background image

G 17, Bharat Industrial Estate, T. J. Road, Sewree (W), 

Mumbai - 400 015. INDIA. 

Sales Direct :

 (022) 24156638, 27754546

Tel. :

 (022) 24124540, 24181649, 27750662, 27750292

Email :

 [email protected] 

Website : 

www.kusamelectrical.com 

®

LIST OF PRODUCTS

¬

 Digital Multimeter                    

¬

 Digital AC & AC/DC Clampmeter

¬

 AC Clamp Adaptor                  

¬

 AC/DC Current Adaptor

¬

 Thermo Anemometer               

¬

 Thermo Hygrometer

¬

 Distance Meter                        

¬

 Digital Lux Meter

¬

 Network Cable Tester              

¬

 Power Factor Regulator

¬

 Earth Resistance Tester           

¬

 Digital Panel Meters

¬

 DC Power Supplies                 

¬

 High Voltage Detector

¬

 Calibrators                               

¬

 Gas Analysers

¬

 Frequency Counter                  

¬

 Function Generator

¬

 Phasing Sticks                         

¬

 Battery Tester

¬

 Waterproof Pen Testers           

¬

 Solar Power Meter

¬

 EMF Detector

¬

 Wood, Paper & Grain Moisture Meter

¬

 Transistorised Electronic Analog & Digital Insulation   

    Resistance Testers(upto 10 KV)

¬

 Digital Sound Level Meter & Sound Level Calibrator

¬

 Digital contact & Non-contact Type Tachometer

¬

 Digital Non-contact (infrared) Thermometer

¬

 Maximum Demand Controller/Digital Power Meter

¬

 Digital Hand Held Temperature Indicators

®

®

AN ISO 9001:2015 COMPANY

MODEL - KM 60-T

OPERATION MANUAL

TRUE RMS AUTORANGING 

DIGITAL MULTIMETER

6.000

DC

V

SELECT

HOLD

MAX/MIN

REL

RANGE

FUSED

FUSED

CAT III 600V

10secMAX

10A

MAX

600mA

750V DC

1000V DC

10A

COM

V

W

HzmA

m

A

out

AUTO POWER OFF

TRUE RMS

OFF

V

V

~

NCV

W

Hz

%

A

mA

~

~

~

m

A

out

!

Summary of Contents for KM 60-T

Page 1: ...s Frequency Counter Function Generator Phasing Sticks Battery Tester Waterproof Pen Testers Solar Power Meter EMF Detector Wood Paper Grain Moisture Meter Transistorised Electronic Analog Digital Insu...

Page 2: ...TRMS DIGITAL MULTIMETER MODEL KM 60 T TABLE OF CONTENTS TITLE PAGE NO I Safety II Electrical Specifications III Troubleshooting IV Instrument Layout V Test Certificate VI Warranty 01 02 03 19 23 24...

Page 3: ...battery driven The instrument uses a large screen LCD display boost power supply even in the 2 3V low battery edge it can guarantee the backlight high brightness the table is easy to carry is a vast n...

Page 4: ...s Accuracy Resolution Input Impedance 10MW Overload Protection 6V range is 550V DC or AC peak The rest is 1000V DC or 750V AC Peak Maximum input voltage 750V AC RMS or 1000V DC The specific operation...

Page 5: ...it 3 When measuring high voltage circuit pay special attention to avoid electric shock 4 After completing all measuring operations disconnect the test leads from the circuit under test 06 50 00 D A SE...

Page 6: ...00mA 250V Speed Glass Fuse DC CURRENT mA 600 mA 6000 mA 0 1 mA 1 mA 1 2 rdg 10dgts Range Accuracy Resolution 08 The specific operation is as follows 1 Insert the black test lead into the COM socket In...

Page 7: ...n the range switch to the corresponding DC AC mA gear trigger SELECT to select AC m A and then put the meter into the circuit under test The measured current value and the current polarity of the red...

Page 8: ...0 1 mA 1 mA 1 2 rdg 10dgts Range Accuracy Resolution 12 highest range then according to the display value to the corresponding file such as the screen display 0L that has exceeded the range needed to...

Page 9: ...rst turn off the power then disconnect the test leads the measured circuit connection Especially to high current measurement 6 It is forbidden to input more than 36V DC 25V AC Voltage between the curr...

Page 10: ...0 nF 6 mF 60 mF 600 mF 30 mF 6 mF 15 NOTE 1 When measuring low resistance the table will bring the internal resistance in order to obtain accurate readings you can firstly record the short circuit val...

Page 11: ...e 3 Please test the capacitor capacity before the capacitor should be fully disharged to prevent damage to the fuse and instrumentation 4 Unit IF 1000mF 1mF 1000 F 1uF 1000nf 1nF 1000p 18 Overload Pro...

Page 12: ...ELECT HOLD MAX MIN REL RANGE FUSED FUSED CAT III 600V 10secMAX 10A MAX 600mA 750V DC 1000V DC 10A COM VWHzmA mA out AUTO POWER OFF TRUE RMS OFF V V NCV W Hz A mA mA out 1 2 3 4 5 6 7 8 9 20 The operat...

Page 13: ...mA out AUTO POWER OFF TRUE RMS OFF V V NCV W Hz A mA mA out NCV MEASUREMENT 22 If your instrument does not work the following method can help you solve the general problem if the fault still can not b...

Page 14: ...OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE KUSAM MECO SHALL NOT BE LIABLE FOR ANY SPECIAL INDIRECT INC...

Reviews: