Explosion Proof LED Drop Light 

Instruction Manual 

Do not attempt operation until you are familiar with all warnings, precautions, and procedures outlined within this 
instruction sheet.

 

Read carefully before operating. Retain these instructions for future reference. 

WARNING: 

USER  SHOULD  BE  TRAINED  IN  THE  PROPER  USE  AND  MAINTENANCE  OF  THIS  DEVICE.  IF  WIRING  OR  LAMP  REPLACEMENT  INSTRUCTIONS  ARE  NOT 
FOLLOWED EXACTLY, THE HANDLAMP MAY NOT BE SUITABLE FOR THE HAZARDOUS LOCATION INVOLVED. WHEN HANDLAMP IS CONNECTED TO A POWER 
SOURCE  IN  HAZARDOUS  AREA,  PLUG  AND  MATCHING  RECEPTACLE  MUST  BE  SUITABLE  FOR  HAZARDOUS  LOCATION  INVOLVED.  WHEN  HANDLAMP  IS 
CONNECTED TO POWER SOURCES OUTSIDE OF HAZARDOUS AREA, STANDARD DUTY PLUGS AND RECEPTACLES MAY BE USED.  
 

STANDARD PLUG AND TRANSFORMER MUST ONLY BE CONNECTED TO A RECEPTACLE LOCATED OUTSIDE THE HAZARDOUS AREA! 

IMPROPER USE OF THIS HANDLAMP, ASSOCIATED PLUG, RECEPTACLE, AND CORD CAN LEAD TO SERIOUS INJURIES OR DEATH TO PERSONNEL.  
 

PERIODIC INSPECTION OF THE HANDLAMP AND CORD IS NECESSARY.

 

THE  CORD  MUST  BE  ROUTINELY  CHECKED  FOR  CUTS,  BREAKS,  OR  ANY  SEVERE  ABRASIONS,  AND  IF  ANY  ARE  FOUND,  THE  CORD  MUST  BE  REPLACED 
BEFORE RESUMING USE OF THE HANDLAMP.  
 
THE GLOBE IS MADE OF TEMPERED GLASS. IF THIS GLASS BECOMES SCRATCHED OR CHIPPED IT SHOULD BE REPLACED IMMEDIATELY.  

OPERATION 

1. 

Position light head in desired location using swivel hook. 

2. 

Run cable, transformer, and plug 

OUTSIDE HAZARDOUS AREA

3. 

Attach power cord from transformer to 

Voltage: 120V AC

 

compatible 

receptacle. If no light output, check status of inline GFCI and power source. 

 

WARNING:

 

Check  product  label  for  correct  voltage!  Failure  to  comply  could 

result in damage to the fixture which may not be covered by warranty. The bulb itself 
runs on low voltage specified upon purchase.

 

 

The 

LED lamp in this hand lamp is “instant-on” and will illuminate once power is supplied. 

GROUND-FAULT CIRCUIT INTERRUPTER (GFCI)

 

In the event of a ground fault, a GFCI will trip and quickly stop the flow of electricity to 
prevent serious injury. 

Definition of a ground fault:

 

Instead of following its normal safe path, electricity passes through a person's body to 
reach the ground. For example, a defective appliance can cause a ground fault. 

A GFCI receptacle does 

NOT 

protect against circuit overloads, short circuits, or shocks. 

For example, you can still be shocked if you touch bare wires while standing on a non-
conducting surface, such as a wood floor. 

NOTE:

 

GFCI's contain a lockout feature that will prevent RESET if: 

• There is no power being supplied to the GFCI. 
• The GFCI is miswired due to reversal of the LINE and LOAD leads. 
• The GFCI cannot pass its internal test, indicating that it may not be able to provide 
protection in the event of a ground fault.

 

 

 