manualshive.com logo in svg
background image

 57"

(144.8 cm)

27"

(68.6 cm)

33"*

(83.8 cm)

42"**

(106.7 cm)

PRODUCT MODEL NUMBERS

OVERALL DIMENSIONS

EXHAUST VENTING

KHEV01R

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only.  For complete details, see Installation
Instructions packed with product.  Specifications subject to change without notice.

Ref. 3957654

06-27-06

RECESSED AREA AND CLOSET INSTALLATION WITH OR WITHOUT PEDESTAL

UNDERCOUNTER INSTALLATION

A. Front view
B. Side view

C. Cabinet with vents

7"* (17.8 cm)

7"* (17.8 cm)

 (12.7 cm)

33"

(83.8 cm)

  1"
(2.5 cm)

5"

27"

(68.6 cm)

1"

 (2.5 cm)

(2.5 cm)

1"

A

B

C

For closet installation, with a door, the minimum ventilation openings in the top and
bottom of the door are required. Louvered doors with equivalent air ventilation openings
in the top and bottom are acceptable.

    1"
(2.5 cm)

    1"
(2.5 cm)

  42" min.
(106.7 cm)

     27"
(68.6 cm)

1"
(2.5 cm)

Vent system chart 1 - rigid metal vent only

Vent system chart 2 - rigid metal vent used with a 
maximum of 8 ft (2.4 m) flexible metal vent

Number of 
90º turns 
or elbows

Type of
vent

Box or 
louvered 
hoods

Angled
hoods

0

Rigid metal

174 ft (53.0 m)

168 ft (51.2 m)

1

Rigid metal

164 ft (50.0 m)

158 ft (48.0 m)

2

Rigid metal

154 ft (46.9 m)

148 ft (45.1 m)

3

Rigid metal

145 ft (44.2 m)

139 ft (42.4 m)

4

Rigid metal

137 ft (41.8 m)

131 ft (39.9 m)

Number of 
90º turns 
or elbows

Type of
vent

Box or 
louvered 
hoods

Angled
hoods

0

Rigid metal

144 ft (43.9 m)

138 ft (42.1 m)

1

Rigid metal

134 ft (40.8 m)

128 ft (39.0 m)

2

Rigid metal

125 ft (38.1 m)

119 ft (36.3 m)

3

Rigid metal

117 ft (35.7 m)

111 ft (33.8 m)

A. Louvered hood style

B. Box hood style

      4"
(10.2 cm)

      4"
(10.2 cm)

A

B

  4"

(10.2 cm)

2.5"

(6.4 cm)

Dimensions shown are for minimum spacing.

Recommended hood style

Angled hood style is

acceptable.

• Select the route that will provide the straightest and most direct path outdoors.  

• Plan the installation to use the fewest number of elbows and turns. Use the fewest

90° turns possible.  

• Do not use vent runs longer than specified in vent length chart.

• Determine the number of elbows you will need.

Electrical:

To supply the required 3 or 4 wire,

single phase, 120/240 volt 60 Hz, AC only electrical
supply (or 3 or 4 wire, 120/208 volt electrical
supply, if specified on the serial/rating plate) on a
separate 30-amp circuit, fused on both sides of the
line. A time-delay fuse or circuit breaker is
recommended. Connect to an individual branch
circuit. Do not have a fuse in the neutral or
grounding circuit.

Exhaust venting:

Exhaust your dryer to the

outside. Four inch diameter vent is required. Rigid
or flexible metal exhaust vent must be used. Do not
use plastic or metal foil vent. Exhaust outlet hood
must be at least 12 inches from the ground or any
object that may be in the path of the exhaust.

Recommended installation
spacing for cabinet installation

For cabinet installation, with a door,
the minimum ventilation openings in
the top are required.

*Includes door handle

**Includes feet extended 1" (2.5 cm)

NOTE:

Most installations require a minimum 

5" (12.7 cm) clearance behind the dryer for
the exhaust vent with elbow. See Installations
Instructions, “Venting Requirements.”

Pro Line

®

Front-Loading Electric Dryer

®

*Required spacing

A. Front view
B. Side view - closet or confined area

C. Closet door with vents

A

B

     1"
(2.5 cm)

 1"

(2.5 cm)

  27"

(68.6 cm)

5"

(12.7 cm)

      1"

(2.5 cm)

 33"

(83.8 cm)

 3"*

(7.6 cm)

3"*

(7.6 cm)

48 in.

2

*

(310 cm

2

)

24 in.

2

*

(155 cm

2

)

C

Отзывы: