background image

 

Important safety instructions! Please read before connection!

  

 

 

 

RISK OF ELECTRIC SHOCK 
DO NOT OPEN 

ATTENTION: 

To prevent the risk of electric shock, do 

not open the unit under any circumstances.  
 
Refer all maintenance and repair work to a qualified 
workshop or contact your dealer. 
 

The lightning flash symbol warns the user 
of uninsulated voltage and the risk of 
electric shock. 

The exclamation point symbol alerts the 
user to important maintenance and 
operating instructions in the instruction 
manual. 

 

Suitable for indoor use only 

 

 

Read operating instructions 

 

 

This symbol defines the minimum distance 
of the object to be illuminated. 

 
For environmental reasons, please recycle the 

packaging correctly. 

 
A new product can sometimes lead to unwanted odours 

or to minimal smoke development for a short period of 
time. This reaction is normal and disappears after a few 

minutes. 

 
The unit is intended for indoor use only (IP20)! Please 

use the device only in a dry environment. Keep the unit 

away from rain, moisture, direct heat and dust. 
 

In order to avoid condensation in the device, the device 

should adapt to the ambient temperature before start-
up. 

 

Please place the device in a well ventilated place, out of 
the reach of flammable materials or liquids. 

 

Do not cover any ventilation openings as this may 
result in overheating. 

 

Please disconnect the power plug if the unit is not to be 
used for a long period of time or if maintenance work is 

to be carried out. 

 

 

 

The device is designed for a maximum ambient 
temperature of 40° Celsius. 

 

 

 

The device should not be installed by inexperienced 
persons and must be installed in compliance with the 
mechanical and electrical safety regulations in your 
country. 

 

 

 

If the power cord is damaged, it must be replaced 
immediately with an original spare part from the 
manufacturer. 

 

 

 

Make sure that the mains voltage is not higher than the 
voltage indicated on the housing. 

 

 

 

In case of a malfunction of the device, please contact your 
dealer and stop the operation of the device immediately. 

 

 

 

A minimum distance of 1m to flammable materials or 
liquids must be maintained. 

 

 
 

 

OVERHEAD MOUNTING

 

 

The installation may only be carried out by qualified 
personnel. Improper installation can cause serious injury 
and damage. Observe the load limits of the selected 
installation position. 

 

 

 

Make sure that there are no unauthorized persons 
underneath the device during assembly or 
disassembly/maintenance. 

 
 

 

Producer: MUSIC STORE professional GmbH, 
Istanbulstraße 22-26, 51103 Cologne, Germany

 

 

Summary of Contents for Nano Fog 600

Page 1: ...e place the device in a well ventilated place out of the reach of flammable materials or liquids Do not cover any ventilation openings as this may result in overheating Please disconnect the power plug if the unit is not to be used for a long period of time or if maintenance work is to be carried out The device is designed for a maximum ambient temperature of 40 Celsius The device should not be in...

Page 2: ...3 Tel 49 221 8884 0 Fax 49 221 8884 2500 info musicstore de Intended use The product LightmaXX Nano Fog 600 is used exclusively for the generation of artificial fog by vaporizing the filled fog fume The device may only be used for this purpose and in accordance with the operating instructions Other purposes as well as operation under other operating conditions are expressly not intended and can le...

Page 3: ...is used away from open fire Never cover or tape any ventilation slits or the device itself NOTE Operating conditions Due to its structural characteristics the device is designed for indoor use Never expose the device to rain moisture or liquids as this may cause damage Vibrations dirt or sunlight can also cause damage avoid them NOTE Power supply It is essential that you check that the device volt...

Page 4: ... the power supply and then turn it on Wait until the heating element has reached the operating temperature Control is by remote control It is imperative that you ensure that all cables used for commissioning power and control are subject to the applicable regulations and are undamaged Place the product in a safe ventilated place Ensure that untrained personnel do not have access to the product Mai...

Page 5: ...nections and controlls No Description No Description 1 Fluid tank 6 Output remote control 2 Tank cap 7 ON OFF switch 3 Mounting bracket 8 Fuse 4 Locking screw 9 Power cord 5 Nozzle for fog output 10 Tank indicator ...

Page 6: ...icstore de Model Nano Fog 600 Power supply AC 220 240V 50Hz Power consumption 600 Watt Power connections Fixed power cord Heating time approx 2min Fluid consumption max 70ml min Tank 1 1 Liter Output range approx 3 5m Output quantity 14m min Remote control Yes Dimensions without bracket W x D x H 27 x 15 x 11 mm Weight 2 30 Kg Symptom Troubleshooting No function Check the mains connection and your...

Page 7: ...ble materials is always of elementary importance Please complete the packaging after use to the appropriate recyclings Disposal of packaging Ensure that paper packaging plastic material etc are recycled separately Observe the labels and the corresponding regulations Disposal of batteries Batteries do not belong in the garbage Please dispose of batteries in accordance with official regulations at c...

Page 8: ...ENGLISH MS ID LIG0015922 000 01 2019 Notes ...

Reviews: