FSW-2470

 

 

24 10/100BASE-TX + 100Base-FX slot   

Web smart Switch 

 

 

User’s Guide

 

 

Rev.1.00-0505 

 

Summary of Contents for FSW-2470

Page 1: ...LevelOne FSW 2470 24 10 100BASE TX 100Base FX slot Web smart Switch User s Guide Rev 1 00 0505 ...

Page 2: ......

Page 3: ...in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into ...

Page 4: ...tion 6 Rack mounted Installation 6 Power On 7 NETWORK APPLICATION 8 WEB MANAGEMENT 10 About Web based Management 10 Preparing for Web Management 10 System Login 11 Port Status 12 Port Configuration 14 VLAN Setting 15 Trunk Configuration 16 System Configuration 17 Firmware Update 18 Change Password 19 TROUBLESHOOTING 21 TECHNICAL SPECIFICATION 23 STEP BY STEP FIRMWARE UPGRADE 25 ...

Page 5: ...argeted at workgroup department or backbone computing environment Features Conforms to IEEE 802 3 802 3u and 802 3x Equipped with one uplink 100Base FX slot and default button IEEE 802 3x flow control support Flow control on full duplex Back pressure on half duplex Auto MDIX on all ports N way Auto Negotiation Store and Forward switching architecture and no blocking full wire speed 5Gbps switch ba...

Page 6: ...riority and per port provide 2 queues high and low Trunk Support one trunk group and any 10 100TX port can be assigned as trunk member The maximum trunk member can up to 8 ports as one trunk group Firmware Update TFTP firmware upgrade Package Contents Unpack the contents of LevelOne FSW 2470 and verify them against the checklist below 1 X FSW 2470 24 10 100BASE TX 100Base FX slot Web smart Switch ...

Page 7: ...l Four Rubber Feet Rack mounted Kit Power Cord Package Contents Compare the contents of the Switch package with the standard checklist above If any item is missing or damaged please contact your local dealer for service 3 ...

Page 8: ... 24 ports auto negotiation 10 100Mbps Ethernet RJ 45 connectors one slot module and a default button RJ 45 Ports Auto MDI MDIX 24 ports auto negotiation 10 100 Mbps Ethernet RJ 45 connectors Auto MDI MDIX means that you can connect to another switch or workstation without changing straight through or crossover cabling Module Optional 1 port 100FX SC and 1 port 100FX SC 30Km module Reset Button for...

Page 9: ...inks The port is receiving or transmitting data LK ACT Off No device attached Amber The port is operating in Full duplex mode Blinks Collision of Packets occurs in the port FD COL Off In half duplex mode The Description of LED Indicators Rear Panel The 3 pronged power plug is located at the rear Panel of the 24 10 100BASE TX 100Base FX slot Web smart Switch The Switch will work with AC in the rang...

Page 10: ... slot Web smart Switch comes with a rack mounted kit and can be mounted in an EIA standard size 19 inch Rack The Switch can be placed in a wiring closet with other equipment Perform the following steps to rack mount the switch 1 Position one bracket to align with the holes on one side of the switch and secure it with the smaller bracket screws Then attach the remaining bracket to the other side of...

Page 11: ...anel of the Switch The other side of power cord connects to the power outlet The internal power supply of the Switch works with voltage range of AC in the 100 240VAC frequency 50 60Hz Check the power indicator on the front panel to see if power is properly supplied 7 ...

Page 12: ...h are subsequently used to filter and forward all traffic based on the destination address By using Uplink port the Switch can connect with another switch or hub to interconnect other small switched workgroups to form a larger switched network Small Workgroup LevelOne FSW 2470 Web smart Switch can be used as a standalone switch to which personal computers server printer server are directly connect...

Page 13: ...r attached are both connect to the Switch All the devices in this network can communicate with each other through the Switch Connecting servers to the Switch allow other users to access the data on server 9 ...

Page 14: ...ernet Explorer The Web Based Management supports Internet Explorer 5 0 It is based on Java Applets with an aim to reduce network bandwidth consumption enhance access speed and present an easy viewing screen Note By default IE5 0 or later version does not allow Java Applets to open sockets The user has to explicitly modify the browser setting to enable Java Applets to use network ports Preparing fo...

Page 15: ...ternet Explorer 3 Type http and the IP address of the switch Press Enter 4 The login screen appears Login Interface 5 Key in the user name and password The default user name root and password root 6 Click OK then the home screen of the Web based management appears 11 ...

Page 16: ...ort status function you can view all ports current status Link Status green means the port active Gray means the port inactive Speed the port transmitting speed Duplex the port duplex mode Flow Control the port flow control status 12 ...

Page 17: ... Select the port and click Counters button you can see the port counter information as the following figure shown Click Refresh button to reset the counters Click Cancel button will bring the screen back to previous page 13 ...

Page 18: ...negotiation is enabling you can set up the port speed is On or Off Advertise 10M Full when auto negotiation is enabling you can set up the port speed is On or Off Advertise 100M Half when auto negotiation is enabling you can set up the port speed is On or Off Advertise 100M Full when auto negotiation is enabling you can set up the port speed is On or Off Full Duplex Flow Control when auto negotiat...

Page 19: ...n Speed set the port speed is 100M or 10M Duplex set the port in full duplex or half duplex mode Port State enable or disable the port function Close means the port is unusable Open means the port is functional Port Priority Mapping set the port priority level Back Pressure Support enable or disable back pressure function Port configuration interface VLAN Setting The system supports 24 VLAN groups...

Page 20: ...ed group members VLAN Setting Interface Trunk Configuration The system supports only one trunk group The trunk group supports up to 8 port members If the port members are more than 8 it will cause the system abnormal Mark the port number and click Apply button to apply the setting 16 ...

Page 21: ...VLAN group Otherwise the trunk function will not operate System Configuration You can configure the IP subnet mask and gateway The firmware version shown on the screen may vary with the factory firmware release period Click Submit button to apply the new configuration 17 ...

Page 22: ...arch for the Bootp server utility and download it 4 Install the Bootp server utility that you found 5 Run the Bootp server utility and set the boot file direction to where the new firmware is 6 Go to the Firmware Update interface and click Update button to star firmware loading 7 After updated please power off the switch and then power on the switch Please refer to page 25 fir step by step firmwar...

Page 23: ...r the safety The username and password is 8 characters length and must use the alphanumeric integer characters or numbers The system cannot recognize the symbol other than numbers and characters Enter the new username and new password click Apply button to apply the new username and password 19 ...

Page 24: ...Change Password Interface 20 ...

Page 25: ...ection please notice that fiber cable mode and fiber module should be match Faulty or loose cables Look for loose or obviously faulty connections If they appear to be OK make sure the connections are snug IF that does not correct the problem try a different cable Non standard cables Non standard and miss wired cables may cause numerous network collisions and other network problem and can seriously...

Page 26: ...an find possible solutions If the power indicator does turn on when the power cord is plugged in you may have a problem with power outlet or power cord However if the Switch powers off after running for a while check for loose power connections power losses or surges at power outlet If you still cannot resolve the problem contact your local dealer for assistance Cabling RJ 45 ports use unshielded ...

Page 27: ...l CSMA CD Technology Store and forward switching architecture LED Indicators Per unit Power Per port Link Activity Full duplex Collision Module Link Full Duplex Collision TX RX Transfer Rate 14 880 pps Ethernet port 148 800 pps Fast Ethernet port Network Cable 10BASE T 2 pair UTP STP Cat 3 4 5 cable EIA TIA 568 100 ohm 100m 100BASE TX 2 pair UTP STP Cat 5 cable EIA TIA 568 100 ohm 100m Back plane ...

Page 28: ... Supply 100 240 VAC 50 60Hz 3 3V 7A Power Consumption 15 Watt max Operation Temp 0 to 45 32 to 113 Operation Humidity 10 to 90 Non condensing Storage Temp 10 to 70 Dimensions 440 mm W x 120 mm D x 44 mm H EMI FCC Class A CE Safety UL cUL CE EN60950 24 ...

Page 29: ... Copy the TFTP32 folder to the desktop of Windows and set this PC s IP in same subnet as FSW 2470 you would like to update 2 Copy the F W Bin file to TFTP32 folder This section will guide you through the firmware upgrde by using TFTP32 ...

Page 30: ...the PC will be a TFTP server 4 Set TFTP DHCP server information 1 IP pool starting addressÆ any free same subnet IP as TFTP server 2 Size of poolÆ any 3 Boot fileÆ full file name of the F W Bin file 4 MaskÆ same as TFTP server 26 ...

Page 31: ... 5 Login to the web management of FSW 2470 then check the Firmware Update page click the Update button for F W update 6 FSW 2470 s F W is being updating 27 ...

Page 32: ... 7 Click the TFTP server tab to make sure F W Bin file has been transmitted to FSW 2470 completely then press the reset button of the switch 1 minute later 8 New F W is updated successfully 28 ...

Reviews: