very hot once a cert...

Page 28: ...ption 12 USING THE MANUAL CONTROL BLACK BOX On the user interface a potentiometer is connected This one will be used only when the remote control is broken DON T USE THE POTENTIOMETER SIMULTANIOUSLY WITH THE REMOTE CONTROL TO SET THE REQUIRED LOAD When no ignition with remote control set potentiometer knob off turn left Push once on the black push button You will hear the starpilot ignition Once y...

Page 29: ...t pressure mbar 25 20 30 37 50 28 30 Burner pressure mbar 24 2 19 3 29 4 36 2 36 2 28 4 Consumption m 3 h 0 870 0 789 0 264 0 299 0 299 0 226 Injector burner 6 x 0 95 6 x 0 95 6 x 0 6 6 x 0 6 6 x 0 6 6 x 0 6 Injector startpilot 38 33A 38 33A 0 20P3 0 20P3 0 20P3 0 20P3 Rendement 86 4 86 8 73 73 73 73 Nominal Charge KW 7 7 5 6 5 7 3 7 3 7 3 Charge KW 6 1 6 4 4 7 5 3 5 3 5 3 NOX emmission classe 5 5...

Page 30: ...r 25 20 30 37 50 28 30 Burner pressure mbar 24 2 19 3 29 4 36 2 36 2 28 4 Consumption m 3 h 0 870 0 789 0 264 0 299 0 299 0 226 Injector burner 6 x 1 6 x 1 6 x 0 6 6 x 0 6 6 x 0 6 6 x 0 6 Injector startpilot 38 33A 38 33A 0 20P3 0 20P3 0 20P3 0 20P3 Rendement 83 86 2 73 73 73 73 Nominal Charge KW 7 7 5 6 5 7 3 7 3 7 3 Charge KW 6 1 6 4 4 7 5 3 5 3 5 3 NOX emmission classe 5 5 5 5 5 5 Cat Rendement...

Page 31: ...30 37 50 28 30 Burner pressure mbar 24 19 2 29 2 36 1 36 1 28 2 Consumption m 3 h 1 132 1 026 0 344 0 389 0 389 0 295 Injector burner 6 x 1 10 6 x 1 10 6 x 0 65 6 x 0 65 6 x 0 65 6 x 0 65 Injector startpilot 38 33A 38 33A 0 20P3 0 20P3 0 20P3 0 20P3 Rendement 85 87 70 70 70 70 Nominal Charge KW 9 2 9 7 8 4 9 5 9 5 9 5 Charge KW 8 0 8 4 5 9 6 7 6 7 6 7 NOX emmission classe 5 5 5 5 5 5 Cat Rendement...

Page 32: ...0 30 37 50 28 30 Burner pressure mbar 23 18 8 29 36 36 28 1 Consumption m 3 h 1 393 1 262 0 423 0 478 0 478 0 363 Injector burner 6 x 1 25 6 x 1 25 6 x 0 75 6 x 0 75 6 x 0 75 6 x 0 75 Injector startpilot 38 33A 38 33A 0 20P3 0 20P3 0 20P3 0 20P3 Rendement 85 85 2 68 68 68 68 Nominal Charge KW 11 2 11 9 10 3 11 7 11 7 11 7 Charge KW 9 5 10 1 7 8 8 8 NOX emmission classe 5 5 5 5 5 5 Cat Rendement CE...

Page 33: ...LUNA 1000DH CL CR DC 1150DH 1300DH CL CR DC 1600DH CL CR DC GOLD GAS 33 LUNA 1000 DH GOLD gas gaz Connection Gas ...

Page 34: ...UNA 1000DH CL CR DC 1150DH 1300DH CL CR DC 1600DH CL CR DC GOLD GAS 34 LUNA 1000 CL CR GOLD gas Connection gas on the left for the CR Connection gas on the right for the CL CL Corner Left CR Corner Right ...

Page 35: ...LUNA 1000DH CL CR DC 1150DH 1300DH CL CR DC 1600DH CL CR DC GOLD GAS 35 LUNA 1000 DC GOLD gas Connection Gas ...

Page 36: ...LUNA 1000DH CL CR DC 1150DH 1300DH CL CR DC 1600DH CL CR DC GOLD GAS 36 LUNA 1150 H GOLD gas Connection Gas ...

Page 37: ...LUNA 1000DH CL CR DC 1150DH 1300DH CL CR DC 1600DH CL CR DC GOLD GAS 37 LUNA 1300 DH GOLD gas Connection Gas ...

Page 38: ...A 1000DH CL CR DC 1150DH 1300DH CL CR DC 1600DH CL CR DC GOLD GAS 38 LUNA 1300 CL CR GOLD gas CL Corner Left CR Corner Right CR Connection gas on the left for the CR Connection gas on the right for the CL ...

Page 39: ...LUNA 1000DH CL CR DC 1150DH 1300DH CL CR DC 1600DH CL CR DC GOLD GAS 39 LUNA 1300 DC GOLD gas Connection gas ...

Page 40: ...LUNA 1000DH CL CR DC 1150DH 1300DH CL CR DC 1600DH CL CR DC GOLD GAS 40 LUNA 1600 DH GOLD gas Connection gas ...

Page 41: ...A 1000DH CL CR DC 1150DH 1300DH CL CR DC 1600DH CL CR DC GOLD GAS 41 LUNA 1600 CL CR GOLD gas CL Corner Left CR Corner Right Connection gas on the left for the CR Connection gas on the right for the CL CR ...

Page 42: ...LUNA 1000DH CL CR DC 1150DH 1300DH CL CR DC 1600DH CL CR DC GOLD GAS 42 LUNA 1600 DC GOLD gas Gas Connection ...

Page 43: ...LUNA 1000DH CL CR DC 1150DH 1300DH CL CR DC 1600DH CL CR DC GOLD GAS 43 ...

Page 44: ...eiste 3 5 cm und leiste oben und seite 1000 DC 1300 DC 1600 DC A mm 1008 1308 1608 B mm 367 367 367 C mm 371 371 371 D mm 55 55 55 E mm 35 35 35 1000 DC 1300 DC 1600 DC A mm 1078 1378 1678 B mm 402 402 402 C mm 406 406 406 D mm 90 90 90 E mm 70 70 70 1000 DC 1300 DC 1600 DC A mm 1148 1448 1748 B mm 437 437 437 C mm 441 441 441 D mm 125 125 125 E mm 105 105 105 4 zijdige kader 7cm Cadre 4 coté 7cm ...

Page 45: ...rty including the buyer Heat cracks which normally occur in the mantel In cases where changes have been made to the furnace without our consent In cases where the buyer cannot show his her warranty card with the purchase invoice Li kewise where the guarantee and or the invoice show s signs of tampering or forgery crossed out date illegible modifications In the case you would like to make use of th...

Page 46: ...LUNA 1000DH CL CR DC 1150DH 1300DH CL CR DC 1600DH CL CR DC GOLD GAS 46 15 CE CERTIFICATION ...

Page 47: ...LUNA 1000DH CL CR DC 1150DH 1300DH CL CR DC 1600DH CL CR DC GOLD GAS 47 ...

Page 48: ...LUNA 1000DH CL CR DC 1150DH 1300DH CL CR DC 1600DH CL CR DC GOLD GAS 48 16 SPARE PARTS DOUBLE SIDED ...

Page 49: ...LUNA 1000DH CL CR DC 1150DH 1300DH CL CR DC 1600DH CL CR DC GOLD GAS 49 SPARE PARTS CORNER GAS ...

Page 50: ...LUNA 1000DH CL CR DC 1150DH 1300DH CL CR DC 1600DH CL CR DC GOLD GAS 50 SPARE PARTS DOUBLE CORNER ...

Reviews: