background image

 

 

 

 

 

 

 

     

 

 

 

 

 

 

 

 

 

 

 

 

 

AC EV Charging Statio

 

DOC ID: UM210801.A0 

Wally-1 by 

laScossaElettrica

manuale utente

Summary of Contents for WALLY-1

Page 1: ...AC EV Charging Station DOC ID UM210801 A0 Wally 1 by laScossaElettrica manuale utente ...

Page 2: ...R INSTALLATION AND MAINTENANCE PERSONNEL FAILURE TO READ THIS MANUAL CAREFULLY BEFORE INSTALLATION MAINTENANCE AND OPERATION MAY LEAD TO IMPROPER OPERATION FAILURE TO FOLLOW THE SAFETY NOTES MAY LEAD TO A DANGER OF DEATH INJURY AND DAMAGE TO THE DEVICE LASCOSSAELETTRICA CANNOT ACCEPT ANY LIABILITY FOR CLAIMS RESULTING FROM THIS ...

Page 3: ...TION 10 4 1 General 10 4 2 Block diagram 11 4 3 Product series 11 4 4 Technical specifications 12 4 5 Nameplate 13 5 INSTALLATION INSTRUCTIONS 15 5 1 Transport or movement 15 5 2 Unpacking 15 5 3 Installation preparation 16 5 4 Installation Steps 18 6 OPERATION 20 6 1 Power on 20 6 2 Human machine interface 20 6 3 Configure WiFi network 23 6 4 Start charging 25 6 5 Normally stop charging 25 6 6 Ab...

Page 4: ... LCD Liquid Crystal Display 9 LED Light emitting Diode 10 RFID Radio Frequency Identification 11 CMS Central Management System Manages EVSE and has the information for authorizing users for using its EVSE 12 OCPP Open Charge Point Protocol A standard open protocol for communication between EVSE and a Central System and is designed to accommodate any type of charging technique www openchargeallianc...

Page 5: ...ded to alert the user that severe personal injury or substantial property damage can result if the device is not operated as requested ATTENTION Warning of a danger spot or dangerous situation This sign is intended to alert the user that minor personal injury or material damage can result if the device is not operated as requested CAUTION Warning of electromagnetic field CAUTION Warning of combust...

Page 6: ...dous blast may result Leave no inflammable or explosive substances near the EV Charging station otherwise hazardous blast may result EV Charging station should be installed in a place with no conductive dust and insulation destructive gas or vapor EV Charging station should be installed in a place with no violent vibration and impact for good ventilation mount the charging station vertically The i...

Page 7: ...l of the EV Charging station must be grounded securely otherwise hazardous electric shock may result The lead nose of the charging station must be securely attached or there is a risk of damaging the equipment Leave no metals such as bolts gaskets into the inside of the EV Charging station otherwise hazardous blast and fire may result Main loop terminal of the EV Charging station should be firmly ...

Page 8: ...ging station and immediately stay away from the charging station And then contact the supplier It is strictly prohibited to use the charging station when the charging adapter or charging cables are defective cracked worn broken or the charging cables is exposed If you find any please contact the supplier in time EV can only be charged with the engine off and stationary Do not charge in rainy and t...

Page 9: ...A parameters must be adjusted and matched before operation otherwise property loss may result It is recommended that routine safety inspection visits to charging station be conducted at least once a week Keep the charging connector clean and dry and wipe with a clean dry cloth if soiled ...

Page 10: ...s Part 2 Dimensional compatibility and interchangeability requirements for a c pin and contact tube accessories 3 2 Charging mode According to IEC 61851 1 3 1 9 6 2 3 Mode 3 è il metodo di collegamento tra una EV car tad un AC EV Wallbox connessa permanentemente alla rete elettrica AC Tramite un controllo pilota nel cavo tipo 2 la linea elettrica viene estesa dalla rete all auto La Wallbox fornira...

Page 11: ...nnettore di ricarica Il connettore di ricarica della WALLY risponde allo standard IEC 62196 2 type 2 Fig 3 2 Scopo della WALLY è la ricarica delle auto che rispondono allo standard Tipo 2 descritto nel IEC 62196 2 Type 2 socket Fig 3 2 Diagramma del Tipo 2 socket e plug ...

Page 12: ... utilizzo della WALLY AC EV Wallbox di ricarica da noi prodotta Dimensioni ed immagini in figura Fig 4 1 Fig 4 1 Dimensioni della Wally WALLY fornisce un user friendly HMI per funzioni di controllo bilanciamento e comunicazione WALLY può essere installata in qualsiasi sito come parcheggi casa garage ristoranti etc ...

Page 13: ...r Manual DOC ID UM210801 A0 11 4 2 Diagramma a blocchi Diagramma a blocchi della WALLY mostrato in fig 4 2 Fig 4 2 Diagramma a blocchi della WALLY 4 3 Product series LCD if any Ethernet Wifi LED Main PCBA RFID RCCB Charging Connector ...

Page 14: ...ontrollo di ricarica Locale Plug and charge o strisciare card Remote smartphone APP control 3 Display screen 4 3 inch LCD screen display currente di ricarica tensione energia tempo di ricaricas stato informationi errori etc 4 Indicatori led 4 LED lights indicano 4 stati power connect charging and fault 5 Interfaccia di comunicazione Ethernet RJ 45 interface WiFi 2 4GHz RS 485 Internal debug interf...

Page 15: ...anel Nero Vetro Temperato Cover posteriore Grigio metallico 7 Enclosure rated IP54 4 4 4 Ambient conditions 1 Altitudine 2000m 2 Temperatura di utilizzo 40 75 3 Temperatura operativa 30 55 4 Umidità relativa 95 RH No water droplet condensation 5 Vibrazione 0 5G Nessuna vibrazioni acute 6 Sito installazione Indoor o outdoor buona ventilazione no vicino a fiamme 4 5 Targa Sulla wallbox è applicata u...

Page 16: ...WALLY AC EV Charging Station User Manual DOC ID UM210801 A0 14 Fig 4 3 Nameplate of charging station ...

Page 17: ... urti e danni d La Wally non deve essere trascinata dal cavo o dal connettore 5 2 Disimballaggio 5 2 1 Lista contenuto Nella confezione troverete il seguente materiale 1 Wallbox Wally 2 RFID cards 1 set di staffe per montaggio a muro incluse viti 1 manuale utente 5 2 2 Ispez ione confirma Qundo ci sarà il disimballaggio prestate particolare attenzione ai seguenti punti a Whether the accessories ar...

Page 18: ...s electric shock may result Make sure input power supply is entirely disconnected before wiring otherwise hazardous electric shock may result Operator must always notice safe protection such as wear protective footwear wear goggles otherwise it may be personal injury 5 3 2 Tools for installation Prepare the following tools at least before installing the WALLY AC EV charging station Sr No Tools Nam...

Page 19: ...rging station should be installed in a place with good ventilation no direct sunlight and shelter from wind and rain d In order to ensure good ventilation condition you should mount the charging station vertically and leave enough space e Mounted the WALLY product on the wall is shown in Fig 5 1 Fig 5 1 Mounted the WALLY product on the wall f If you purchase products with floor mounted accessories...

Page 20: ...the wall with the expansion screw which contain in package Fig 5 2 Install the attachment 5 4 2 Step 2 Wiring a Secure mounting Accessories to the Charging station b Remove the cover of Input Terminal Box c Pass the input cable through the Input Cable Interface connect the power cable to the Input Terminal d Reset the cover of input terminal box Input Terminal Box Input Cable Interface Charging ad...

Page 21: ...ls and finally fix the cable If the CMS is to be connected through the network cable put the network cable through the Charging adapter interface then crimp the RJ 45 header and then insert it into the network cable interface 5 4 3 Step 3 Follow the arrow and hold the wallbox Accessories on the attachment Fig 5 4 Hang the wallbox on the attachment 5 4 4 Step 4 Tighten the set screws on the left an...

Page 22: ...RCCB and POWER indicator light is on and the charging station enters the standby state 6 2 Human machine interface 6 2 1 HMI information As shown in Fig 6 1 the M3W U series product is configured with multiple human machine interfaces LED indicators Emergency stop button LCD Charging connector RFID reader Empty charging connector socket Fig 6 1 HMI of M3W U series product ...

Page 23: ...g adapter is properly connected to the vehicle 3 OFF Twinkle OFF OFF Starting 4 OFF OFF Twinkle OFF Charging 5 OFF OFF OFF Alternately Twinkle Fault Get the fault code by the cycle flashing of the fault indicator In any state the Power indicator is twinkle indicating that the charging station is connected to the CMS through the network 6 2 3 LCD if any The LCD with WALLY configuration is a 4 3 inc...

Page 24: ...FID card 6 2 5 Emergency stop button This button is used to stop charging in case of emergency At any time in case of any emergency such as fire smoke abnormal noise water inflow etc on the premise of ensuring personal safety please press this button and immediately stay away from the charging station And then contact the supplier 6 2 6 Charging connector empty socket M3W U series AC EV charging s...

Page 25: ...sull Smartphone WiFi e testate la connessione Internet tramite il router WIFI collegandovi ad esso d Installare l APP esptouch nel vostro smartphone Note esptouch for iOS download link https apps apple com cn app espressif esptouch id1071176700 esptouch for Android download link https github com EspressifApp EsptouchForAndroid re leases download v1 1 1 esptouch apk IOS Android e Aprire esptouch AP...

Page 26: ...ina configurazione WiFi g Quando tutti gli indicatori inizieranno a lampeggiare la configurazione WIFI sarà completata mostrando sul display la dicitura Successful con indicati rete WIFI e Password WiFi per qualche secondo Al termine dell impostazione della rete wifi sulla Wally verificare che sia presente l icona segnale WIFI Successivamente installare APP WE E Charge Creare nuovo account e logga...

Page 27: ...p charging a There are two normal stoppages for plug and charge charging station first automatic stoppage with full charge and second manual stoppage b Operation of manual stoppage press the unlock button of the remote key of the electric vehicle the vehicle will stop charging requires the support of the electric car if the charging is not stopped press the button of the adapter again as shown in ...

Page 28: ...gency such as fire smoke abnormal noise water inflow etc on the premise of ensuring personal safety please press the red Emergency Stop button of the charging station to stop the charging process b Forced fault stop A fault stop initiated by the onboard charger of vehicle c Automatic fault stop A fault stop initiated by the charging station ...

Page 29: ...lash slowly once and fast twice Emergency stop Fault code 12 The E stop button is pressed after troubleshooting rotary the button and reset it the fault state will exit Fault light flash slowly once and fast 3 times Input a under voltage Fault code 13 Check that the input cable is reliably connected that the parent grid is properly connected and that the grid voltage is abnormal Fault light flash ...

Page 30: ...t code 23 The device is damaged and needs to be returned to the factory for repair Fault light flash slowly twice and fast four times Leakage detection circuit fault Fault code 24 The device is damaged and needs to be returned to the factory for repair Fault light flash slowly twice and fast five times Earth fault Fault code 25 Charging station is not grounded input power cable needs to be checked...

Page 31: ...d in case of the following situations Equipment failure caused by not following the user s manual Equipment damage caused by fire flood abnormal voltage etc Equipment damage caused by using the product for abnormal functions Equipment damage caused by foreign matter entering Equipment damage caused by other human external factors 5 The service fee shall be calculated according to the actual cost I...

Reviews: