Configuration tool for:

 IFC 100 / 300 (with Pactware)

 BATCHFLUX 5500 C (with BatchMon Plus)

 IFC 010 / 090 / 110 and BATCHFLUX 5012 C / 5015 C (with ImoMon Plus)

USB ADAPTER PLUS

USB ADAPTER PLUS

USB ADAPTER PLUS

USB ADAPTER PLUS

Quick Start

Quick Start

Quick Start

Quick Start

© KROHNE 06/2014 - 4003748601 - QS USB_Adapter_Plus R03 en

Summary of Contents for USB ADAPTER PLUS

Page 1: ...UX 5500 C with BatchMon Plus IFC 010 090 110 and BATCHFLUX 5012 C 5015 C with ImoMon Plus USB ADAPTER PLUS USB ADAPTER PLUS USB ADAPTER PLUS USB ADAPTER PLUS Quick Start Quick Start Quick Start Quick Start KROHNE 06 2014 4003748601 QS USB_Adapter_Plus R03 en ...

Page 2: ... 2 www krohne com 06 2014 4003748601 QS USB_Adapter_Plus R03 en USB ADAPTER PLUS 1 General description 3 2 Operation 4 2 1 IFC 100 4 2 2 IFC 300 5 2 3 BATCHFLUX 5500 C 6 2 4 Converters with ImoCom 12 3 Notes 13 ...

Page 3: ...Optionally you receive a set of connection cables connectors for connection to BATCHFLUX 5500 and old ImoCom type converters Signal converter Cable Software IFC 100 and IFC 300 Standard cable dubox 2x3 pole dubox 2x4 pole or IR interface cable Pactware DTM GDC drivers BATCHFLUX 5500 C Optional cable M12 5 pole dubox 2x4 pole Optional T connector M12 5 pole BatchMon Plus BATCHFLUX 5500 C with statu...

Page 4: ...00 signal converter Needed software GDC driver IFC 100 HART DTM Pactware configuration tool Figure 2 1 Connection of adapter to the GDC bus of the IFC 100 1 Connection room of IFC 100 2 Cable 2x3 pole 2x4 pole 3 USB Adapter Plus INFORMATION All relevant tools are on the CD and on the website of the manufacturer Connect the USB connector to your PC start the relevant program and follow the instruct...

Page 5: ... the GDC bus of the IFC 300 1 Connection room of IFC 300 2 Cable 2x3 pole 2x4 pole 3 USB Adapter Plus with IR interface cable Figure 2 3 Connection of adapter to the IR interface of the IFC 300 1 Display of IFC 300 2 IR Interface cable 3 USB Adapter Plus INFORMATION All relevant tools are on the CD and on the website of the manufacturer Connect the USB connector to your PC start the relevant progr...

Page 6: ...c cables notice the items 2 3 and 5 in the illustration below Figure 2 4 Connection of adapter to the BATCHFLUX 5500 C 1 24 V supply to be provided by customer 2 T connector optional M12 5 pole M12 8 pole for BATCHFLUX 5500 C with status output 3 BATCHFLUX 5500 C connector M12 5 pole M12 8 pole for BATCHFLUX 5500 C with status output 4 USB Adapter Plus standard 5 Optional cable M12 5 pole 2x4 pole...

Page 7: ... hardware found starts Choose Not now click 1x on Next Screen Hardware opens click 2x on Continue If hardware is detected click on Finish Message shows Hardware can be used Start the BatchMon Plus program once Close the program and start it again In the menu the function On line processing is now enabled The menu of the BATCHFLUX 5500 C is given on the next pages INFORMATION All relevant tools are...

Page 8: ...of flow meter size in box 1 1 3 For Table choose from pull down menu in box 1 1 4 C1 1 5 GK selection GK GKL For GK value is shown in box 1 1 6 For GKL value is shown in box 1 1 7 C1 1 8 Coil resistance 10 220 Ω Configured can be changed C1 1 9 Field frequency 1 6 2 line frequency Choose from pull down menu 1 1 10 Select settling Standard predefined Manual 1 1 11 Settling time 0 001 0 25 s Manual ...

Page 9: ...descriptions C2 1 Hardware C2 1 0 Hardware Frequency output Pulse output C2 1 1 Terminals D Program frequency output in submenu 2 2 0 1 Program pulse output in submenu 2 2 0 2 C2 2 Frequency output if selected in 2 1 0 hardware C2 2 1 Pulse shape Symmetric Fixed Automatic default C2 2 2 Pulse width 5E 5 2 s C2 2 3 100 pulse rate 0 01 10000 Hz C2 2 4 Range min 1E 30 1E 30 m3 s Manual input C2 2 5 R...

Page 10: ...ow flow cutoff 0 10 s Manual input C2 3 Status output not available in BATCHFLUX 5500 C Standard version C2 3 1 Mode Off error flow direction default C2 3 2 Invert signal Off default on No Function subfunction Settings descriptions C3 1 Units C3 1 1 Volume flow l s l min l h m3 s m3 min m3 h ft3 s ft3 min ft3 h gal s gal min gal h lG min lG h free unit When you choose free unit two additional boxe...

Page 11: ...s per seconde C4 2 Sensor values C4 2 1 Flow velocity C4 2 2 DC voltage electrode 2 C4 2 3 DC voltage electrode 3 C4 2 4 Electronic temperature C4 2 5 Field current settling time C4 2 6 Field current resistance C4 2 7 Status sensor C4 2 8 Status starting phase C4 2 9 Status warnings C4 2 10 Status fatal C4 2 11 Status field current C4 2 12 Coil temperature C4 2 13 Conductivity C4 3 Information C4 ...

Page 12: ... 3 IFC 090 signal converter 4 IFC 110 signal converter 5 USB Adapter Plus 6 Optional cable 1x5 pole connector 2x4 pole connector CAUTION Please note that net Framework 2 0 is installed before installation part of Windows XP service pack 2 The ImoCom cable 1x5 pole connector 2x4 pole connector is available as an optional package INFORMATION All relevant tools are on the CD and on the website of the...

Page 13: ...NOTES 3 13 USB ADAPTER PLUS www krohne com 06 2014 4003748601 QS USB_Adapter_Plus R03 en ...

Page 14: ...3 NOTES 14 USB ADAPTER PLUS www krohne com 06 2014 4003748601 QS USB_Adapter_Plus R03 en ...

Page 15: ...NOTES 3 15 USB ADAPTER PLUS www krohne com 06 2014 4003748601 QS USB_Adapter_Plus R03 en ...

Page 16: ...nalysis products Products and systems for the oil gas industry Measuring systems for the marine industry Head Office KROHNE Messtechnik GmbH Ludwig Krohne Str 5 47058 Duisburg Germany Tel 49 203 301 0 Fax 49 203 301 103 89 info krohne com KROHNE 06 2014 4003748601 QS USB_Adapter_Plus R03 en Subject to change without notice The current list of all KROHNE contacts and addresses can be found at www k...