background image

The PURO GRAND Condensate Cleaner 

Installation instructions: 

 
The PURO  GRAND condensate cleaner has been specially developed to separate oil from condensate extracted from compressed air systems and  is 
effective with all types and makes of compressors, oils and drain valves. 
 
To obtain the best performance from the machines, we suggest the following: 

 

Installation instructions: 

 

1) 

The unit is designed to easily fit against a wall. Position the machine with the TEST to the front and remove the lids from the top of both 
vessels. 

2) 

After ensuring that no harmful pressure exists, connect the condensate inlet pipe(s) using the 1/2"

"

 inlet connections. If only one connection is 

used, the others can be sealed with a screwed plug.  Do not over-tighten connections. 

3) 

Connect the 1/2" outlet connection  to a suitable sewage drain. Do not over-tighten connections. 

4) 

Lift the poly-element from vessel (1) and place it to one side for the time being. 

5) 

Remove the plastic packing material from the activated carbon element and slide it back in to the vessel (2) and let it rest on  the bottom of  the 
vessel. Place the closed lid on vessel (2). 

6) 

Remove the depressuriser foam pad, pour clean water into the depressuriser box until it flows from the outlet pipe and then replace the foam 
pad into the depressurising box. 

7) 

With the cable-tied end upwards, replace the white poly-element into vessel (1) by slowly pushing the element down into vessel 1  

 

(the poly-element  should rest on  the bottom of  vessel 1). 

8) 

Place lid 1 on vessel 1. 

9) 

Your condensate cleaner is now ready for use. 

 

 
Note: During initial filling, dust may rise from the carbon elements; this is only displaced air and is entirely harmless. We recommend the active 
carbon element to be pre-soaked for 24 hrs. Any carbon dust in the outlet water is harmless. 
 
We recommend that initially a daily check is made on the quality of the output from your condensate cleaner. After a day or so, the output should be 
clear when viewed in a clear glass container. 
 
We recommend that you use our protection clothing kit when installing and or servicing the condensate cleaner. 

 

Maintenance instructions: 

 
 

Used elements can be heavy and we strongly advise that normal precautions for the lifting of heavy weights are taken. 

 

To replace the poly-element, remove  the  lid  from the top of  the  vessel  (1) and  lift the  used poly-element out of  the  vessel. Simply lower the new  
poly-element slowly into the vessel (1) and let it rest on the bottom of vessel 1. 
 
To change carbon elements, remove a carbon element  from  its  vessel (2) after  removing  the  lid,  lift  the  used carbon element  from the  vessel and 
place where the draining water will cause no harm. Slide the new carbon element into the vessel (2) until it rests on the bottom of the vessel. The top 
of the carbon element should be below the outlet hole. If required, clean water can be poured onto the top of the carbon element to prevent dust. 

 
All  used elements must  be properly  disposed of in accordance  with curre nt  regulations for the dis posal of hazardous  waste in your area. 

 

 

Reviews: