IRTLC750I 

 

 

 

 

Dual Thermometer – 

Infrared and folding probe 

 

Product Code: IRTLC750I 

 

 

 

t/

 +44 (0)1473 461 800 

e/ 

[email protected] 

       

 

www.klipspringer.com 

   

Klipspringer Ltd  

Rynor House, Farthing Road, IPSWICH, UK, IP1 5AP

 

Summary of Contents for IRTLC750I

Page 1: ...TLC750I Dual Thermometer Infrared and folding probe Product Code IRTLC750I t 44 0 1473 461 800 e service klipspringer com www klipspringer com Klipspringer Ltd Rynor House Farthing Road IPSWICH UK IP1 5AP ...

Page 2: ...2 This page is intentionally left blank ...

Page 3: ...ABLE OF CONTENTS 1 INTRODUCTION 4 2 CAUTION 4 3 OPERATION 5 4 TEMPERATURE MEASUREMENT 6 5 MALFUNCTION INDICATORS 6 6 BATTERIES 6 7 TECHNICAL DATA 7 8 SERVICE 7 9 CLEANING 7 10 CALIBRATION 8 11 ASSURANCE 8 ...

Page 4: ...rature changes always allow device to stabilize for 30 minutes before use 2 4 Risk of injury When the probe needle is folded out there is a risk of injury Risk of contamination When injured by the probe needle you could be infected with dangerous bacteria You may burn yourself After measuring objects at high temperatures the feeler needle may stay hot for some time Avoid twisting the plunge feeler...

Page 5: ...d sensor point the infrared lens at the point you would like to measure and press the button 1 The core temperature probe must be closed Point the sensor in such a way that both laser points are visible on the object you are measuring The area between the two laser points represents the surface whose temperature will be measured 3 3 MIN and MAX display During the measurement the highest and lowest...

Page 6: ...1 HI display temperature measured is above range HI display an open circuit is detected in probe or cable LO display temperature measured in below range LO display a short circuit is detected in probe or cable Three dashes display probe disconnected or broken 5 2 Contact our technical helpline if diagnosis is not clear 6 0 BATTERIES 6 1 The lithium battery has an expected lifespan of up to five ye...

Page 7: ...s 169 5 x 44 x 23 mm without probe Weight 140g approximately 8 0 SERVICE 8 1 For service and repairs please send the unit to the address below in the box provided for your use DO NOT attempt to open the case The instrument contains delicate electronic components and opening the case may invalidate your warranty Address Service Centre Klipspringer Ltd Rynor House Farthing Road IPSWICH IP1 5AP UK 9 ...

Page 8: ...0 3 The thermometer will be returned within one week of receipt accompanied by a certificate of calibration 10 4 Klipspringer is a UKAS accredited laboratory for temperature calibration 0764 in accordance with International Standard ISO IEC 17025 This service is provided to cover almost any brand of hand held probe thermometer 10 5 Klipspringer will automatically notify you of the due date for cal...

Page 9: ...9 Copyright 2021 Klipspringer Ltd ...