background image

IL2412

ENVIROZONE-TSTAT

GAS GRIDDLE

Commercial

224ZT, 236ZT, 248ZT, 260ZT, 272ZT

Installation and 

Operation 

Instructions

2M-W1785  Rev. C  4/23/15 

272ZT

Summary of Contents for 224ZT

Page 1: ...IL2412 ENVIROZONE TSTAT GAS GRIDDLE Commercial 224ZT 236ZT 248ZT 260ZT 272ZT Installation and Operation Instructions 2M W1785 Rev C 4 23 15 272ZT ...

Page 2: ...ION MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT WARNING RISK OF FIRE OR ELECTRIC SHOCK DO NOT OPEN WARNING TO REDUCE THE RISK OF ELECTRICAL SHOCK DO NOT REMOVE CONTROL PANEL NO USER SERVICABLE PARTS INSIDE REPAIRS SHOULD BE DONE BY AUTHORIZED SERVICE PERSONNEL ONLY NOTICE Using any part other than genuine Lang factory supplied parts relieves the manufacturer o...

Page 3: ...kly Cleaning 12 Burner Air Shutter Adjustment 12 Calibration 13 Troubleshooting Symptoms Possible Causes Test 14 Wiring Diagram 15 17 Exploded View Parts List 18 23 PROBLEMS QUESTIONS or CONCERNS Before you proceed consult you authorized Lang service agent directory or Call the Lang Technical Service Parts Department at 314 678 6315 NOTICE Service on this or any other Lang appliance must be perfor...

Page 4: ... 260ZT 60 24 135 000 135 000 260ZTD 30 175 000 175 000 272ZT 72 24 162 000 162 000 272ZTD 30 210 000 210 000 SPECIFICATIONS AND INFORMATION MODEL NUMBER GRILL SURFACE OVERALL SQUARE INCHES OF GRIDDLE NUMBER OF BURNERS NUMBER OF CONTROLS NUMBER OF GREASE DRAWERS CLEARANCE FROM NON COMBUSTIBLE SURFACES WEIGHT WIDTH DEPTH SIDES BACK BOTTOM ACTUAL SHIPPING 224ZT 24 23 552 2 2 1 0 5 4 INCH LEG 255 300 ...

Page 5: ...ture value can be set at 200 F 93 C Technical Griddle operates on either Natural gas or Propane which must be specified when ordering It is shipped with a power cord and plug attached Floor space required is 30 76 20cm Deep and width is 2 ft 3ft 4ft 5ft or 6ft depending on actual model number The griddle weighs 255 336 435 530 610 lbs depending on actual model number Griddle Gas and Voltage Specif...

Page 6: ...me The griddle can now be removed from the skid THE UNIT IS EXTREMELY HEAVY FOR SAFE HANDLING INSTALLER SHOULD OBTAIN HELP AS NEEDED OR EMPLOY APPROPRIATE MATERIALS HANDLING EQUIPMENT SUCH AS A FORKLIFT DOLLY OR PALLET JACK TO REMOVE THE UNIT FROM THE SKID AND MOVE IT TO THE PLACE OF INSTALLATION ANY STAND COUNTER OR OTHER DEVICE ON WHICH GRIDDLE WILL BE LOCATED MUST BE DESIGNED TO SUPPORT THE WEI...

Page 7: ...or proper operation and servicing AIR SUPPLY Make certain not to obstruct the flow of combustion and ventilation air Provisions for adequate air supply must be furnished The legs supplied with the unit must be installed Make certain that air intake openings in the bottom of the appliance are not obstructed They are essential for proper combustion and operation of the appliance EXHAUST CANOPY It is...

Page 8: ...old for connecting a manometer Correct manifold pressures are 5 inches water column for natural gas 10 inches water column for propane When replacing the plug in the manifold a pipe joint compound or sealant should be used that is resistant to the action of liquid petroleum gas Initial adjustments are the responsibility of the installer and are not chargeable to Lang Manufacturing International Af...

Page 9: ...ch to STANDBY Seasoning the Griddle Plate non chrome only Set the temperature dials to 300 F 148 C Observe the burners through the opening at the top of the control panel When the burners go OFF apply a thin coat of high grade non salted vegetable oil to the griddle surface Rub the oil into the griddle surface with the flat side of a spatula or a towel Recoat any dry spots that appear then wait tw...

Page 10: ...R CLEAN IMMEDIATELY TO AVOID THE DANGER OF SLIPS OR FALLS CAUTION SUGGESTED TIMES AND TEMPERATURES PRODUCTS TEMPERATURE F C TIME MIN HAMBURGER 350 F 176 C 2 patties per LB 6 to 8 4 patties per LB 4 to 6 6 patties per LB 3 to 4 STEAKS 1 2 to 3 4 inch thick cooked medium 375 F 190 C 5 to 7 3 4 to 1 inch thick cooked medium 8 to 10 Lamb Chops 350 F 176 C 6 to 8 Pork Chops 6 to 8 Salmon 6 to 8 Halibut...

Page 11: ... griddle When reloading the griddle first use the griddle surface on which a previous load was not placed This will insure you the proper griddle temperature SEQUENCE OF OPERATION Power On When the griddle is connected to 115 Volt power and the switch is turned ON the spark module for each section starts sparking When the individual pilot tubes ignite and the pilot flame is verified the spark modu...

Page 12: ...odate differences in gas and elevation To adjust the air shutters loosen the set screw holding the air damper to the burner near the gas inlet Adjust the air mixture until the burner flame just flickers on the burner Lift off or yellow flame indicates improper shutter adjustment Periodically inspect and clean the air shutters to insure complete combustion Griddle Care Chromium Surfaces It takes ve...

Page 13: ...EP WATER AND SOLUTIONS OUT OF CONTROLS NEVER SPRAY OR HOSE CONTROL CONSOLE ELECTRICAL CONNECTIONS ETC CAUTION MOST CLEANERS ARE HARMFUL TO THE SKIN EYES MUCOUS MEMBRANES AND CLOTHING PRECAUTIONS SHOULD BE TAKEN TO WEAR RUBBER GLOVES GOGGLES OR FACE SHIELD AND PROTECTIVE CLOTHING CAREFULLY READ THE WARNING AND FOLLOW THE DIRECTIONS ON THE LABEL OF THE CLEANER TO BE USED NOTICE Never leave a chlorin...

Page 14: ...r on pilot iginition control not plugged in properly Check all connections on pilot ignition control Spark wire not connected to pilot ignition controller or ignitor Check spark wire orange wire connections Pilot iginition control failed Replace pilot ignition control Ignitor sparks but does not light pilot tube No gas to griddle Check gas connection and shut off valve Gas supply not purged of air...

Page 15: ...TE 2M 61122 W54 WIRE DIAGRAM 224ZT NO TIMERS N A 12 2 11 JMM TITLE R 6 5 4 3 2 1 6 5 4 3 2 1 GRN WHT BLK GRN BRN BRN BRN BRN YEL YEL ORG BLK BLK BLK WHT WHT WHT BLK WHT BRN BRN GRN YEL WHT BLK ORG WHT BLK KEY POWER CORD ON OFF SWITCH PILOT SOLENOID BURNER SOLENOID THERMOSTAT PILOT IGNITION MODULE PILOT IGNITOR WIRE NUT 1 2 5 6 7 8 3 4 4 4 5 5 5 6 6 7 7 8 8 8 8 4 3 2 1 3 REV DATE ECO DESCRIPTION OF...

Page 16: ...E 2M 61122 W56 WIRE DIAGRAM 248ZT NO TIMERS N A 12 8 2011 JMM TITLE R 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 GRN WHT BLK GRN BRN BRN BRN BRN YEL YEL ORG BLK BLK BLK WHT WHT WHT BLK WHT YEL BRN BRN BRN BRN GRN YEL WHT WHT BLK BLK ORG WHT WHT BLK BLK BLK WHT GRN BRN YEL BRN ORG KEY POWER CORD ON OFF SWITCH PILOT SOLENOID BURNER SOLENOID THERMOSTAT PILOT IGNITION MODULE PILOT IGNITOR WIRE NUT 1 2 5 6 7 ...

Page 17: ...N MODULE PILOT IGNITOR WIRE NUT 1 2 5 6 7 8 3 3 3 4 4 4 4 4 4 5 5 5 5 5 5 6 6 7 7 7 8 8 8 8 8 8 6 4 3 2 1 REV DATE ECO DESCRIPTION OF CHANGE DR THIS DRAWING CONTAINS INFORMATION CONFIDENTIAL TO STAR MFG INT L INC NO REPRODUCTION OR DISCLOSURE OF ITS CONTENTS IS PERMITTED TOLERANCE UNLESS NOTED xxx 015 ANGLES 1 REVISIONS PART NO MODEL NO MATERIAL FINISH STAR MANUFACTURING INTERNATIONAL INC 10 SUNNE...

Page 18: ...Z1785 ENVIROZONE TSTAT GAS GRIDDLE MODEL ENVIROZONE THERMOSTAT GAS GRIDDLE SK2564 Rev A 5 17 2014 1 2 3 4 5 6 7 8 9 12 13 14 15 15 27 28 29 26 timer units 16 17 18 19 20 21 22 23 20 19 24 25 2 See Detail A ...

Page 19: ...LB HOLDER EZONE 224ZT 3 236ZT 4 248ZT 5 260ZT 6 272ZT 5 2C 20202 08 8 WSHR PLT 5 16 LOCK SPLIT 224ZT 12 236ZT 16 248ZT 20 260ZT 24 272ZT 6 K9 141 171 W2 2 GRIDDLE BURNER ASSY 224ZT 3 236ZT 4 248ZT 5 260ZT 6 272ZT K9 141 171 3W2 2 GRIDDLE BURNER ASSY 30 DEEP 224ZTD 3 236ZTD 4 248ZTD 5 260ZTD 6 272ZTD 7 K9 141 181 2 BAFFLE UNDER BURNER 224ZT 3 236ZT 4 248ZT 5 260ZT 6 272ZT K9 141 182 1 BAFFLE BETWEE...

Page 20: ...F ALL 18 2I 05 07 0013 1 BOOT SWITCH ALL 19 2R W498 2 2 KNOB RED METAL INSERT 188 224ZT 3 236ZT 4 248ZT 5 260ZT 6 272ZT 20 2M W728 W4 2 LABEL CONTROL 200 550F 224ZT 3 236ZT 4 248ZT 5 260ZT 6 272ZT 21 2T 30402 07 2 STAT ADJ 550o 48 C T 224ZT 3 236ZT 4 248ZT 5 260ZT 6 272ZT 22 K9 50303 18 1 GRS BCKT ASSY 141 FRT GTR 224ZT 236ZT 2 248ZT 260ZT 272ZT K9 142 251 1 GREASE BUCKET ASSY 224ZTD 236ZTD 2 248Z...

Page 21: ...2M Z1785 ENVIROZONE TSTAT GAS GRIDDLE SK2565 Rev A 4 23 2015 DETAIL A Manifold Removed for Clarity 1 4 5 6 7 8 10 17 11 16 13 14 15 12 16 2 3 ...

Page 22: ...3 260ZT 272ZT 3 2V 80501 04 1 GAS REG 3 4X3 4 CLS I NAT 2V 80501 05 GAS REG 3 4X3 4 CLS II LP 4 2J 80302 W1 1 IGNITOR ELECTRODE 224ZT 2 236ZT 248ZT 3 260ZT 272ZT 5 2C Z5883 10 10 24 X 1 2 FZA SCREW 224ZT 18 236ZT 20 248ZT 28 260ZT 30 272ZT 6 K9 141 146 2 PROBE GUARD SUPPORT 224ZT 3 236ZT 4 248ZT 5 260ZT 6 272ZT 7 2F 80002 W19 1 TUBE LIGHTER 25 DIA 224ZT 2 236ZT 248ZT 3 260ZT 272ZT 8 2K 70101 51 1 ...

Page 23: ...ntity Description Application 12 2C 20102 12 22 SCRW PHD ST 10 32X3 8 224ZT 29 236ZT 38 248ZT 44 260ZT 48 272ZT 13 2V 80502 W07 3 VALVE SOLENOID 1 8 NPT 224ZT 5 236ZT 6 248ZT 8 260ZT 9 272ZT 14 2K 45300 5 FITTING 3 8CC X 1 8NPT 224ZT 8 236ZT 10 248ZT 13 260ZT 15 272ZT 15 K9 141 156 W4 2 VALVE BRACKET RIGHT 248ZT 260ZT 3 272ZT K9 141 156 W5 1 VALVE BRACKET LEFT 224ZT 2 236ZT 248ZT 260ZT K9 141 156 ...

Page 24: ...LP 3 236ZT LP 4 248ZT LP 5 260ZT LP 6 272ZT LP Y9 80400 18 2 ORIFICE HOOD 1065 36 224ZTD NAT 3 236ZTD NAT 4 248ZTD NAT 5 260ZTD NAT 6 272ZTD NAT Y9 80400 13 2 ORIICE HOOD 0892 43 224ZTD LP 3 236ZTD LP 4 248ZTD LP 5 260ZTD LP 6 272ZT LP ni 2K 70104 03 1 FLEXIBLE TUBE 3 8OD X 8 224ZT 3 236ZT 4 248ZT 260ZT 6 272ZT ni 2K 70104 04 1 FLEXIBLE TUBE 3 8OD X 12 224ZT ni 2K Z4921 3 BURNER TUBE FLEX 3 8 OD 2...

Reviews: