background image

RT8kVA and RT11kVA 6U Rack or Tower

Uninterruptible Power Supplies

Product Guide

The RT8kVA and RT11kVA 6U Rack or Tower Uninterruptible Power Supply (UPS) offerings provide

extended power protection with increased efficiency and simplified power management to safeguard high-

availability of System x® and ThinkServer® server environments. With efficiency ratings of up to 98%,

these compact 6U rack or tower designs can help reduce energy usage without compromising

performance or reliability.

The 6U Rack or Tower UPS units can be installed in a data center rack cabinet or can be used as tower

UPS units in office and distributed IT environments where extended power protection is required.

The 6U Rack UPS unit (RT8kVA or RT11kVA) is shown in Figure 1.

Figure 1. RT8kVA or RT11kVA 6U Rack UPS unit (Power module (top) and Battery module (bottom))

Did you know?

6U Rack or Tower UPS units feature Advanced Battery Management (ABM) technology that uses a unique

three-stage charging technique that significantly extends battery service life and optimizes recharge time,

compared to traditional charging methods.

6U Rack or Tower UPS units come standard with the Maintenance Bypass module, which enhances

system availability by providing service continuity during UPS maintenance and upgrades.

6U Rack or Tower UPS units come standard with UPS Manager software that integrates seamlessly with

the major virtualization platforms, which enables you to view and manage your entire power system from

your current dashboard. It also triggers live migration during power outages and avoids data loss by

gracefully shutting down virtual machines and hosts in a cluster if there is an extended power outage.

RT8kVA and RT11kVA 6U Rack or Tower Uninterruptible Power Supplies

1

Summary of Contents for 55948KX

Page 1: ...VA 6U Rack UPS unit Power module top and Battery module bottom Did you know 6U Rack or Tower UPS units feature Advanced Battery Management ABM technology that uses a unique three stage charging technique that significantly extends battery service life and optimizes recharge time compared to traditional charging methods 6U Rack or Tower UPS units come standard with the Maintenance Bypass module whi...

Page 2: ...odule MBP with the hardwired MBP detection cable and two hardwired power cables for connections to the power module s terminal block An accessory kit that contains the following items Rack mount kit Rack installation instructions Tower kit Serial cable 3 7 m 12 ft USB cable Remote On Off ROO and Remote Power Off RPO connector Battery power cable Battery detection cable A documentation kit that con...

Page 3: ...including sequential starting of the installation and optimization of backup time by shutting down non priority systems Automatic date and time adjustment through an NTP server Dual stack IP v4 IP v6 Recording of events and measurements in the card log Data and event logging in the nonvolatile memory Card firmware update through the network 10 100 Mb Ethernet RJ 45 connector with auto negotiation ...

Page 4: ...11kVA 6U Rack or Tower UPS units protect against the following power problems power failures power sags power surges under voltage electrical line noise over voltage frequency variation switching transients and harmonic distortion The RT8kVA and RT11kVA 6U Rack or Tower UPS models offer the following features High efficiency protection delivers more real power Watts in a compact tower or 6U rack d...

Page 5: ...t VA Watts rating 8000 VA 7200 W 8000 VA 7200 W 11000 VA 10000 W 11000 VA 10000 W Efficiency on utility power Online mode Up to 94 5 High efficiency mode Up to 98 Transfer time Online mode 0 ms no break High efficiency mode 10 ms maximum due to loss of utility power Energy Star compliant Yes No Yes No Electrical input Input voltage 200 240 V AC 1 Phase 380 415 V AC 3 Phase 200 240 V AC 1 Phase 380...

Page 6: ...and Power Off Remote On Off and Remote Power Off terminal block connectors Specification RT8kVA 6U Rack or Tower UPS 200 240VAC RT8kVA 6U 3 1 Phase Rack or Tower UPS 380 415VAC RT11kVA 6U Rack or Tower UPS 200 240VAC RT11kVA 6U 3 1 Phase Rack or Tower UPS 380 415VAC Table 3 lists the expected period that the 6U Rack or Tower UPS models operates only on batteries depending on the load Note Battery ...

Page 7: ...mperage power factor voltage frequency input voltage input frequency battery voltage efficiency and power usage Control Displays the battery test reset error state configure load segments clear power usage measurements and restore settings Settings Allows you to change product general parameters and set input and output parameters on off conditions and battery configuration Event log Displays the ...

Page 8: ...or Tower UPS 200 240VAC Figure 5 Rear view of the RT8kVA or RT11kVA 6U Rack or Tower UPS 200 240VAC Figure 6 shows the rear view of the RT8kVA or RT11kVA 6U 3 1 Phase Rack or Tower UPS 380 415VAC RT8kVA and RT11kVA 6U Rack or Tower Uninterruptible Power Supplies 8 ...

Page 9: ...e RT8kVA or RT11kVA 6U 3 1 Phase Rack or Tower UPS 380 415VAC Figure 7 shows the rear view of the 8kVA 11kVA 3U Rack or Tower Extended Battery Module 55949BX RT8kVA and RT11kVA 6U Rack or Tower Uninterruptible Power Supplies 9 ...

Page 10: ...PX 23 kg 51 lb The 8kVA 11kVA 3U Rack or Tower Extended Battery Module has the following physical specifications approximate Height 130 mm 5 1 in Width 441 mm 17 4 in Depth 680 mm 26 8 in Weight 65 kg 143 lb Operating environment The RT8kVA and RT11kVA 6U Rack or Tower UPS units are supported in the following environments Temperature operation 0 40 C 32 104 F with linear derating for altitude Rela...

Page 11: ...its Download the software from the following links Windows http support lenovo com downloads ds111594 Virtual appliance OVF file http support lenovo com downloads ds112919 For up to 100 devices a Silver license can be purchased For up to 600 devices a Gold license can be purchased The following table shows the part number ordering information for each version of the UPM software Table 4 UPM part n...

Page 12: ...Exit Maintenance Mode Yes Yes Yes Advanced Power Actions Virtual Machines Load shedding Shutdown targeted Virtual Machines Migrate Virtual Machines to Target Hosts Shutdown VMware vApp Automate VMware SRM Recovery Plan No Yes Yes Fully virtualized cluster shutdown No Yes Yes OpenStack monitoring and control No No Yes UPM brings managing various power and environmental devices under control through...

Page 13: ...discovery to provide fast installation by automatically detecting devices on the network Mass upgrades firmware which reduces network management card setup and maintenance time UPS Power Protector The UPP software is free to download and use Download it from the following links Windows http support lenovo com downloads ds111596 Linux http support lenovo com downloads ds111595 UPP software facilita...

Page 14: ...that require AC power To determine the best fit UPS for a particular configuration the following needs to be considered Total power load of the hardware that will be connected to the UPS Number and type of outlets required UPS outlet and group limitations for connecting the hardware to the UPS To determine chassis node and server overall power capacities use the Power Configurator tool The tool ca...

Page 15: ...4AX PureFlex System 42U Rack 93634BX PureFlex System 42U Expansion Rack 93634CX PureFlex System 42U Rack 93634DX PureFlex System 42U Expansion Rack Related publications and links For more information about this topic see the following resources Rack UPS product page http shop lenovo com us en systems servers options systemx rack power infrastructure ups Power and Cooling Technical References http ...

Page 16: ...Related product families Product families related to this document are the following Uninterruptible Power Supplies RT8kVA and RT11kVA 6U Rack or Tower Uninterruptible Power Supplies 16 ...

Page 17: ... for use in implantation or other life support applications where malfunction may result in injury or death to persons The information contained in this document does not affect or change Lenovo product specifications or warranties Nothing in this document shall operate as an express or implied license or indemnity under the intellectual property rights of Lenovo or third parties All information c...

Page 18: ...marks of Lenovo in the United States other countries or both Lenovo System x ThinkServer The following terms are trademarks of other companies Linux is a trademark of Linus Torvalds in the United States other countries or both Microsoft and Windows are trademarks of Microsoft Corporation in the United States other countries or both Other company product or service names may be trademarks or servic...