background image

 

 

 

 

 

 

 

 

 

BigEye RGB LED spot 

IP67 version 

Summary of Contents for BigEye IP67

Page 1: ...BigEye RGB LED spot IP67 version ...

Page 2: ...TY INFORMATION 6 4 1 SYMBOLS 6 4 2 PROTECTION FROM ELECTRIC SHOCK 7 4 3 PROTECTIONS FROM FIRE AND BURNS 7 4 4 PROTECTION FROM INJURY 8 4 5 DISPOSING OF THIS PRODUCT 8 5 PHYSICAL INSTALLATION 9 5 1 UNPACKING 9 5 2 LOCATION AND ORIENTATION 9 5 3 MOUNTING 9 6 EXTERNAL CONNECTIONS 10 7 EMC AND SAFETY REQUIREMENTS 11 8 SERVICE AND MAINTENANCE 12 8 1 SAFETY PRECAUTIONS 12 8 2 CLEANING 12 9 WARRANTY 13 9...

Page 3: ...BigEye RGB LED spot IP67 p 3 16 LUX LUMEN Kernenergiestraat 53A 2610 WILRIJK BELGIUM T 32 3 293 35 50 F 32 3 293 35 44 www lux lumen com 1 Picture ...

Page 4: ...BigEye RGB LED spot IP67 p 4 16 LUX LUMEN Kernenergiestraat 53A 2610 WILRIJK BELGIUM T 32 3 293 35 50 F 32 3 293 35 44 www lux lumen com 2 Dimensions 230 223 73 6 247 19 70 5 183 40 ...

Page 5: ...ditional 700mA led driver and power supply is necessary to use the BigEye RGB LED spot 3 2 Mechanical specs Total weight 590gr 20 8oz Ingress Protection rating IP 67 Aluminium housing 15 µm anodized Aluminium mounting ring 15 µm anodized 24 pcs rebel 3W LED s 8x red 8x green 8x blue on PCB 4mm tempered clear glass All fasteners in stainless steel Robust outdoor cable 3 3 Electrical specs 3 groups ...

Page 6: ... that you read this manual and ensure yourself that you completely understand its content Observe the safety precautions in this manual Install and operate the led unit only as described in this manual and in conformity with local regulations If you have any questions how to operate this product safely please contact your point of sale 4 1 Symbols Following symbols are used to identify important s...

Page 7: ... to local regulations Please ensure yourself that the AC to DC power supply is able to deliver the rated current requirements of the installation If any cable seal or housing is damaged cracked or reformed disconnect the power of the installation immediately For any additional servicing not described in this manual please contact your point of sale 4 3 Protections from fire and burns Do not operat...

Page 8: ...d all its accessories are securely fastened Verify that the led unit is firmly fixed to its supporting underground 4 5 Disposing of this product This led lighting device is manufactured in compliance with directive of the European community waste electrical and electronically equipment Please help to preserve our environment and ensure that this product will be recycled properly at the end of its ...

Page 9: ... yourself that there is sufficient and unrestricted air flow around the RGB LED spot 5 1 Unpacking The following items are included in your package BigEye RGB LED spot complete with focussing bracket Protective antistatic packaging with short form manual 5 2 Location and orientation This BigEye RGB LED spot can be used in all directions 5 3 Mounting Surface mounting The BigEye RGB LED spot can be ...

Page 10: ... with 2 Red Inner conductor marked with 3 Green Inner conductor marked with 4 Blue Improper connection might damage the BigEye RGB LED spot and power supply permanently In case of inversed polarity the warranty is void Connectors Make sure to use IP66 connectors if the use of connectors is necessary in an outdoor environment to obtain IP66 for a complete system The BigEye RGB LED spot can be deliv...

Page 11: ...A1 2007 Radiated immunity test EN 61000 4 4 2004 Fast transients and burst immunity EN 61000 4 5 2005 Surge immunity test EN 61000 4 6 2008 Conducted immunity test EN 61000 4 8 1993 Magnetic field immunity test EN 61000 4 11 2004 Voltage variations immunity test EN 61000 6 1 2005 Generic standards for immunity Emission according to EN 61000 3 2 2005 A1 2008 A2 2009 Harmonics emission test 16A EN 6...

Page 12: ...out the power on the entire system and allow all electronic devices to discharge and cool down before executing any service or maintenance 8 2 Cleaning The RGB LED spot itself Extensive dirt and particle build up degrades performance may cause overheating can result in damaged led unit and power supply s Damage by inadequate cleaning or maintenance is not covered by the product warranty Never use ...

Page 13: ... department will be borne by the customer Limitations Lux Lumen will not warrant the following Periodic check ups maintenance and repair or replacement of parts due to normal wear and tear Consumables Any software Defects caused by modifications carried out without Lux Lumen s approval Damage resulting from the fact that a product is not conforming to country specific standards or specifications i...

Page 14: ...ed with this product Defects caused by improper condition of the power supply network Inadequate packaging of the product when returning it under the RMA procedure Accidents or disasters or any cause beyond the control of Lux Lumen including but not limited to lightning water fire public disturbances improper ventilation and acts of god Others It is the responsibility of the customer to backup and...

Page 15: ...aterial The procedure to obtain a RMA Step 1 Customer contacts Lux Lumen about warranty defects if material has to be returned Step 2 Lux Lumen sends the customer a filled out RMA document using a unique RMA number Step 3 Customer sends material include a copy of the RMA document with the material Step 4 Lux Lumen evaluates the problem and informs the client if repair is done under warranty or mak...

Page 16: ...rgiestraat 53A 2610 WILRIJK BELGIUM T 32 3 293 35 50 F 32 3 293 35 44 www lux lumen com 10 Used list of abbreviations AC Alternating current DC Direct current F Temperature in degrees Fahrenheit C Temperature in degrees Celsius LED Light Emitting Diode ...

Reviews: