Summary of Contents for WP-CONTROLS

Page 1: ...PDF provided by Conference Room AV KanexPro WP CONTROLS Wall Plate Control Panel for IR RS 232 RS 485 Silver...

Page 2: ...Programmable Control Panel Wall Plate All Rights Reserved Version Programmable Control Panel 2013V1 2...

Page 3: ...This manual is for operation instruction only not for any maintenance usage The functions described in this version are updated till May 2013 Any changes of functions and parameters since then will b...

Page 4: ...4 1 Interfaces Introduction 2 4 2 Connection of Programming and Looping 3 5 System Operations 5 5 1 Front Panel Introduction 5 5 2 USB Driver Installation 5 5 3 Software Programming 5 5 3 1 Main Menu...

Page 5: ...ts 1 x Programmable Control Panel 1 x Power adapter DC 12V 4 x Captive screw connector 3 x IR emit probe 1 x Button labels 1 x User Manual Note Please confirm if the product and the accessories are al...

Page 6: ...ply 100VAC 240VAC 50 60 Hz Power Consumption 1W Case Dimensions 114x70 x28mm Product Weight 0 15kg 4 Connection Introduction 4 1 Interfaces Introduction The programmable control panel has various port...

Page 7: ...5 is the same as RS232 1 Low Voltage relay ports set the relay on off by software PS WP Power connector 12VDC Be sure that the and never be mixed or wrong connection Infrared sensor port receive and l...

Page 8: ...After connect the programmable control panels as above and then we should set the ID of each programmable control panel by PS WP The ID number is from 01 to 99 and it also is the class of the programm...

Page 9: ...ecific transparent paper table please contact the local distributor or reseller for it 5 2 USB Driver Installation There are USB driver file and PS WP software in the disk The PS WP can run directly w...

Page 10: ...f all functions The main window of PS WP is as below We will introduce all the configurations one by one 5 3 1 Main Menu The main menu includes file management system model connection type and help 1...

Page 11: ...e two shared ports The dialog is as the picture below The output port set in PS WP and the port used in the programmable control panel is corresponding And there are four output types They are showed...

Page 12: ...action list then add events to this action make this action will execute the events Here take WP8 V for example to introduce the uses of different buttons 1 White keys keys 1 8 correspond to the butt...

Page 13: ...tual keys used in the loop function When use the loop function the ID must be set the ID can be 1 to 99 Press add will add the button to action list Key Action Type 1 Press Execute events when press b...

Page 14: ...e is counted from the programmable control panel start When come to time1 the programmable control panel will execute the events in time1 Then recount from time2 and then time3 Example Set time1 to 5...

Page 15: ...setting the parameters of the programmable control panel s serial ports Click RS232 it will show as below 1 The data of RS232 can be directly entered or selected from library Click Change Lib to sele...

Page 16: ...tween times can be set See in picture below 3 The send port must be selected as the same as model setting otherwise the event cannot be added 4 User can set the event name It is optional function not...

Page 17: ...then press OK 2 There are two send types send once and send more times When select more times the send times and the delay between times can be set See in picture below Select a function and then cli...

Page 18: ...e programmable control panel so the setting is not introduced in this manual Relay Setting This item is for the replay ports setting The setting is as the picture below Delay setting This item is to s...

Page 19: ...ting is as the picture below 1 The send port must be selected as the same as model setting otherwise the event cannot be added And port 1 cannot be used for compare for there is no a receive pin in th...

Page 20: ...e set to type page that include four actions To change different actions it will need other white buttons to active the page action number Here take a example to show you the use of this function 1 Ta...

Page 21: ...the button5 and then button1 the button1 will execute the event of num1 press button1 more times it will execute num1 more times b When press the button6 and then button1 the button1 will execute the...

Page 22: ...he toggle setting is as the picture below The setting steps of toggle are similar with the page setting But toggle performs differently for the actions in it are loop running it will perform as below...

Page 23: ...cute num4 then num1 num2 num3 and so on d When press the button8 and then button1 the button1 will execute the event of num4 press button1 more times it will execute num1 then num2 num3 num4 and so on...

Page 24: ...to the dealer for repairing 2 When USB cannot open or without response please make sure the USB driver is installed correctly and then reconnect the USB cable 3 When uploading the USB cannot be found...

Page 25: ...in case of accident or increasing the damage of the equipment 7 DO NOT splash any chemistry substance or liquid in the equipment or around 9 After sales Service 1 If there appear some problems when r...

Page 26: ...will be warranted for the remainder of the original warranty period of 3 years whichever is longer C NO OTHER WARRANTIES TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW KANEX DISCLAIMS ALL OTHER WAR...

Page 27: ...Programmable Control Panel 23 Brea California KanexPro com MPN WP CONTROLS KanexPro is a trademark of Apogee Inc registered trademarks in the U S...

Page 28: ...Programmable Control Panel 24...