background image

LACAVA

®

6630 West Wrightwood Ave. Chicago, IL 60707  tel 773 637 9600   fax 773 637 9601   [email protected]   www.lacava.com 

Owner’s Manual

ZOOM Thermostatic Mixing Valve

Item:  EX25A

Important: Keep this manual for future technical assistance and/or replacement parts.  Please read the instructions within 

the booklet carefully prior to installation.  LACAVA recommends that this fixture be installed by a professional plumber and 

will not be held responsible for any damage caused by improper installation.  It is the responsibility of the homeowner to 

ensure that this fixture complies with all local plumbing codes.  Please see the Terms & Conditions found within this

booklet for additional information.  For technical assistance please contact 773-637-9600.

Importante: Guarde este manual para futura asistencia técnica y / o piezas de repuesto. Por favor, lea las instrucciones 

en el folleto cuidadosamente antes de la instalación. LACAVA recomienda que este aparato sea instalado por un técnico 

y no se hace responsable de los daños causados por una instalación incorrecta. Es la responsabilidad del propietario 

garantizar que este aparato cumpla con todos los códigos de plomería locales. Por favor, consulte nuestros Términos y 

Condiciones que se encuentran en este folleto para información adicional. Para obtener asistencia técnica, por favor 

contacte a: 773-637-9600. 

Table of Contents/Contenido:

Page 2:  Product Specifications/Especificaciones de Producto

Page 3:  Parts Breakdown/Desglosamiento de Partes

Page 4 :  Installation Instructions/Instrucciones de Instalación

Page 6:  Cleaning & Care/Cuidado y Limpieza

Page 7:  Warranty/Garantía

Page 8:  Terms and Conditions/Términos y Condiciones

Features:

-Wall-mount integrated thermostatic mixing valve

-Brass construction with Vernet cartridge  

-

Water

 fl

ow rate : 6 GPM at 43.5 PSI

-I

ncludes built-i

n fi

lters and check valves

-

Standard water temperature range 68-118

-Flexible installation

Summary of Contents for EX25A

Page 1: ...ucciones en el folleto cuidadosamente antes de la instalación LACAVA recomienda que este aparato sea instalado por un técnico y no se hace responsable de los daños causados por una instalación incorrecta Es la responsabilidad del propietario garantizar que este aparato cumpla con todos los códigos de plomería locales Por favor consulte nuestros Términos y Condiciones que se encuentran en este foll...

Page 2: ...ducto Note Drawings provided herein are meant to give the user an idea of the product and are not made to scale The sizes in inches are rounded up to the nearest 1 16 OUTLET F 1 2 G COLD M 1 2 G HOT M 1 2 G 2 1 8 54 4 1 4 115 3 5 8 90 1 1 2 39 6 5 8 170 100 ...

Page 3: ...losamiento de Partes Note Please reference this sheet and the corresponding part number when requesting parts Nota Por favor referirse a esta pagina y la parte correspondiente cuando ordene partes Parts R039 thermorstatic cartridge ...

Page 4: ...onnection 2 x M 1 2 G OUT connection F 1 2 G Vernet part R039 6 GPM at 43 5 PSI 68 1180F Installation Diagram Technical Specifications Mount and install components according to the diagram Features included built in filters and check vavles SENSOR FAUCET FIXTURE SINKTOP COLD WATER SUPPLY HOT WATER SUPPLY BATTERY CONTROL BOX THERMOSTATIC MIXING VALVE ...

Page 5: ...rkings The red button is a safety stopper for 100ºF it needs to be pressed down to bypass the safety limit and turn the knob to a higher temperature Max temperature limit for mixed water output is 118ºF Recommended hot water supply is 150ºF and should not exceed 185ºF Recommended supply water pressure is 43 5 PSI range limits 14 80 PSI 1 Make connection to control box and hot and cold water supply...

Page 6: ...o enjoy our products for many years to come Para mejores resultados por favor cuide des este producto de acuerdo con las siguientes instrucciones Sólo utilice agua tibia y un detergente suave es decir el jabón para lavar la vajilla para la limpieza Si se utiliza otro limpiador revise la etiqueta para asegurarse de que es seguro para el uso del material para su limpieza y siempre prueba en un área ...

Page 7: ...AVA LLC proporciona una Garantía Limitada de por Vida en sus grifos Esto garantiza que cualquier grifo instalado en una aplicación residencial no presentara defectos en el material o de fabricación mientras que el consumidor original posea su casa Cualquier producto instalado en una aplicación comercial está cubierto bajo garantía por un año LACAVA garantiza que todos los otros productos no presen...

Page 8: ...ther it was our error If we verify it was our mistake we will promptly ship the missing item s to the purchaser by standard ground at our cost RETURN POLICIES If the product is not satisfactory for any reason different from defects it can be returned to LACAVA LLC up to 30 days from the shipping date after obtaining a Return Goods Authorization RGA valid for 60 days If the product is not returned ...

Page 9: ...agente chofer de la compañía cualquier alteración visible en el empaque En el caso que falten artículos también hay que informar a LACAVA y enviar todos los documentos relacionados con un plazo de 24 horas a partir de la fecha de entrega Vamos a abrir una investigación interna y verificar el recuento de inventario para determinar si fue un error de nuestra parte Si nos damos cuenta que fue nuestro...

Reviews: