background image

H0561200A

Installation and  
Op er a tion Man u al

 WARNING

FOR YOUR SAFETY - This product must be installed and serviced by a pro fes sion al pool/

spa service technician. The procedures in this manual must be followed ex act ly.   Failure to 

follow warning notices and instructions may result in property damage, serious injury, or 

death.

Installation and Operation Data

JandyColors

TM

Digital Color Blending,
Underwater Pool and Spa Lights

 

Summary of Contents for JandyColors JPL120100

Page 1: ...ed by a professional pool spa service technician The procedures in this manual must be followed exactly Failure to follow warning notices and instructions may result in property damage serious injury...

Page 2: ......

Page 3: ...9 4 2 Replacing the Light Fixture 9 Section 5 Wiring Options for Controlling Jandy Pool Lights or Jandy Spa Lights 11 5 1 Wiring to an AquaLink RS Control System 11 5 2 Wiring to a Time Clock 12 Secti...

Page 4: ...d which could result in death or serious injury to pool or spa users installers or others due to electrical shock and may also cause damage to property Read and follow the specific instructions below...

Page 5: ...AC 30 feet JPL12030 Jandy Pool Light 120 Volt AC 50 feet JPL12050 Jandy Pool Light 120 Volt AC 100 feet JPL120100 Jandy Pool Light 120 Volt AC 150 feet JPL120150 Jandy Spa Light 12 Volt AC 30 feet JSL...

Page 6: ...r spas c c The light fixture and all metal items within five 5 feet of the pool or spa must be properly The light fixture and all metal items within five 5 feet of the pool or spa must be properly ele...

Page 7: ...ound the light allows the light to be serviced after the pool or spa is filled with water 2 Cut the cord at the Junction Box leaving at least six 6 inches of cord to make connections 3 Strip six 6 inc...

Page 8: ...lly grounds the housing securely to the mounting ring and wet niche Failure to use the screw provided could create an electrical hazard which could result in death or serious injury to pool or spa use...

Page 9: ...oltage transformer must be located at least The Junction Box or for 12 volt models the low voltage transformer must be located at least 8 inches above ground or water level at least four 4 inches abov...

Page 10: ...ectrical hazard which could result in death or serious injury to pool or spa users installers or others due to electrical shock 3 Remove Junction Box cover disconnect the light fixture wires and strai...

Page 11: ...nization must be operated at the same time to assure color synchronization otherwise the otherwise the lights will work independently of each other lights will work independently of each other 5 1 Wir...

Page 12: ...iring Diagram GFCI Ground Ground Neutral Black White Green 12V Jandy Light Black White Green 120V 12V Transformer 120 VAC Power Supply 5 2 Wiring to a Time Clock The Jandy Pool and Spa Lights can be w...

Page 13: ...Blue will be the first color set in the change sequence when the light is turned on again 6 2 To Lock On a Specific Color Set Wait until the desired color is ON during the first cycle of color change...

Page 14: ...the mounting ring and wet niche Failure to use the screw provided could create an electrical hazard which could result in death or serious injury to pool or spa users installers or others due to elect...

Page 15: ...ght new bulbs four 4 sets of P N R0399600 for Jandy Pool Light Jandy Pool Light or four 4 sets of or four 4 sets of P N R0400300 for P N R0400300 for Jandy Spa Light Jandy Spa Light Do not touch the b...

Page 16: ...heck to see that the clamp is properly installed around the entire flange It is important to have the screw already started in is properly installed around the entire flange It is important to have th...

Page 17: ...does not recommend installing 12 volt lights with cord lengths greater than 50 feet A significant voltage drop will occur that dramatically reduces the light output and possibly unit failure Wires fro...

Page 18: ...t 3 N A Bulb Holder and Electronics Assembly Pool NO Purchase New Light 4 R0399600 Bulb Kit 75 Watt Halogen MR 16 EYC 2 bulbs in kit 8 bulbs required per light YES 5 R0399700 Dichroic Lens Holder Asse...

Page 19: ...tronics Assembly Spa NO Purchase New Light 4 R0400300 Bulb Kit 25 Watt Halogen G 4 Capsule 12 Volt AC 2 bulbs per kit 8 bulbs required per light YES 5 R0400400 Dichroic Lens Holder Assembly Spa YES 6...

Page 20: ...es outside the published minimum and maximum specifications 7 Use of non factory authorized parts or accessories in conjunction with the product s 8 Chemical contamination of combustion air or imprope...

Reviews: