background image

KW16

by   

LockTech

www.locktech.biz

[email protected]

Thank you for purchasing the Accu-Reader 

by LockTech wafer reading system.  This system will 
allow you to read the KW16 keyways completely and 
accurately without the removal of any locks. 
Following a few simple steps it takes only minutes to 
read the depths for each cut in each position for a 
complete key.

The Accu-Reader works on the process of 

elimination to decipher the correct depths of the lock. 
By checking the deepest cut first you eliminate what 
the cuts are not.  Therefore it is essential to always 
read depth slide #4 first.

Due to the construction of the KW16 

ignitions, the process for originating a key differs 
slightly from a traditional Accu-Reader.  The primary 
way for originating a key will be from using the Seat 
Lock which has all 6 spaces.  If you find that the 
ignition has been changed out, please refer to KW16 
Ignition Section for instructions on making an ignition 
key.

The Accu-Reader key is designed to be used 

for wafer positions 4-6 on one side of the key and 
wafer positions 1-3 on the opposite side of the key. 
All the positions can be read from one side of the 
key, however it is recommended to flip the key over 
and use the other side.  This allows for reading the 
1-3 wafer positions with a fully or almost fully inserted 
key, increasing the accuracy.

Please take the time to familiarize yourself 

with the tools and verify all pieces are accounted for 
from the list of contents below:

Package Contents:
1-Accu-Reader key
1-insertion/release slide
1-depth slide #4
1-depth slide #3
1-depth slide #2
1-Tube storage container
1-Tube Cap

USING THE ACCU-READER (SEAT LOCK)

1) Always thoroughly clean the lock with a electronics 
safe cleaner to free any potentially stuck wafers.

2) Use the alignment holes through the Accu-Reader 
key to assist in judging the distance from one wafer 
position to the next.

3) Place the insertion/release slide in the slot on the 
accu-reader key on the #4-6 side.  Fully insert the 
accu-reader key into the 

SEAT LOCK

 keyway and 

remove the slide.  The Accu Reader key is now ready 
to read the #6 wafer.  

(Note:  If the Accu-Reader 

trapped a wafer shortly after inserting it into the 
keyway, use the release slide on the opposite 
side of the key to release the Accu-Reader.  This 
happens when wafers fall into the trap slot for the 
1-3 side, since these locks have wafers only on 
one side.  Flip the Accu-Reader over and restart 
step 2).

4) Always

 start reading with the #4 depth slide 

tool, then proceed to #3 & #2 in order, IF 
NECESSARY. 

 Fully insert the depth slide into the 

Accu-Reader key.  The alignment mark on the depth 
slide will line up with the (

Y

Yes

 mark or it will line up 

with the (

N

)

 No 

mark. 

 

a) If the #4 depth slide lines up with the 

then the depth for the #6 wafer is a 4.  If the depth 
slide lines up with a 

N

, then you must 

proceed to the #3 depth slide. 
 

b) If the #3 depth slide lines up with the 

then the depth for the #6 wafer is a 3.  If the depth 
slide lines up with a 

N

, then you must 

proceed to the #2 depth slide.

c) If the #2 depth slide lines up with the 

then the depth for the #6 wafer is a 2.  If the depth 
slide lines up with a 

N

, then the depth for 

wafer #6 is a 1.

d) Repeat steps 

a

 through 

c

 for each wafer 

position until you have recorded the depth for wafer 
position 6, 5, & 4.

e) Using the insertion/release slide remove 

the Accu-Reader key from the keyway and flip it over. 
Insert the insertion/removal slide on the #1-3 side of 
the Accu-Reader and fully insert the Accu-Reader 
key back into the keyway.  You are now ready to read 
wafer position #3.

f) Repeat steps a through c for each wafer 

position until you have recorded the depth for wafer 
position 3, 2, & 1.

g) You now have recorded all the positions to 

make a complete key.

NOTE: 

 The KW16 Accu-Reader will also read the 

gas tank lock following the instructions above, 

Reviews: