background image

Other languages can be downloaded from:

WWW.JB-SYSTEMS.EU

ENGLISH

Operation Manual

Version: 1.0

CAM-SPOT 50TW

JB LOGO MET
JUISTE SPACING
(enkel voor JBS !!!)

FOTO / TEKENING
TOEVOEGEN

Summary of Contents for CAM-SPOT 50TW

Page 1: ...Other languages can be downloaded from WWW JB SYSTEMS EU ENGLISH Operation Manual Version 1 0 CAM SPOT 50TW ...

Page 2: ......

Page 3: ...d as a table stand Completely silent operation no noisy cooling fans on board PowerCon compatible powerinlet BEFORE USE Before you start using this unit please check if there s no transportation damage Should there be any do not use the device and consult your dealer first Important This device left our factory in perfect condition and well packaged It is absolutely necessary for the user to stric...

Page 4: ...ged It must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Never let the power cord come into contact with other cables This fixture must be earthed in order to comply with safety regulations Don t connect the unit to any dimmer pack Always use an appropriate and certified safety cable when installing the unit In order to prevent electri...

Page 5: ... decrease the selected value 9 ENTER BUTTON used to confirm your actions 10 COLOR TEMP change the color temperature from warm white WW 3000K to cold white CW 6000K 11 USB SOCKET Please note that this USB connector is NOT used for updates or to connect the unit to a PC Instead this USB connector makes it very easy to add wireless DMX to the unit Just add the optional WTR DMX DONGLE from BRITEQ and ...

Page 6: ...ver any ventilation openings as this may result in overheating The operator has to make sure that the safety relating and machine technical installations are approved by an expert before using them for the first time The installations should be inspected every year by a skilled person to be sure that safety is still optimal SETUP MENU HOW TO SETUP With the setup menu you can fully configure the pr...

Page 7: ...the last selected static color will be used to set the value Once you have the desired level press the ENTER button to save it DMX Fail Used to set the desired DMX loss setting Press the MENU button or UP DOWN buttons until the desired function is showing on the display Hold Projector keeps the last valid output before DMX loss Manual Projector goes to manual mode when DMX is lost Black Out Projec...

Page 8: ... setup the master All slaves must be set to SLAVE mode IMPORTANT make sure that no DMX controller is connected this will result in unexpected behavior Electrical installation for two or more units in DMX mode The DMX protocol is a widely used high speed signal to control intelligent light equipment You need to daisy chain your DMX controller and all the connected units Pin layout XLR 3pin Pin1 GND...

Page 9: ... 1 1 1 CW 000 255 2 2 2 WW 000 255 1 Linear CCT 000 255 2 3 3 Dimmer 000 255 4 Strobe 000 255 MAINTENANCE Make sure the area below the installation place is free from unwanted persons during servicing Switch off the unit unplug the mains cable and wait until the unit has been cooled down During inspection the following points should be checked All screws used for installing the device and any of i...

Page 10: ...d the relevant statements and documents have been deposited by the manufacturer Mains Input AC 180 240V 50Hz Power consumption 52 Watt Power connections PowerCon DMX connections 3pin XLR male female Lamp LED 50W COB CW WW CRI 90 Beam Angle 22 IP Rating IP20 Size see drawing Weight 2 7 kg The information might be modified without prior notice You can download the latest version of this user manual ...

Page 11: ......

Page 12: ......

Reviews: