Multipurpose 

Injection Training 

Arm

LM-074

Instruction Manual

Thank you for purchasing the LM-074 Multipurpose Injection Training Arm.
Please read this instruction manual carefully to ensure correct use of the
product, and store it in a safe place for easy access.

 

KOKEN CO., LTD. 

1-4-14 Koraku, Bunkyo-ku, Tokyo 112-0004 JAPAN 
URL:http://www.kokenmpc.co.jp 
E-mail:[email protected] 

C-1-938-2-03-02

Summary of Contents for LM-074

Page 1: ...074 Multipurpose Injection Training Arm Please read this instruction manual carefully to ensure correct use of the product and store it in a safe place for easy access KOKEN CO LTD 1 4 14 Koraku Bunkyo ku Tokyo 112 0004 JAPAN URL http www kokenmpc co jp E mail customer kokenmpc co jp C 1 938 2 03 02 ...

Page 2: ...10000 ...

Page 3: ...uld be replaced with new parts as needed 5 The IV opisthenar blood vessel tube and blood vessel tube degrade over time Check the degree to which they have degraded before use If they are overly degraded please replace them 6 Use of thicker needles will shorten the life of the simulated blood vessels and injection sites 7 When not in use store the model away from direct sunlight and ultraviolet lig...

Page 4: ...tion 6 Care for Hypodermic Injection Parts 7 Intramuscular Injection Configuration 8 Set up for Intramuscular Injection 9 Care for Intramuscular Injection Parts 10 IV Injection Configuration 11 Set up for IV Injection 12 Care for IV Injection 13 Replacement of the blood vessel tube blood vessel connector and IV opisthenar blood vessel tube 14 Specifications ...

Page 5: ...ot be reproduced with the previous model Features Silicone is used in the skin and other main parts so the look feel and puncture sensation are similar to those of a real human body which enables more realistic practice Since four different techniques can be practiced with this single model use of several models as in the past is no longer necessary and set up and clean up re storage times are red...

Page 6: ...odermic injection sponge 1 Intramuscular injection gel bag 1 Intramuscular injection sponge 1 Acromial part 1 Arm skin hand 1 Arm skin forearm 1 Arm skin upper arm 1 Stand 1 Irrigators 2 Pinch cock 2 Drainage tube 1 Elbow rest 1 Baby powder 1 Simulated blood 500ml 1 Syringe 50 ml 1 Hose clamps 2 Instruction Manual 1 Storage bag 1 ...

Page 7: ...When practicing techniques other than IV injection or when storing the Training Arm cover the hook with the tube When left uncovered the hook may be deformed or damage the storage bag 1 Pull the stand pole upright 2 Push the pole down until the base of the pole contacts the seat 3 Turn the knob screw to fasten the pole Protective tube Do not discard Height adjustable hook Tighten Loosen Knob screw...

Page 8: ...6 4 Hypodermic Injection Configuration Stand Drainage tube Upper arm skin Acromial part Hypodermic injection site Hypodermic injection sponge Main body ...

Page 9: ...on sponge in place 2 Insert the hypodermic injection site into the acromial part installed in the main body 3 Apply baby powder to the upper arm skin and position on the main body Affix hook and loop fasteners on one side Set skin in place while aligning the skin and point of the elbow on the main body Affix the remaining hook and loop fasteners ...

Page 10: ...ing from the main body insert it into the hole in the upper portion of the pole until the flange on the joint makes contact with the pole 5 Put the joint into the groove labeled SC on the main body Joint Flange Final assembled configuration ...

Page 11: ...rotation is opposite that of the human body Use caution as rotating the Training Arm in the incorrect direction may cause damage 7 Pull back the skin and attach the drainage tube to the drainage tube connector on the main body Place the tip of the drainage tube into a drainage receptacle ...

Page 12: ...he pole the main body can be removed by raising slightly and then pulling 2 Take off upper arm skin and remove hypodermic injection site and hypodermic injection sponge 3 Squeeze gently to remove any fluid remaining in the hypodermic injection site and sponge 4 Dry moisture remaining in all components Insufficient drying may lead to mold After drying always apply baby powder If this is not done th...

Page 13: ...11 7 Intramuscular Injection Configuration Stand Drainage tube Upper arm skin Acromial part Intramuscular injection gel bag Intramuscular injection sponge Main body ...

Page 14: ...ge and set it in the acromial part 2 Set the acromial part in the main body 3 Apply baby powder to the intramuscular injection gel bag and then place the injection site on the main body 4 Set the upper arm skin in place in the same way as for hypodermic injection See 5 Setup for Hypodermic Injection 3 ...

Page 15: ...ng from the main body insert it into the hole in the upper portion of the pole until the flange on the joint makes contact with the pole 6 Insert the joint into the groove labeled IM on the main body Joint Flange Final assembled configuration ...

Page 16: ... connector on the main body as for hypodermic injection Place the tip of the drainage tube into a drainage receptacle See 5 Setup for Hypodermic Injection 7 9 The intramuscular injection setup is now complete When performing IV injections after first practicing with the intramuscular injection site drain and dispose of the fluid remaining in the intramuscular injection gel bag before practicing th...

Page 17: ... 3 Squeeze gently to remove the fluid remaining in the intramuscular injection gel bag and sponge 4 Dry moisture remaining on or in all components Insufficient drying may lead to mold After drying always apply baby powder If this is not done the skin and injection site may stick together and make set up difficult the next time the Training Arm is used 5 Wipe off fluid remaining on the main body If...

Page 18: ... body Stand Pinch cocks Hose clamps IV opisthenar bloodvessel tube IV injection site Hand skin Forearm skin IV opisthenar blood vessel tube Blood vessel connector Blood vessel tube Connector Gel bag Tube connector IV injection site Blood vessel tube IV opisthenar blood vessel tube IV opisthenar blood vessel tube Blood vessel connector Blood vessel tube Connector Gel bag Tube connector IV injection...

Page 19: ...l not to pull too far If pulled too far the spring protecting the tube will be stretched If the connection is not firm leakage may occur Confirm that the fit is solid When attaching the IV injection site grasp the respective connectors insert the connector on the side with the spring and turn in the direction shown in the diagram about 45 until it stops Do not grasp the gel bag portion of the inje...

Page 20: ...excessive force is used 3 After applying baby powder to the forearm skin place this skin on the main body Wrist cover Affix the remaining hook and loop fasteners Affix one side of the hook and loop fasteners and arrange so that the skin is aligned with the contour of the elbow Place the forearm skin over the main body Set the opisthenar blood vessel tube in the groove so that it is not pinched by ...

Page 21: ...lace on the main body 5 Insert the joint protruding from the main body into the hole in the lower portion of the stand pole until the flange makes contact with the pole Cover the hand portion of the main body with the hand skin Affix with hook and loop fasteners ...

Page 22: ...tting the irrigator connector on the end of the irrigator lower to the stand Insert the end of the irrigator firmly and deeply into the irrigator connector Not inserting the end of the irrigator firmly enough may result in leakage of simulated blood Slide the hose clamp in the direction indicated above then fasten the connector ...

Page 23: ...m the tube toward the connector to start the circulation of simulated blood When the irrigator above is emptied of simulated blood hold the Push button down while reversing the upper and lower height adjustable hook Push button Height adjustable hook 8 The setup for IV injection is complete ...

Page 24: ...imulated blood container to a drainage receptacle fill the syringe with water and wash the inside of the blood vessel tube using the same technique as in 3 above Do not press the syringe rapidly This may push air or simulated blood into the IV injection site If that happens use a syringe with a needle to suction out the air or simulated blood 6 Remove the forearm skin and IV injection site and was...

Page 25: ...ge may occur Confirm that the insertion is solid Blood vessel connector 1 Remove the old blood vessel tube from the blood vessel connector and insert the new blood vessel tube deeply into the blood vessel connector If the insertion is not firm leakage may occur Confirm that the insertion is solid IV opisthenar blood vessel tube 1 Remove the old IV opisthenar blood vessel tube from the blood vessel...

Page 26: ...24 14 Specifications Length Width Height Weight Arm main body Approx 63 cm Approx 10 cm Approx 11 cm Approx 3 kg Stand Approx 60 cm Approx 27 cm Approx 68 cm Approx 2 kg ...

Reviews: