We recommend that installation be made by a licensed electrician.

Disconnect power at main panel prior to installing or servicing this 

time switch or the equipment connected to it.

Connect in accordance with national and local electrical codes.

Supply Connections: Use gauge specified (AWG #8-14 ) suitable for 75

º

(167

º

F). Replace insulator before turning on electricity to unit.

INSTALLATION AND OPERATING INSTRUCTIONS  

TO SET ON AND OFF TIMES:  

Light 

trippers turn ON. Dark trippers turn 

OFF. Place tripper on dial edge as 

shown in figure and set point of each 

tripper to desired operating time. 

Note if selected time is AM or PM. Hold 

tripper against dial edge and firmly 

tighten knurled screw.

208-277VAC/60Hz

MECHANICAL 
WATER HEATER 
TIME SWITCH

INSTALLATION AND OPERATING 

INSTRUCTIONS TO SET DIAL TO TIME:

Turn dial counter-clockwise until correct 

time is indicated by arrow on nameplate.

FOR TEMPORARY MANUAL OVERRIDE:

Press down external lever on the right to turn 

timer ON. Press external lever up to turn timer 

OFF. 

CAUTION: Do not rotate dial for manual override.

TO REMOVE MECHANISM FROM CASE:

Press lever near case latch to release mainplate and swing the 

movement out. To replace, insert mainplate projections in slots 

opposite latch and swing movement in until it latches.

15146

 

24 HOUR TIME SWITCH

SWITCH: 

DPST

CONTACT RATINGS: 

40 AMP 250V 

10,00VA WATTS 250V

TIMING MOTOR: 

208-277VAC 60Hz

POWER CONSUMPTION:  3 WATTS MAX

Typical Wiring Diagram, 
240 VAC Application

GE5362-41K2

15146 

MANUAL VERSION 1

03/25/11

WWW.JASCOPRODUCTS.COM

O

F

F

O

N

TIM

E

ON TIME 

(Light Tripper)

OFF TIME 

(Dark Tripper)

Knurled Screw

Dial Calibrations

OFF GREEN

EXTERNAL

OVERRIDE

SWITCH

ON RED

GREEN=OFF
RED=ON

LOAD