background image

Fume Extractor

Ref. FAE2-5B

INSTRUCTION MANUAL

www.jbctools.com

Summary of Contents for FAE2-5B

Page 1: ...Fume Extractor Ref FAE2 5B INSTRUCTION MANUAL www jbctools com ...

Page 2: ...unit Ref 0004009 Manual 1 unit Ref 0023482 Power cable 1 unit Ref 0009417 100V 120V 0009401 230V RJ12 direct cable 2 units Ref 0019751 Important Before using unseal the filter and remove the bottom protection of the compact filter RJ12 USB A adapter 2 units Ref 0023504 USB A B cable 2 units Ref 0021042 INSTRUCTION MANUAL 2 Fume Extractor Ref FAE2 5B www jbctools com ...

Page 3: ...benchs Wheels and brake system to move around easily Filter saturation indicator Green Filter OK Yellow 20 carbon lifetime or about to saturate Red End of carbon lifetime or filter saturated Quick release lever for filter change Power socket Main switch Process screen Pedal connections RJ12 station connections USB B connections www jbctools com 3 ...

Page 4: ...ons onwards Ref FAE060 For compact stations From B versions onwards Flexible arms Ø50 Ref FAE070 Lenght 1 m 39 37 in To be assembled on your workbench with the included clamp Ref FAE020 To be assembled directly on your workbench hole drilling required Flexible Hoses Ø50 Ref FAE010 Lenght 1 5 m 59 05 in Connect the Fume Extractor to the flexible arm or to the accessory for stand aspiration 2 work i...

Page 5: ... flow is set High Note that in this configuration suction force per intake is decreased when compared to 2 work intakes configuration see details on page 14 Change Work intakes parameter into 4 in order to set this configuration see page 7 For a basic working system you need Flexible arms Ø50 Ref FAE070 Lenght 1 m 39 37 in To be assembled on your workbench with the included clamp Ref FAE020 To be ...

Page 6: ...on the display shows a similar screen as the following one and the filter saturation indicator is green if the carbon lifetime is higher than 20 If the display shows STOP 4 or STOP 7 power off the fume extractor remove the cover place it back and secure it using the quick release levers Menu Interface Main screen Main screen may vary according to the Work intakes and Program parameters For 2 work ...

Page 7: ... 4 Pedal port 1 1 Delay port 1 2 Delay port 2 3 Delay port 3 4 Delay port 4 Port 5 Pedal ports 1 and 2 6 Pedal ports 3 and 4 Back Total Counters 1 Plugged hrs 100 2 Idle hrs 10 3 Work area hrs 70 Port 1 2 OK 4 Stand hrs 20 5 Work area cys 10 Port 1 2 OK Back 4 Stand hrs 20 5 Work area hrs 10 6 Reset Port 1 2 OK Back Partial Counters 1 Plugged hrs 100 2 Idle hrs 10 3 Work area hrs 70 Port 1 2 OK Me...

Page 8: ...lay port 2 4 Pedal port 1 Back 5 Pedal port 2 Delay to stop port 1 1 Work area 5 sec 2 Stand 30 sec Back Pedal port 1 1 Activation One touch 2 Mode Pressed Back Port 1 Program Ctm 100 2 Delay pt 1 3 Delay port 2 4 Pedal port 1 Custom Custom program Select work area flow 80 Delay to stop port 1 1 Work area 5 sec Back Menu Interface 1 Port menu 2 work intakes configuration OK 2 Port menu 4 work inta...

Page 9: ...ation remains active until continuous mode is disabled or the equipment is powered off By default Continuous mode is OFF Beep Enable disable the sound of the keypad By default Beep is ON PIN Enable disable PIN request when modifying parameters By default PIN is ON Change PIN Change the default security PIN code By default the PIN is 0105 Work intakes It sets how many intakes will work as workbench...

Page 10: ...aspirating fumes on the work area once the tool is returned to the stand range 0 300 seconds By default Work area time is 5 seconds Delay to stop Stand It sets the time that a fume extractor keeps aspirating fumes at the stand once the tool is returned to it range 0 999 seconds By default Stand time is 60 seconds Pedal Activation It sets the pedal activation mode One touch Press the pedal once to ...

Page 11: ...0 is reached the system will show pop up message STOP 2 to replace the filter Reset carbon Perform this action after replacing the HEPA carbon filter set The car bon lifetime counter will not start until the filter is detected for the first time After executing that function Carbon life will be 100 Extraction control Fume extractor aspiration may be controlled by Pedal connection By means of the P...

Page 12: ...tor FAE_a Back Connect up to 4 stations directly to a fume extractor through the Soldering Station Robot port Every tool connected to a station can control the aspiration system but previously it has to be assigned to the fume extractor through the Peripherals menu of the station Each station detects a fume extractor as a FAE_a For a correct operation always update soldering stations with the late...

Page 13: ...ed to RJ12 connector StationX can control WorkX intake e g Station2 controls Work2 RJ12 USB A adapter USB A B USB B connection Allows updating fume extractor Continuous mode When continuous mode is enabled the 4 aspiration intakes are opened and fume extractor suction is activated Aspiration remains active until continuous mode is disabled or the equipment is powered off See details on page 9 Fume...

Page 14: ...following table 2 work intakes 4 work intakes Work aspiration intakes 2 4 Stand aspiration intakes 2 Not available Flow per work intake 76 m3 h 44 73 cfm 52 m3 h 30 6 cfm Flow per stand intake 4 m3 h 2 35 cfm Not available Preset aspiration programs 3 1 Custom aspiration programs 9 Not a available Power consumption 400 W 500 W 14 ...

Page 15: ... compact filter has been replaced the filter counter must be reset Main Menu Filter set Reset carbon If the display shows an error when the equipment is switched on it is probable that the cover and casing connectors image 2 are dirty and making false contact Remove the cover and clean both connectors If the filter is changed while the fume extractor is on once the cover is placed the equipment st...

Page 16: ...e dirt residues Latch Adjustment The locking force between casing and cover can be adjusted by turning the knurled nut of the locking mechanism Turn clockwise to loosen and counterclockwise to tighten Clean the disc and the gasket on both sides Intake valve Ref 0018831 Maintenance Valves Read safety guidelines to do the equipment maintenance safety 16 ...

Page 17: ...dling dirt filter or pre filter The quick release levers of the casing are only for handling the cover not the complete equipment Do not use the equipment without the filters Saturated filters can not be cleaned and reused Avoid blowing the filter or the dirty parts of the equipment if necessary it is advisable to vacuum Avoid losing particles in the filter during handling it Treat the saturated f...

Page 18: ...Notes 18 ...

Page 19: ...Notes www jbctools com 19 ...

Page 20: ...ards ESD protected This product should not be thrown in the garbage In accordance with the European directive 2012 19 EU electronic equipment at the end of its life must be collected and returned to an authorized recycling facility Warranty JBC s 2 year warranty covers this equipment against all manufacturing defects including the replacement of defective parts and labour Warranty does not cover p...