Page 1: ...ass by itself Part No 112819 1 Laundrylux 461 Doughty Boulevard Inwood NY 11096 0338 www laundrylux com Service 516 371 0700 Parts 516 271 2000 DAWF0 and DAWS0 SERIES DRYERS D R Y E R I N S T A L L AT I O N M A N U A L ...

Page 2: ...nical instructions which will provide the necessary information concerning the modification of the appliance to the condition of use for the country In accordance with EN ISO 3166 1 the names of countries shall be represented by the following codes GB United Kingdom IE Ireland Retain This Manual in a Safe Place for Future Reference This product embodies advanced concepts in engineering design and ...

Page 3: ...sachusetts If using a ball valve it shall be a T handle type A flexible gas connector when used must not exceed 3 feet WARNING Children should not be allowed to play on or near the dryer s Children should be supervised if near dryer s in operation Under no circumstances should the dryer door switch es lint door switch es or heat safety circuit s ever be disabled Do not modify this appliance The dr...

Page 4: ...cooking oil constitute a fire hazard and should not be placed in a tumble dryer Do not dry mop heads Contamination by wax or flammable solvents will create a fire hazard WARNING Do not use heat for drying articles that contain plastic foam sponge rubber or similarly textured rubber materials Drying in a heated tumbler may damage plastics or rubber and also may be a fire hazard A program should be ...

Page 5: ...___________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ Use this dryer only for its intended purpose drying fabrics The Cool Down Cycle of tumble dryers should be used to reduce the temperature of the items They should not be removed fro...

Page 6: ...ø 2w 60 Hz APPROXIMATE NET WEIGHT 176 lb 79 83 kg APPROXIMATE SHIPPING WEIGHT 198 lb 89 81 kg AIRFLOW 220 cfm 6 23 cmm HEAT INPUT 26 000 Btu hr 6 550 kcal hr EXHAUST CONNECTION DIAMETER 4 10 16 cm NATURAL GAS SUPPLY PRESSURE 6 12 in WC NATURAL GAS MANIFOLD PRESSURE 3 in WC L P SUPPLY PRESSURE 11 in WC L P MANIFOLD PRESSURE 10 5 in WC INLET PIPE CONNECTION 3 8 M N P T VOLTAGE AVAILABLE 208 240V 1ø ...

Page 7: ... Specifications _____________________________________________________________________ NOTE The manufacturer reserves the right to make changes in specifications at any time without notice or obligation TopControl ...

Page 8: ...8 112819 1 Specifications _____________________________________________________________________ Bottom Control Stackable ...

Page 9: ...st Requirements section The dryer must be located in an area where correct exhaust venting can be achieved as noted in this manual refer to Exhaust Requirements section IMPORTANT The dryer should be located where a minimum amount of exhaust ducting will be necessary The dryer must be installed with adequate clearance for air openings into the combustion chamber CAUTION This dryer produces combusti...

Page 10: ...ng out of the top of the washer There are two Feed both harnesses into the bottom of the dryer using the rear cutout hole Do not feed through the coin access funnel hole See diagram Non metered card and non coin installations do not need to interconnect harnesses between the washer and dryer Align the dryer mounting holes over the threaded adapter plate holes The front of the washer and dryer will...

Page 11: ... of the elbows should preferably be 1 1 2 times the diameter of the duct All ductwork should be smooth inside with no projections from sheet metal screws or other obstructions which will collect lint When adding ducts overlap the duct being connected All ductwork joints must be taped to prevent moisture and lint from escaping into the building Back draft dampers must be installed in all commonly d...

Page 12: ...e ductwork must be increased Vertical Venting When vertical dryer venting is used the length of the ductwork from the dryer to the outside exhaust outlet must not exceed 12 feet 3 66 meters The diameter of this ductwork must be 4 inches 10 16 cm Including tumbler dryer elbow connections or elbows used for outside protection from the weather no more than 3 elbows should be used in the exhaust duct ...

Page 13: ...just the autotransformer located near the burner assembly To adjust the autotransformer wiring place the red wire on the appropriate tap HIGH MED LOW of the autotransformer For additional wiring details refer to the electrical diagram located on the inside of the control panel TERM LINE VOLTAGE 60 Hz HIGH 283 249 MED 260 230 LOW 236 208 7 18 12 Electric Models Only All electrically heated dryers m...

Page 14: ... the manufacturer IMPORTANT If connection to this appliance is made with a flexible hose it must be suitable for the appliance category in accordance with national installation regulations of the country of destination and if in doubt the installer must contact the supplier The manufacturer of this appliance does not recommend the use of flexible gas supply line hose An external gas supply shutoff...

Page 15: ...essible for a pressure gauge connection must be installed in the main gas supply line immediately upstream of the dryers IMPORTANT Pipe joint compounds that resist the action of natural L P and butane gases must be used Test all connections for leaks by brushing on a soapy water solution liquid detergent works well WARNING Never test for leaks with a flame Converting from One Family of Gas to Anot...

Page 16: ... and affix this label as close as possible to the dryer s existing dryer rating data label plate Affix L P Conversion Rating Label Addendum P N 114090 as close as possible to the dryer s existing dryer rating data label plate Open all shutoff valves reconnect electrical power to the dryer and test for leaks IMPORTANT Never test for leaks with an open flame Use a soapy water solution or product int...

Page 17: ...onversions done improperly can result in a fire or explosion Gas Pressure Testing For proper operation the gas pressure must be correct consistent and maintained at the gas pressure rates shown on page 15 Provisions are made at the gas valve for taking gas pressure readings There are two types of devices used to measure gas pressure They are the spring mechanical type gauge and the manometer The u...

Page 18: ...elections Each microprocessor controller computer has been preprogrammed by the factory with the most commonly used parameter program selections If computer program changes are required refer to the computer programming manual which was shipped with the dryer Preoperational Instructions __________ IMPORTANT For more detailed information regarding the microprocessor controller computer refer to the...

Page 19: ...e After Each Load Clean the lint screen after each load A clogged lint screen will cause poor dryer performance The lint door is located just below the loading door of the dryer Open the lint door brush the lint off the lint screen and remove the lint Inspect lint screen and replace if damaged Weekly Clean lint accumulation from lint chamber thermostat and microprocessor temperature sensor area WA...

Page 20: ...___________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ______...

Page 21: ..._________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ __________________________________________________________________________________________________...

Page 22: ...Part No 112819 ...