1271693-T01-F

Installation Guide

A

leutian

W

ate

r S

o

f

tene

r S

e

r

ies

K-96025T-PS515-01R/K-96025T-PS528-01R
K-96025T-PS511-01R/K-96025T-PS522-01R

TM

KOHLER CHINA INVESTMENT CO., LTD

NO.158, JIANG CHANG SAN ROAD,

JING'AN DISTRICT, SHANGHAI, PRC

POST CODE: 200436

(

)

158

200436

©

©

Copyright Kohler China Investment Co., Ltd.

*

*

Summary of Contents for Aleutian K-96025T-PS511-01R

Page 1: ...oftener Series K 96025T PS515 01R K 96025T PS528 01R K 96025T PS511 01R K 96025T PS522 01R TM KOHLER CHINA INVESTMENT CO LTD NO 158 JIANG CHANG SAN ROAD JING AN DISTRICT SHANGHAI PRC POST CODE 200436 158 200436 Copyright Kohler China Investment Co Ltd ...

Page 2: ...umbing professionals authorized by Kohler If pressure exceeds 100 psi 689 kPa install a pressure reducing valve Please consult plumbing professionals authorized by Kohler for water pressure measurement For cold water use only Temperature Range 5 38 C This softener must be protected from freezing which can cause cracking of the pipe and water leakage Drain this softener when room temperature drops ...

Page 3: ...uirements of the Sanitary Standard for Hygienic Safety and Function Evaluation on Treatment Devices of Drinking Water General Device 2001 2001 Outlet Water Requirement Inlet Water Requirement Municipal Tap Water GB5749 Company Name Address Kohler China Investment Co Ltd No 158 Jiang Chang San Road Jingan District ShangHai PRC 158 Actual Production Factory Address Canature Health Technology Group C...

Page 4: ...ittings Suited to the type of installation not include Silicone lubricant Consumable Materials Cubic Pellet Salt formulated specifically for water Softeners Note Regardless of what type of salt is used we recommend the Brand of China National Salt Industry Corporation Salt in China Safety Glasses Assorted Screwdrivers Pipe Wrench Adjustable Wrench Pipe Welding Device Pipe Cutter Drill Pencil Towel...

Page 5: ...eferenced on request for warranty repair or replacement Location Space Requirements Allow at least 6 inches 15cm behind the unit for plumbing and drain lines and 1 1 meters above for service access and filling the salt container Floor Surface Choose an area with solid level floor free of bumps or irregularities Bumps cracks stones and other ir regularities can cause the salt storage tank bottom to...

Page 6: ...n an inside location to protect from moisture Properly ground to conform with all governing codes and ordinances 1 5 AC12V 50Hz Drain Facilities Choose a nearby drain that can handle the rated drain flow floor drain sink or stand pipe NOTE Waste connections or drain outlets shall be designed and constructed to provide for connection to the sanitary waste system through an air gap of two pipe diame...

Page 7: ... 3 1 2 O Assembly Clip 6m Male Thread Adapter Kit Bypass Valve Assembly Aleutian Control Vavle Body Assembly Fig 3 3 The bypass allows the softener to be isolated from the water service line if service is necessary while still providing water to the home The bypass valve can be connected with P N 1271709 male thread adapter kit Shipped with each softener is a 3 4 adapter Refer to Figure 4 and the ...

Page 8: ...e before cutting into the plumbing Flooding could result if not done CAUTION When making sweat connections use care to keep heat away from the plastic components Damage to these components might result otherwise 7 Drain Line connection Route a length of 1 2 drain line from the drain elbow to the drain Drain elbow see figure5 Fasten the drain line to the elbow with the clamp Secure the drain line t...

Page 9: ...at the installation site are closed Direct the drain line discharge into a bucket where flow can be observed Open the main supply valve Initiate an immediate regeneration to move the control into the BACKWASH position When in the BACKWASH position slowly turn the bypass on allow the media tank to fill slowly until water flows from the drain line When flow to drain is established open the bypass fu...

Page 10: ... long E Other Add the salt and start a manual regeneration immediately Turn off the by pass valve or replace the seal See solution No 3 Set the related parameters again shorten the regeneration cycle time Contact Kohler service A Inlet pressure is too low B Eductor and eductor screen is blocked C Brine line is blocked D Brine line air leaks E Set wrong salt amount parameter Increase pressure to mo...

Page 11: ...tton to enter and exit the menu Press the or button to select a parameter Press and hold the button for 5 seconds to enter the manual regeneration interface Press the or button to change the value Press the button to save the setting Press the or button to select other parameters Follow the above steps to change other parameters Press the button to exit settings You can only change the flashing pa...

Page 12: ...isplay Calendar Clock Mode Meter Mode Meter Immediate Meter Delay Meter Override Screen shows Current Time Last Regeneration day Regeneration Mode the Remaining Days of next regeneration the Capacity Remaining of next regeneration and current Flow Rate Numbers of blue bar represent the Remaining Days at Calendar Clock mode Numbers of blue bar represent the Capacity Remaining the Flow Rate at Meter...

Page 13: ...E default is 02 00 2 If you choose IMMEDIATE the valve will regeneration immediately Note The regeneration mode METER IMMEDIATE has no Delay choice here When regeneration started the screen will display 1 02 00 2 When Brine Remaining time reaches zero or any button is operated valve will be advanced to next cycle position Backwash and screen will display When the valve reaches position screen will...

Page 14: ...he desired setting item Press the button to enter the setting item Current date and current time setting Current date and current time can be set in Time setting item Setting method Press the or button to move the cursor to the desired parameter Press the button to let the parameter flashing Press the or button to change the value Press the button to confirm and save the setting parameter stop fla...

Page 15: ...ursor to the desired parameter Press the button to confirm and save the setting and display returns to main page Water Hardness and People number setting Hardness of municipal water and how many people use water can be selected in Hardness People setting item Press the or button to move the cursor to the desired parameter Press the button to confirm and save the setting and display returns to main...

Page 16: ...iday to let the valve clean the media during your holiday Advanced Settings Automatic Calculate mode and Manual Settings mode can be selected in the Advanced Settings item The key regeneration parameters Capacity Refill Time etc can be calculated in the Automatic Calculate mode Press and hold the button for 5 seconds to enter the Advanced Setting item 5 Note Regeneration Days Backwash duration and...

Page 17: ...lows Calendar Clock Meter Immediate Meter Delayed Meter Override Manual Settings mode s page under different regeneration mode is as follows Calendar Clock Meter Immediate Meter Delayed Meter Override Regen Mode Four Regeneration modes can be selected to meet different installation environment ...

Page 18: ... reaches zero this is the most common setting When the volume remaining reaches zero the system will initiate regeneration at the next preset regeneration time when the volume remaining reaches zero the system will initiate regeneration at the next pre set regeneration time If the days between regeneration are reached before the volume remaining reaches zero the system will override the meter sett...

Page 19: ...hrough the bed and out to the drain Brine time controls the length of time for the unit to draw regeneration brine for softeners from the brine tank and slowly rinse the media tank Rinse time controls the length of time to give the tank a final rinse from the top to the bottom in order to remove any residual brine from the resin Refill time controls the length of time which the brine valve will op...

Page 20: ...o be erased and changed back to the default settings System Information Press the or button to inquire some information of valve by entering System Information item In Total Regenerations and Peak Flow Rate page press and hold button for 5 seconds can reset the value to zero 5 ...

Page 21: ...572 X Indicates that at least one of the homogeneous substance in the material composition is below the high limits of the current requirements in GB T 26572 The product service life for environment protection is 10 years Kohler Company will specify product service life based on product characteristics The product service life for environment protection is only effective when the product is used a...

Page 22: ...1271693 T01 F 2021 3 31 ...