background image

 

NTI AG / LinMot 

Dok-Nr. 0185-0118-E_1V0_IG_Power_Supplies_S02_72_1000 

 

Installation Guide Power Supply

 

ENG

 

Type S02-72/1000

 

Power range 1000 W 

 

 

 

 

Summary of Contents for S02-72/1000

Page 1: ...NTI AG LinMot Dok Nr 0185 0118 E_1V0_IG_Power_Supplies_S02_72_1000 Installation Guide Power Supply ENG Type S02 72 1000 Power range 1000 W ...

Page 2: ...fety 4 2 2 Application as directed 4 2 3 Transport Storage 4 2 4 Installation 4 2 5 Electrical Connection 5 2 6 Operation 5 2 7 Protection of Persons 5 3 Mains Connection and Grounding 6 4 Description of the Connectors Interfaces 7 4 1 PE 7 4 2 X30 7 4 3 X56 7 5 LED Blink Codes 7 6 Physical Dimension 8 7 Output Voltage Regulation 9 8 Power Boost 9 9 Ordering Information 10 10 International Certifi...

Page 3: ...r damages and expenses caused by incorrect use of the products This also applies to false applications which are caused by NTI AG s own data and notes for example in the course of sales support or application activities It is the sole responsibility of the user to check the information and information provided by NTI AG regarding their safety relevant correctness In addition the entire responsibil...

Page 4: ...f the procedures and circuit proposals described LinMot servo drives power supplies and the accessory components can include live and moving parts depending on their type of protection during operation Surfaces can be hot o Non authorized removal of the required cover inappropriate use incorrect installation or operation create the risk of severe injury to persons or damage to material assets o Fo...

Page 5: ...ences in non industrial environments which can require measures for interference suppression 2 6 Operation If necessary systems containing switching power supplies must be equipped with additional monitoring and protective devices in accordance with the applicable safety regulations e g law on technical equipment regulations for the prevention of accidents After the power supply has been disconnec...

Page 6: ...nectors must not be connected or disconnected while DC voltage is present Capacitors in the power supply may not fully discharge for several minutes after input voltage has been disconnected Failure to observe these precautions may result in severe damage to electronic components in LinMot motors and or drives Integral solid state short circuit protection does not provide branch circuit protection...

Page 7: ...tor cross section 2 5 4 mm2 AWG 24 12 Stripping length 10 mm external circuit breaker 16 A Type C UL listed required total conductor length must be 10 m or less 4 3 X56 X56 DC Output 4 5 1 2 3 PWR PGND Positive output Negative output Tightening torque 0 8 Nm 7 lbin Use 60 75 C copper conductors only Conductor cross section 2 5 4 mm2 AWG 24 12 Stripping length 10 mm total conductor length must be 1...

Page 8: ...e mm up to M5 257 262 Case degree of protection IP 20 Storage temperature C 25 40 Transport temperature C 25 70 Operating temperature C 0 40 at rated data Relative humidity 95 non condensing Pollution Pollution degree 2 acc EN IEC 61800 5 1 Altitude 2000 m above sea level Max power dissipation W 100 Mounting place Control cabinet with minimum protection class IP54 Mounting position vertical Minimu...

Page 9: ...300 of the nominal load for up to 2 seconds After a power boost longer than 0 5 seconds or if the total boost time in the last 4 seconds was longer than 0 5 seconds the current is limited to the nominal current until a cooldown period has passed The cooldown period can be calculated with Figure 3 Below 0 5 seconds no boost break is necessary Figure 3 Boost time versus required break time ...

Page 10: ...n of Conformity and CE marking IECEE CB SCHEME Ref Certif No CH 11541 USA Canada All products marked with this symbol are tested and listed by Underwriters Laboratories and the production facilities are checked quarterly by an UL inspector This mark is valid for the USA and Canada and eases certification of your machines and systems in these areas File number E316095 UL 61800 5 1 Power Conversion ...

Page 11: ...Installation Guide Power Supply ENG NTI AG LinMot Type S02 72 1000 Page 11 17 ...

Page 12: ...Installation Guide Power Supply ENG Page 12 17 Type S02 72 1000 NTI AG LinMot ...

Page 13: ...Installation Guide Power Supply ENG NTI AG LinMot Type S02 72 1000 Page 13 17 ...

Page 14: ...Installation Guide Power Supply ENG Page 14 17 Type S02 72 1000 NTI AG LinMot ...

Page 15: ...Installation Guide Power Supply ENG NTI AG LinMot Type S02 72 1000 Page 15 17 ...

Page 16: ...duct Item No S02 72 1000 0150 4535 konform ist mit den Anforderungen der Richtlinien is conform to the provisions of directives est conformé aux exigences des directives Low Voltage Directive 2014 35 EU EMC Directive 2014 30 EU gestützt auf die folgenden Normen based on the following standards base aux normes suivants EN 61800 5 1 2007 EN 61000 6 2 2005 Immunity for industrial environments EN 6100...

Page 17: ...ion 41 56 419 91 91 office linmot com Tech Support 41 56 544 71 00 support linmot com Web https www linmot com North South America Headquarters LinMot USA Inc N1922 State Road 120 Unit 1 Lake Geneva WI 53147 USA Sales Administration 262 743 2555 usasales linmot com Tech Support 262 743 2555 usasupport linmot com Web https www linmot usa com Visit https linmot com contact to find a distributor near...

Reviews: