Page 1: ...KOBE Range Hoods Brillia Series Model No RAX2130SQB 1 30 RAX2136SQB 1 36 RAX2142SQB 1 42 RAX2130SQB WM 1 30 RAX2136SQB WM 1 36 RAX2142SQB WM 1 42 INSTALLATION INSTRUCTIONS AND OPERATION MANUAL ...

Page 2: ...an do the installation IF THERE IS ANY PROBLEM 1 DO NOT INSTALL THE UNIT AND KEEP ALL ORIGINAL PACKAGING MATERIAL 2 Have your original invoice as proof of purchase and product serial number ready 3 Call 1 877 BUY KOBE 289 5623 or e mail to info koberangehoods comto report the problem NO RETURN NO REFUND NO EXCHANGE IF 1 PRODUCT HAS BEEN INSTALLED 2 KNOCK OUT HOLES HAVE BEEN PUNCTURED 3 MISSING ORI...

Page 3: ...NANCE 12 SPECIFICATIONS 13 MEASUREMENTS DIAGRAMS 14 PARTS LIST 16 CIRCUIT DIAGRAM 20 TROUBLE SHOOTING 21 WARRANTY 22 PRODUCT REGISTRATION 24 READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING A L L W I R I N G M U S T B E D O N E B Y A P R O F E S S I O N A L A N D I N A C C O R D A N C E W I T H N A T I O N A L A N D L O C A L E L E C T R I C A L C O D E S ...

Page 4: ...eatment negligence or any other circumstances beyond the control of KOBE RANGE HOODS authorized agents Any repair carried out without the supervision of KOBE RANGE HOODS authorized agents will automatically void the warranty KOBE RANGE HOODS will not be held responsible for any damages to personal property or real estate or any bodily injuries whether caused directly or indirectly by the range hoo...

Page 5: ...you still smell gas call the Gas Company and Fire Department right away CAUTION 1 For general ventilation use only Do not use to exhaust hazardous or explosive materials and vapors 2 To reduce the risk of fire use only metal ductwork Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney to prevent back drafting 3 Follow the heating equipment manufacturer s...

Page 6: ...lia Range Hood 1 B Warranty Registration Card 1 C Instructions Manual WEBSITE D Baffle Filter x 2 30 hood x 3 36 42 hood E 6 Round Plastic Collar 1 A B C D Pre installed E Pre installed FOR MORE INFORMATION PLEASE VISIT OUR WEBSITE www KOBERangeHoods com OR CONTACT KOBE RANGE HOODS AT 626 775 8880 For the operation manual please refer to our website KOBERangehoods com ...

Page 7: ...nstructions Manual WEBSITE D Baffle Filter x 2 30 hood x 3 36 42 hood E 6 Round Plastic Collar 1 F Duct cover Mounting Bracket 1 G Duct Cover 1 H Screws Package 1 A B C D Pre installed E Pre installed F G H FOR MORE INFORMATION PLEASE VISIT OUR WEBSITE www KOBERangeHoods com OR CONTACT KOBE RANGE HOODS AT 626 775 8880 3 16 x 3 8 8PCS For the operation manual please refer to our website KOBERangeho...

Page 8: ...or to Counter Top Standard 36 C Preferred Height of Counter Top to Hood Bottom Minimum 26 to 30 D Height of Hood E Height of the Cabinet FOR WALL MOUNT WITH OPTIONAL DUCT COVER TABLE 2 A Height of Floor to Ceiling B Height of Floor to Counter Top Standard 36 C Preferred Height of Counter Top to Hood Bottom Minimum 26 to 30 D Height of Hood E Height of Duct Cover F D F Height of the Hood Installati...

Page 9: ...Y SHARP EDGES PLEASE WEAR PROTECTIVE GLOVES IF REMOVING ANY PARTS FOR INSTALLING CLEANING OR SERVICING NOTE BE CAREFUL WHEN USING ELECTRICAL SCREWDRIVER DAMAGE TO THE HOOD MAY OCCUR Installation Contents UNDER THE CABINET WALL MOUNT 7 9 ...

Page 10: ...ng reference on Page 14 to measure and create access opening for electrical wires and exhaust under the cabinet Hood Installation CAUTION USE HAND TOOLS ONLY DO NOT OVER TIGHTEN SCREWS IT MAY CAUSE DAMAGE TO THE HOOD CAUTION If moving the cooking range is necessary to install the hood turn off the power in an electric range at the main electrical box SHUT OFF THE GAS BEFORE MOVING A GAS RANGE And ...

Page 11: ...ICAL CODES BEFORE CONNECTING WIRES SWITCH POWER OFF AT SERVICE PANEL AND LOCK SERVICE PANEL TO PREVENT POWER FROM BEING SWITCHED ON ACCIDENTALLY If hood is operating normally connect three wires black white and green to house wires and cap with wire connectors Store wires in the wiring box Install Uninstall Accessories 6 Place baffle filters underneath the hood Figure 7 Final Assembly 7 Turn power...

Page 12: ...oss framing lumber for secure installation Using references on Table 2 and measurements on page 14 15 decide the level of the lumber Refer to Figure 9 Hood Installation CAUTION USE HAND TOOLS ONLY DO NOT OVER TIGHTEN SCREWS IT MAY CAUSE DAMAGE TO THE HOOD CAUTION If moving the cooking range is necessary to install the hood turn off the power in an electric range at the main electrical box SHUT OFF...

Page 13: ...the position of the Duct Cover Mounting Bracket F Use reference E from Table 2 and measurements on page 14 15 Attach and secure Duct Cover Mounting Bracket F with two screws not provided Refer to Figure 12 NOTE Inner duct cover will cover the Duct Cover Mounting Bracket 6 Remove the Baffle Filters Position the entire duct cover up onto the hood and secure with six 3 16 x 3 8 screws H from inside t...

Page 14: ...2SQB WM 1 Note For best results turn fan on prior to any preparation or cooking and keep fans running while cooking Adjust speed as needed To operate the fan function Press button to choose from speed o Q QuietMode speed o L Low speed o H High speed Press OFF to turn fan off To operate the light function Press the Light Control to turn lights on and off ...

Page 15: ...born spots Use dry soft towel to dry the hood 3 DO NOT allow deposits to accumulate or remain on the hood 4 DO NOT use ordinary steel wool or steel brushes Small bits of steel may adhere to the surface and cause rusting 5 DO NOT allow salt solutions disinfectants bleaches or cleaning compounds to remain in contact with stainless steel for extended periods Many of these compounds contain chemicals ...

Page 16: ...AX2130SQB 1 and RAX2130SQB WM 1 29 3 4 x 20 x 12 3 16 RAX2136SQB 1 and RAX2136SQB WM 1 35 3 4 x 20 x 12 3 16 RAX2142SQB 1 and RAX2142SQB WM 1 41 3 4 x 20 x 12 3 16 OPTIONAL ACCESSORIES W x D x H 1 30 Stainless Steel Back Panel SSP30 30 x 1 10 x 32 2 36 Stainless Steel Back Panel SSP36 36 x 1 10 x 32 WEIGHT lbs Net Gross RAX2130SQB 1 30 33 0 42 0 RAX2136SQB 1 36 RAX2142SQB 1 42 35 5 37 5 44 0 48 5 ...

Page 17: ...onverted from millimeters Inch measurements are estimated All measurements in are millimeters FOR UNDER THE CABINET MODEL NO RAX2130SQB 1 30 RAX2136SQB 1 36 RAX2142SQB 1 42 FOR WALL MOUNT MODEL NO RAX2130SQB WM 1 30 RAX2136SQB WM 1 36 RAX2142SQB WM 1 42 ...

Page 18: ...15 Hood Mounting Bracket Duct Cover Mounting Bracket ...

Page 19: ...3 Hood Casing RAX2130SQB WM 1 10 2130B RAX2136SQB WM 1 10 2136B RAX2142SQB WM 1 10 2142B 4 Capacitor L1 0401 0120 24 5 LED Light Driver L1 04012 D001 6 LED Light Support RAX2130SQB WM 1 B101 2130B 06 RAX2136SQB WM 1 B101 2136B 06 RAX2142SQB WM 1 B101 2142B 06 7 LED Light 3W L1 0403 0301 8 Control Unit L1 0405 0301 9 Blower system 2P L1 0302 0120 802RO 10 Baffle Filter L1 0214 0122 ...

Page 20: ...17 ...

Page 21: ... Mounting Bracket L1 0201 03900 5 Hood Casing RAX2130SQB WM 1 10 2130B RAX2136SQB WM 1 10 2136B RAX2142SQB WM 1 10 2142B 6 Capacitor L1 0401 0120 24 7 LED Light Driver L1 04012 D001 8 LED Light Support RAX2130SQB WM 1 B101 2130B 06 RAX2136SQB WM 1 B101 2136B 06 RAX2142SQB WM 1 B101 2142B 06 9 LED Light 3W L1 0403 0301 10 Control Unit L1 0405 0301 11 Blower system 2P L1 0302 0120 802RO 12 Baffle Fi...

Page 22: ...19 ...

Page 23: ...20 CIRCUIT DIAGRAM MODEL NO RAX2130SQB 1 30 RAX2136SQB 1 36 RAX2142SQB 1 42 RAX2130SQB WM 1 30 RAX2136SQB WM 1 36 RAX2142SQB WM 1 42 ...

Page 24: ...ctive Replace LED light fixture s The light wiring s is loose Check wire continuity from Control Panel to LED Driver to LED light fixture s The control panel or LED light driver is defective Replace the control panel or LED light driver The range hood is not venting out correctly The range hood is installed outside of the manufacture recommended clearance Adjust the clearance between the range hoo...

Page 25: ...s shipping expenses Un installation of defective product and Installation of replacement product Warranty Exclusions This warranty does not cover including but not limited to the following a Improper installation b Any repair alteration modification not authorized by KOBE c Duct alteration modification and connection d Incorrect electric current voltage or wiring e Normal maintenance and service r...

Page 26: ...number 5 Have a description of the nature of any defect in the product or part TO REQUEST WARRANTY SERVICE PLEASE CONTACT THE KOBE RANGE HOODS SERVICE CENTER KOBE SERVICE CENTER USA ONLY Toll Free 1 855 800 KOBE 5623 E mail kobe adcoservice com For service in Canada and to report a problem please contact Phone 1 626 775 8880 Email customer service koberangehoods com ...

Page 27: ... purpose 1 Date of purchase 2 Model No 3 Serial No For warranty service or spare parts purchase contact KOBE Service Center USA ONLY Toll Free 1 855 800 KOBE 5623 Email kobe adcoservice com For service in Canada and to report a problem please contact Phone 1 626 775 8880 Email customer service koberangehoods com Your notes ...

Page 28: ... d utiliser cette hotte à l étranger puisque l alimentation électrique pourrait ne pas être compatible et enfreindre le code de l électricité de ce pays L usage de la hotte KOBE à l étranger est à votre propre risque et la garantie sera annulée Esta campana de extracción KOBE ha sido fabricada para ser utilizada únicamente en EE UU y CANADÁ No recomendamos la utilización de esta campana en el extr...