background image

TYPE 9101                                               07/2014                                                        1 

 
 
 

 

 
 
 
 
 
 
 
 
 

 

 

 
 
 
 

TYPE 9101 

 
 
 
 
 
 
 
 
 
 

OPERATION & MAINTENANCE  

MANUAL 

 

INSTALLATION MANUAL 

 
 

SOLID FUEL                  

RANGE COOKER

 

Summary of Contents for TYPE 9101

Page 1: ...TYPE 9101 07 2014 1 TYPE 9101 OPERATION MAINTENANCE MANUAL INSTALLATION MANUAL SOLID FUEL RANGE COOKER...

Page 2: ...TYPE 9101 07 2014 2...

Page 3: ...forbidden to use the appliance if it is damaged unfit for its function Any contravention of the operating conditions may cause damage to some parts of the appliance It is recommended not to overload t...

Page 4: ...ummer mode 6 kW 6 kW winter mode 6 kW 6 kW Efficiency with NHO 73 3 Average flue gas temperature with NHO 275 C Flue gas mass flow rate with NHO 8 3 g s Average concentration of CO with NHO with O2 13...

Page 5: ...s or from the top by means of a hole in the Hob Top Fig 1 and 5 The hotplate lid is packaged separately behind the rear side of the appliance for ease of transportation After the appliance has been un...

Page 6: ...of increased room of the combustion chamber should be used Combustion then takes place on the lower grate which can be handled using a lever Figure 3 Raking Raking must be done so the unburned fuel fa...

Page 7: ...e graphic representation of the control is made using triangles and the lever under the symbol means slow burning air supply is closed and contrariwise the lever below the symbol means fast burning ai...

Page 8: ...m steel The front of the hob top above the combustion chamber is especially intended for fast cooking while the rear part has a lower temperature and is suitable for slow cooking and keeping meals war...

Page 9: ...recommends that their range cooker should be covered by the uninsulated lid only after the cooker ceased its operation That means when the food is being cooked on the hob and fuel is still being adde...

Page 10: ...air rose let fire burn out Fire in the chimney do not use water to extinguish the fire close all of the air intakes cover the chimney if possible contact a qualified chimney sweep service to evaluate...

Page 11: ...cap and to attach the flue branch without the ring and use the delivered blank cover to close the rear outlet A chimney with a sufficient draught is absolutely essential for correct appliance operati...

Page 12: ...l The protective baffle plate shall overlap the protected material up to the nearest wall ceiling made of a fireproof material however not less than 300 mm at the upper side and 150 mm at the lateral...

Page 13: ...TYPE 9101 07 2014 13 Flue gas ducting connection to the chimney valid for Czech Republic correct wrong Figure 6...

Page 14: ...ove installation and operation instructions for the appliances primarily comply with the Czech regulations and may not comply fully to individual national regulations at place of installation and use...

Page 15: ...TYPE 9101 07 2014 15...

Page 16: ...1 07 2014 16 Producer KVS EKODIVIZE a s Plant Dvorce Opavsk 272 793 68 Dvorce u Brunt lu CZECH REPUBLIC Telephone 420 554 797 111 Fax 420 554 745 500 E mail prodej dvorce kvs ekodivize cz www kvs ekod...

Reviews: