manualshive.com logo in svg
background image

 www.prolight.co.uk

 STAGE WASH U.V. 36

(order code: LEDJ106)

              

USER MANUAL

Содержание STAGE WASH U.V. 36 LEDJ106

Страница 1: ...www prolight co uk STAGE WASH U V 36 order code LEDJ106 USER MANUAL ...

Страница 2: ...ARE USING THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCK Before your initial start up please make sure that there is no damage caused during transportation Should there be any consult your dealer and do not use the equipment To maintain the equipment in good working condition and to ensure safe operation it is necessary for the user to follow the safety instructions and warning notes written i...

Страница 3: ...ble periodically If the equipment is dropped or damaged disconnect the mains power supply immediately Have a qualified engineer inspect the equipment before operating again If the equipment has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation might damage the equipment Leave the equipment switched off until it has rea...

Страница 4: ...oduction CONTROL FEATURES 2 channel DMX Blackout Dimmer Strobe Features 36 Ultra Bright 1W Ultra Violet LEDs Master Slave functions Sound activated Rugged compact housing Consumption 42W Beam 40 degrees Long life LEDs DMX Channel Summary ...

Страница 5: ...36 is a DMX 512 controllable unit made up of high efficiency and super bright Ultra Violet LEDs The Stage Wash U V 36 will operate in stand alone Master Slave sound activated or via DMX 512 control LED Display Down Button Up Button DMX IN DMX OUT DMX IN DMX OUT DMX IN Mode Button Enter Button ...

Страница 6: ...nd Mode To set the unit in sound mode press the mode button to show the last sensitivity setting between S 00 S 99 on the LED display Now press the ENTER button and use the UP and DOWN buttons to set the sound sensitivity level from 00 99 00 low 99 high DMX mode To set the unit in DMX mode press the mode button to show the last DMX address setting between A000 A255 on the LED display Now press the...

Страница 7: ...st controllers only have a data out terminal DMX Linking DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are co...

Страница 8: ...oid erratic behaviour Using a cable terminator part number CABL90 will decrease the possibilities of erratic behaviour 5 Pin XLR DMX Connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 Pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The Chart below de...

Страница 9: ...Dimensions Length 300mm Width 255mm Height 125mm Weight 3 7 kgs Power AC input 240V 50hz Fuse Main 20mm Glass 2A Fast Blow Control Programming Data input Locking 3 pin XLR male socket Data output Locking 3 pin XLR female socket Protocols DMX 512 USITT DMX channels 2 ...

Отзывы: