Contents Page

General description / Technical data / Safety instructions .............................................. 2
Care and maintenance / Factory settings / Functional description ................................. 3
Overview of transponder cards ....................................................................................... 4
System components / Package contents / Installation .................................................... 5
Installation variant for internal RFID reader .................................................................... 6
Dimensions............ .......................................................................................................... 7
Getting started and changing batteries / Tips for programming steps ............................ 8
Using the installation card / Programming the master card ............................................ 9
Programming the user cards / Closing & opening ......................................................... 10
Unauthorised transponder cards / Facility Manager function / Emergency opening  .. 11
Deleting individual transponder cards / Deleting all transponder cards ....................... 12
Changing the operating mode ....................................................................................... 13
Deactivating and activating acoustic signals / Resetting to factory settings .................. 14
Battery warning  ............................................................................................................ 15
External power supply / Firmware update  ................................................................... 16
Reordering master and update cards / Troubleshooting ............................................... 17

www.lehmann-locks.com

Operating Instructions

GB

M410 L033-A01 / -A02

BD

A M410 L033-A01 /-A02 2018-04-24 (GB)

L033-A02

L033-A01

Summary of Contents for M410 L033-A01

Page 1: ...rd Programming the master card 9 Programming the user cards Closing opening 10 Unauthorised transponder cards Facility Manager function Emergency opening 11 Deleting individual transponder cards Deleting all transponder cards 12 Changing the operating mode 13 Deactivating and activating acoustic signals Resetting to factory settings 14 Battery warning 15 External power supply Firmware update 16 Re...

Page 2: ...as the scope of items in the system are subject to change without notice CAUTION Please keep the master and update cards as well as the card with the individual service key carefully and securely TECHNICAL SPECIFICATIONS SAFETY PRECAUTIONS U U When replacing the battery make sure that the polarity and position of the battery is correct U U Dispose of used batteries properly U U Do not heat batteri...

Page 3: ...ting modes are available Only the M410 L033 A02 with a spacer is suitable for use on metallic surfaces Please note that the distance between two or more RFID readers must be at least 5 cm This system is not intended for push to open applications If required this needs to be tested on individual basis Lock operating mode Description Assigned use factory settings There is a fixed assignment between ...

Page 4: ...ogrammed for the first time the lock is disabled for the installation card The use of an installation card is optional Master card For complete commissioning a master card must be programmed for both operating modes The master card is required for starting and terminating programming operations This also includes the programming of user cards in Assigned use mode The master card also enables the s...

Page 5: ...5x35 for M410 3 1x battery CR123A 4 Striker plate 5 3x screw 3x13 for striker plate 6 Cable Optional components for RFID reader L033 A01 7 RFID reader L033 A01 8 2x thermoplastic screw 3x20 9 RFID reader housing for internal mounting 10 2x screw 3x13 for RFID reader housing 11 Double sided adhesive tape Optional components for RFID reader L033 A02 12 RFID reader L033 A02 13 2x thermoplastic screw ...

Page 6: ...sible with an external RFID reader Please note the different mounting positions and drilling pattern for the RFID readers RFID reader L033 A01 RFID reader L033 A02 without spacer RFID reader L033 A02 with spacer CAUTION For mounting the RFID reader L033 A02 without spacer please use drill holes of 5 5mm with spacer please use drill holes of 3 5mm Please countersink holes for screwheads Tighten the...

Page 7: ...sing screws by hand and then connect the optical cable to the lock 5 Remove the protective film from the rear side of the adhesive tape Then stick the entire reading unit to the inner side of the door Please position the RFID reader in such a way that you still have access to the micro USB port DIMENSIONS 4 5 1 2 3 RFID reader L033 A01 64 7 25 5 5 2 Ø 40 73 RFID reader L033 A02 RFID reader L033 A0...

Page 8: ...R THE FOLLOWING PROGRAMMING STEPS The last 5 seconds before the shutdown of the programming process are announced by the flashing of a yellow lamp and acoustic signals The visual and acoustic signals are differentiated as follows Optical signals Short flashing Long flashing Acoustic signals Short Long Inserting the battery Battery is inserted correctly in the battery compartment Open the battery c...

Page 9: ...ROGRAMMING THE MASTER CARD Irrespective of the desired operating mode a master card must always be programmed before further programming and operation Only one master card can be programmed per lock The programming of the master card can be carried out when the lock is closed as well as when it is open If the lock is closed after the master card has been programmed the next step must be an emergen...

Page 10: ...e user cards see Closing and Opening P 10 After programming the user cards can open and close the lock Programming user cards Master Hold the master card in front of the reader User Hold the user card in front of the reader The card is accepted and programmed This process can be repeated to program multiple user cards Card is not accepted Master Hold the master card in front of the reader CLOSING ...

Page 11: ...unction the lock opens for 30 seconds and then closes automatically After this automatic closure authorised user cards can continue to be used in Shared use mode as well as in Assigned use mode EMERGENCY OPENING In the event that one or all authorised user cards are currently not available an emergency opening can be effected with the master card Please note that the lock remains open after emerge...

Page 12: ...aster Hold the master card in front of the reader User Hold the user card to be deleted in front of the reader Master Hold the master card in front of the reader DELETING ALL TRANSPONDER CARDS only for Assigned use mode The deleting process can only be carried out when the lock is open Should there be no authorised user card to hand first perform an emergency opening using the master card Deleting...

Page 13: ...t separately from LEHMANN Vertriebs gesellschaft mbH Co KG The cards are for universal use Changing the operating mode Master Hold the master card in front of the reader P1 Mode Hold the programming card No 1 P1 Mode in front of the reader Shared use mode is selected Shared use P1 Mode Hold the programming card No 1 P1 Mode in front of the reader again Assigned use mode is selected Assigned use Ma...

Page 14: ...t mbH Co KG The cards are for universal use Deactivating and activating acoustic signals Master Hold the master card in front of the reader P2 Sound Hold the programming card No 2 P2 Sound in front of the reader The acoustic signals are deactivated Acoustic signals are deactivated P2 Sound Hold the programming card No 2 P2 Sound in front of the reader again Acoustic signals are activated again Aco...

Page 15: ...acement in the event of reduced battery power The battery warning takes place in two phases The settings are saved even without a power supply e g in case of battery replacement or in case the battery should be completely empty Battery replacement should be carried out within 5 minutes Battery warning Phase 1 Before an action can be carried out closing opening programming a battery warning is give...

Page 16: ...ding the charging process U U Please do not perform any further actions until the RFID reader gives an acoustic and a visual signal see Acoustic and visual signals when inserting the battery U U Then open the lock with an authorised transponder card Here you can use either a programmed user card or the master card for emergency opening U U Then carefully disconnect the power bank from the RFID rea...

Page 17: ...d the number of replacement cards you require Transponder card cannot be programmed Possible reasons Storage space is used up Card is not compatible Master card has not yet been programmed Available storage space in the lock is used up Possible reasons 50 user cards have already been programmed in the lock Bolt warning the bolt does not move to the end position Possible reasons Striker plate or lo...

Page 18: ...ck the functions open close with an authorised user card again when the furniture is open If the lock should work properly please check to see if the bolt can extend correctly when the furniture is closed see installation recommendation If you are using an existing user card not from the Lehmann company check to see whether the appropriate write permission has been given for the transponder card L...

Page 19: ...BDA M410 L033 A01 A02 2018 04 24 GB 19 NOTES ...

Page 20: ...A01 A02 2018 04 24 GB 20 LEHMANN Vertriebsgesellschaft mbH Co KG Postfach 26 20 D 32383 Minden Fon 49 571 50 599 0 Fax 49 571 50 599 822 info lehmann locks com www lehmann locks com DIN EN ISO 9001 2008 zertifiziert ...

Reviews: