background image

smart slider
LD350 / LD700

07/2022

997-00210-EN

Field assembly &
commissioning

Summary of Contents for LD350

Page 1: ...smart slider LD350 LD700 07 2022 997 00210 EN Field assembly commissioning ...

Page 2: ...YOUR PROJECT DATA ...

Page 3: ...p procedure Additional instructions for double or multi leafs Operating mode explanation Menu modus Menu Access to system Menu Parameters Menu Logics Menu Auto program Menu Multi leafs Menu Data Menu Password Menu Reset default Menu Only Expert Menu Exit Legal notice Contents Index Title page 3 Keller minimal windows 997 00210 07 2022 Keller minimal windows 04 05 06 07 09 10 11 13 14 19 20 21 22 2...

Page 4: ...ply 1x 100 240 V AC 50 60 Hz 10 A fused Current in max 4 A LD350 LD700 Power consumption max 350 W max 2x 350 W Standby power consumption 2 1 68 W 3 36 W Leaf overall weight 3 max 1 500 kg max 2 400 kg Movement path max 10 000 mm max 12 000 mm Force on timing belt 4 max 350 N max 700 N Motor Dunker 400 Ncm 2x Dunker 400 Ncm 1 dependant on the door weight and opening width 2 excl add components saf...

Page 5: ...eaf 4 leaf width leaf mm width leaf mm width leaf mm width leaf mm total weight total weight total weight total weight Note In the red zone are a number of factors that play a role in determining possible weight Standard or freeway floor Orientation north east south west Direct or partial solar radiation Or constant shadow roof overhang Color of the window light or dark color Examples of the best ...

Page 6: ...f danger Risk of physical pinching Symbol of attention Read the note very carefully if this symbol is mentioned Procedure FIRST THINGS FIRST Mount the drive beam correctly according to the assembly instructions see page 10 33 Couple the window with the flight bar Insert the powerplug then an LED will light up under the LCD display of the control PCB Now we are ready to complete the basic settings ...

Page 7: ...connectors only for manufacturer E1 reset button E3 program D1 adjustement contrast LCD E2 operation scroll E4 operation scroll ground limit switch limit switch ground 7 6 Volt signal lock limit switch lock common 0V power in 24 36V power in 5V A B 0V mot mot A1 limitswitch A2 lock A3 power encoder motor gnd 7 6V signal lswl com 0V 24 36V 5V A B 0V mot mot gnd lsw lsw 7 Keller minimal windows 997 ...

Page 8: ...omm safety Close n c Test signal output signal n o door closed output signal n o door closed output signal n o door opened output signal n o door opened input comm pedestrian opening n o input command pedestrian function C1 command C2 safety open C3 safety close C4 options com stop close open 0V 24V com s open tst 0V 24V COM S Close Tst CL Common OP Common Ped Common ground rx tx ground B1 master ...

Page 9: ...k Limit switch left is activated also limit switch slow speed Limit switch right is ok It s mode is Automatic with automatic closure active a single use motorisation a Left opening system configuration and a Close command is given commando s O Open C Close S Stop p Pedestrian opening master slave single use M Master S Slave Y Master synchro operation modus a Auto mode A Auto mode auto close active...

Page 10: ...v s sliding direction sliding direction sliding direction This means that the motor is always mounted above the sliding leaf closed position In a multi part sliding leaf the motor is mounted above the first sliding leaf L direction sliding leaf to LEFT r linear drive position on RIGHT R direction sliding leaf to RIGHT l linear drive position on LEFT 10 Keller minimal windows 997 00210 07 2022 Kell...

Page 11: ...nsions 7 1 LD350 Linear drive housing dimensions 7 2 LD350 Opening width of the drive way Without linear drive a 60 mm b 20 mm c 75 mm Measures with equal glass dimensions A 1200 mm B available course C 100 mm With LD350 a 130 mm b 90 mm c 145 mm 11 Keller minimal windows 997 00210 07 2022 Keller minimal windows ...

Page 12: ...sions 7 1 LD700 Linear drive housing dimensions 7 2 LD700 Opening width of the drive way Without linear drive a 60 mm b 20 mm c 75 mm Measures with equal glass dimensions A 1200 mm B Available course C 350 mm With LD700 a 310 mm b 270 mm c 325 mm 12 Keller minimal windows 997 00210 07 2022 Keller minimal windows ...

Page 13: ...nning document These zone must be sufficiently protected against any risk of crushing both on the inside and the outside The use of self testing sensors is mandatory EN16005 A connection point is provided for opening and closing security accessories Upon detection the drive will stop immediately and slide in the other direction for approx 20 cm 13 Keller minimal windows 997 00210 07 2022 Keller mi...

Page 14: ...ail Make sure it is secured with the barb This will keep the drive in place Then secure this with the supplied bolts M5x08 DIN6921 After installation check again that all bolts are firmly tightened In addition the u housing can be fixed to the building structure by means of a corner profile and the necessary fasteners These parts are not provided nor included The drive is already configured accord...

Page 15: ...behalten wir uns alle Rechte vor auch für den Fall der Patenterteilung Gebrauchs oder Geschmacksmustereintragung Ohne unsere schriftliche Zustimmung darf weder die Zeichnung selbst noch Vervielfältigung hiervon oder sonstige Wiedergaben des vollständigen oder auszugsweisen Inhalts Dritten zugänglich gemacht oder in anderer Weise missbräuchlich verwendet werden This drawing is protected by copyrigh...

Page 16: ...th mounting aid n3mm e g allen key sichern mit Montagehilfe n 3mm z B Inbusschlüssel screw both parts together unsecure beide Teile miteinander verschrauben entsichern ZK2 26 05 402 13 n6 n10 n5 n12 18 16 2 axis of junction Achse Verhakung milling of junction profiles Bearbeitung Verhakungsprofile A A 1 3 B B 1 3 A A B B Für diese Zeichnung behalten wir uns alle Rechte vor auch für den Fall der Pa...

Page 17: ...nssen W Schulzen Reference Title Drawing No Scale 1 3 1 5 flight bar milling smart slider LD ZK 65x34mm Keller minimal windows 4 Material Refer to protection notice ISO 16016 Schutzvermerk ISO 16016 beachten 29 11 2021 2 5 7 6 1 4 3 30 30 30 45 n6 13 n10 20 65 n5 n12 16 2 18 smart slider LD ZK 65x34mm flight bar milling smart slider LD ZK 65x34mm Mitnehmer Bearbeitung milling of junction profiles ...

Page 18: ...rresponding dot indicator switches on and off 9 2 2 DOOR OPEN POSITION Limit switch detector on the UPPER timing belt 1 Open the door to the maximum desired end position 2 Unscrew slightly the premounted limit switch detector and move it until the limit switch actuates click 3 Re tighten the detector again on this position 9 2 3 DOOR CLOSED POSITION Limit switch detector on the LOWER timing belt 1...

Page 19: ... procedure 4 Test both windows for proper functioning 5 Switch off the power to the system 6 Place wiring between master and slave operators master rx to slave tx master tx to slave rx gnd with gnd MASTER SLAVE 7 Switch on the power 8 Put first slave in Slave modus see 14 3 Logics Configurations at page 26 9 Put master in Master modus see 14 3 Logics Configurations at page 26 10 Whenever you chang...

Page 20: ...t 5 seconds After entering the default password 9 you can scroll with the arrow keys to the AUTO Prog menu see pages 25 26 Make sure that nothing or nobody is in the area where the window is moving Press the E3 key to start the procedure and confirm again wherever the window is located a closing procedure will be performed first at slow speed The system will initialize to its zero point fully clos...

Page 21: ... on page 19 in the Multi Windows menu Example double combination 2 times sliding fix Example quadruple combination 4 times sliding fix Example penta combination 5 times sliding fix 1st leaf in cm s 1st leaf in cm s 1st leaf in cm s 1st leaf in cm s 2nd leaf in cm s 2nd leaf in cm s 2nd leaf in cm s 3th leaf in cm s 3th leaf in cm s 4th leaf in cm s SR SR SR SR SR SR DW DW DW DW SR SR SR SR SR Soft...

Page 22: ...esired direction according to the given command At any time the movement can be stopped by a pulse command in the opposite direction the door will stop immediately the next command will move the leaf again This mode absolutely requires the necessary safety accessories to prevent the risk of crushing With one pulse the sliding window can be opened or closed following next sequence OPEN STOP CLOSE O...

Page 23: ...t Elect Antiburglar On Off AUTO PROG page 27 28 Learning mode obstacle detection MULTI WINDOWS telescopic systems page 29 Soft Run distance 5 40 cm 10 Delta Window dimension 0 40 cm 10 Distance to 1st contact window 0 900 cm 0 Distance to 2nd contact window 0 900 cm 0 Distance to 3th contact window 0 900 cm 0 Distance to 4th contact window 0 900 cm 0 DATA page 30 Open Cycles info info Close Cycles...

Page 24: ...Power during closing Power during opening Power during closing Speed during opening Speed during closing Speed during opening Speed during closing Worktime needed time 5 sec At normal speed 0 99 30 At normal speed 0 99 30 at slowing down period 0 99 50 at slowing down period 0 99 50 at normal speed 10 20 cm sec 12 at normal speed 10 20 cm sec 12 at slowing down period 4 12 cm sec 8 at slowing down...

Page 25: ...ant to be done L R LEFT before any operation very important to be done L R RIGHT before any operation at normal kickstart 0 99 10 0 not activated 0 900 cm 0 extra push when window is fully closed 0 99 ms 50 for smooth runout inertia 10 99 cm 30 at normal soft run back to menu Parameter explanation LCD screen NOTE Always be aware about safety directives EN 16005 This parameter should be programmed ...

Page 26: ... Smart Slider Plus Top Slider Top Slider Plus Top Slider Plus Info has to be put on the exact system see label for more info Single Master Slave M sync Stand Standard Magnet Optional magnetical lock Elect Optional electrical lock Antiburglar function whenever window is fully closed ON or OFF ON Conformity of the KMW models Smart slider NOT IN USE Smart Slider Plus LD350 Smart Slider Plus LD700 Top...

Page 27: ...LOSE position detected OPEN position detected E2 E4 abort NOTE Always ensure that this action is performed under safe conditions by a specialized technician During this operation there is no obstacle detection as automatic motor actions take place Mark the area in which the window is moving and make sure that no obstacles and or people are in the area during the gradient Once started the process i...

Page 28: ...ield assembly commissioning smart slider Field assembly commissioning 14 Menu modus 14 4 MENU AUTO PROGRAM All data will be saved power graph Last closing opening Saving information Programming OK Parameter explanation LCD screen Additional information 28 Keller minimal windows 997 00210 07 2022 Keller minimal windows ...

Page 29: ...stance till end of second leaf Distance till end of third leaf Distance till end of fourth leaf Exit multi window menu Soft run period 0 40 cm 10 Before and after detection Thickness leaf frame 0 40 cm 10 distance in cm 0 900 cm 0 double leaf 0 not active distance in cm 0 900 cm 0 triple leaf 0 not active distance in cm 0 900 cm 0 quadruple leaf 0 not active distance in cm 0 900 cm 0 penta leaf 0 ...

Page 30: ...hange password Confirm with P E3 button Number of CLOSE cycles Exit DATA menu to continue 0 999 9 Note OPEN direction extra slowdown zones will not be reset to continue push P E3 button back to main menu Parameter explanation Parameter explanation Parameter explanation LCD screen LCD screen LCD screen factory Additional information Min Max settings factory Additional information Min Max settings f...

Page 31: ...IT Menu modus Meaning the locking is active The crocodile lock is closed or in down lower position This is for controlling the crocodile locking positions Meaning the locking is inactive The crocodile lock is open or in upper position For choosing a bluetooth number to connect with your smart device like smartphone or tablet The number 99 means that bluetooth is not active Parameter explanation Pa...

Page 32: ...NOTES ...

Page 33: ...NOTES ...

Page 34: ...NOTES ...

Page 35: ...es The reproduction of common names trade names product descriptions etc in this work does not justify the assumption that such names are to be considered free in the sense of trademark and brand protection legislation and may therefore be used by anyone even without special labelling The contents and data contained in this work are protected by copyright All rights to the contents are the sole pr...

Page 36: ...07 2022 KELLER Minimal Windows S A 38 40 Route de Wilwerdange L 9911 Troisvierges www minimal windows com ...

Reviews: