background image

Manual 

Wind Sensors EFFICIENT Modbus (14579)

(14579) EFFICIENT Modbus

Manual

EFFICIENT Modbus · The Efficient Solution

Are you cost-conscious but still demanding when it comes to 

your wind measurement data? 
Then the EFFICIENT Modbus sensors are your ideal solution. 
With this sensor concept, high-quality materials meet func-

tional design. EFFICIENT sensors also impress with their 

high accuracy, effortlessly simple mounting principles and 

corrosion-resistant materials. EFFICIENT sensors save time 

and money, but not the quality of your measurement data. 

•  Proven sensor technology
•  Very good starting values
•  Simple mast mounting 

POSSIBLE APPLICATIONS

► 

Professional meteorological applications

► 

Building automation

► 

Photovoltaic systems

► 

Industrial meteorology

1

Содержание EFFICIENT Modbus

Страница 1: ...or concept high quality materials meet func tional design EFFICIENT sensors also impress with their high accuracy effortlessly simple mounting principles and corrosion resistant materials EFFICIENT se...

Страница 2: ...t a certified disposal company for electronic waste Outside the EU Please follow the regulations in your country regarding the appropriate disposal of waste electronic equipment Content 1 Initial oper...

Страница 3: ...the upper wind speed sensor is 0 1 to 0 5 m above the upper edge of the lower wind direction sensor 2 Principles of installation Because the installation takes place in a danger ous height the assembl...

Страница 4: ...s the North mark on the sen sor must be aligned with the geographical north direction You have to turn the marking exactly over the marking at the sensor shaft When you have aligned the marks you may...

Страница 5: ...Manual Wind Sensors EFFICIENT Modbus 14579 14579 EFFICIENT Modbus Manual 7 Wiring diagram 5...

Страница 6: ...Manual Wind Sensors EFFICIENT Modbus 14579 14579 EFFICIENT Modbus Manual 8 Dimensional drawings Accessories optional 14567 U6 Mast adapter Id No 32 14567 006 000 6 3 10 mm...

Страница 7: ...or Values of 9999 indicate an internal sensor error 9 3 Standard configuration Default Baud rate 19200 Baud Byte frame 8E1 1 start bit 8 data bits 1 parity bit even parity 1 stop bit RTU Sensor addres...

Страница 8: ...ent request and the previous request The maximum range of a period is 1 hour Recalling the average value of a minimum maximum and average group will erase the appropriate registers Retrieve the values...

Страница 9: ...egister 8 Checksum OK 8BCA LEN 19 Transmission Response Source Slave 13 Dest Master Function Read Holding Register 3 Func Desk Byte count 16 Data 30 30 2E 31 36 34 38 30 2E 30 30 31 31 33 30 00 Checks...

Страница 10: ...stics Measuring ranges 0 360 0 7 50 m s Accuracy 2 0 5 m s at 0 7 5 m s and 2 FS at 5 02 50 m s Resolution 1 0 02 m s Starting value 0 7 m s 0 7 m s Interface RS485 RS485 Protocol Modbus RTU Modbus RT...