background image

LKP4.6 

 

 Installation & User Guide 

Summary of Contents for LKP4.6

Page 1: ...LKP4 6 Installation User Guide ...

Page 2: ...ned from the individual source equipments remote controls into the Jamo LRC4 6 learnable remote control Source and button names as well as macros are also programmed in the LRC4 6 remote All data are then cloned into each LKP4 6 keypad In addition to source control functions the LKP4 6 keypad incorporates Clock Alarm and Sleep timer functions and provides an LCD screen that displays time date sour...

Page 3: ...llation Controls Display Programming Cloning Operation Alarm Function Sleep Function Setup Function Configure Function Learn Function Specifications Troubleshooting Limited Warranty 4 5 7 8 9 10 11 12 13 14 15 16 17 18 18 18 19 ...

Page 4: ... TV as they can also interfere with IR remote controls A distance of 15 feet 4 5 meter is safe with most plasma TV s Do not install the LKP4 6 KP4 6 in areas with high humidity or outdoors Do not install the LKP4 6 KP4 6 within line of sight to another LKP4 6 KP4 6 This could make it difficult to control each zone separately with a remote control Do not install the LKP4 6 KP4 6 within line of sigh...

Page 5: ... the system both main zones and sub zones Example of wiring diagram below of two main zones with an LKP4 6 in one of the zones Speakers Speakers Speaker cables Speaker cables KP4 6 KP4 6 LKP4 6 AM4 6 Cat5 Cat5 PS24 or PS4 6 Max 100ft 30m Ribbon cable supplied with LKP4 6 ...

Page 6: ...x A double decora style face plate not in cluded is placed over the front as shown The LKP4 6 is connected to the KP4 6 using the supplied ribbon cable The KP4 6 is connected to the AM4 6 hub via a Cat5 cable as described in the AVD4 6 and KP4 6 installation guides Front view Rear view ...

Page 7: ...7 Installation LKP4 6 rear panel connections 2 1 1 KP4 6 Connector Connects to the KP4 6 with the supplied cable 2 I C P In circuit programming socket Used to upload software during manu facturing ...

Page 8: ...uttons are also programmed in the remote Below is an example on how the buttons could be programmed and named for a DVD player max 8 characters for names Note The functions of buttons 1 8 only operates after the LKP4 6 has been cloned from the LRC4 6 10 11 1 2 3 4 5 6 7 8 9 1 Play Enter 2 Fast reverse Down 3 Previous chapter Left 4 Next chapter Right 5 Fast forward Up 6 Power Menu 7 Pause Title 8 ...

Page 9: ...e PM is used when set for 12 hour clock page 17 5 Date Month Date or Date Month page 17 6 Shared Displayed when sharing source with another zone connected to the same AM4 6 hub 7 Edit Displayed when in edit mode settings menu 8 Sleep Displayed when sleep function is set page 15 9 Learn Displayed when in learn clone mode page 18 10 Name Shows name or symbol of source or button ...

Page 10: ...nd how to set up macros as well as naming sources and buttons Second Clone the data from LRC4 6 remote into LKP4 6 keypads page 11 12 The LKP4 6 keypad does not learn IR codes directly The highlighted buttons pictured to the right are cloned to the but tons on the LKP4 6 with the same name The 1 button is cloned to the FAV 1 favorite button The names or symbols shown in the displays of the LRC4 6 ...

Page 11: ...6 and port on LRC4 6 Step 3 Put the LKP4 6 into Learn mode Press and hold the SET button Release when LEARN is displayed on the screen READY will be displayed on the screen see page 18 Step 4 Put the LRC4 6 into clone mode On the back of the LRC4 6 press the EDIT button 4 times using a paperclip or similar REC TRX will appear in the remote display 11 ...

Page 12: ...fter approximately 7 minutes the keypad should show COMPLETE for a few seconds and return to normal op eration If the cloning fails the keypad will show ERROR or TIMEOUT Wait until the remote is done sending data before repeating the process Make sure cloning cable is firmly inserted The cloning must be successful for the keypad to exit LEARN mode You can not exit LEARN mode manually Note See page...

Page 13: ...the setup and cloning you can now operate the source equipment with the LKP4 6 as well as perform various timer functions The LKP4 6 will always be in primary functions unless changed by the user Press the SHIFT button briefly to switch between primary and secondary functions of keys 1 8 The display will indicate SHIFT ON or SHFT OFF If no buttons are pressed for 30 seconds in the SHIFT ON mode th...

Page 14: ...o adjust the option Press EXIT to return to normal operation Alarm menu Hour Minute Days Source On Off 14 Days Single day Monday to Friday weekend or everyday can be selected On Off When alarm is set to on the alarm icon will appear in the display At the time set the KP4 6 LKP4 6 will turn on to the se lected source and send the FAV 1 code or macro if any ...

Page 15: ...when the LKP4 6 automatically turns off the zone or sub zone it is located in 15 Press and hold the SET button Release when SLEEP is displayed on the screen Use the and buttons to navigate the options Use the and buttons to adjust the option Press EXIT to return to normal operation ...

Page 16: ... time date and year is set automatically to the time date and year of the LRC4 6 during cloning page 11 12 Setup menu Hour Minute Month Date Year 16 Press and hold the SET button Release when SETUP is displayed on the screen Use the and buttons to navigate the options Use the and buttons to adjust the option Press EXIT to return to normal operation ...

Page 17: ... format DD MM Sets the display order of date and month LCD Brightness Can be set to bright dim or off 17 Press and hold the SET button Release when CONFIG is displayed on the screen Use the and buttons to navigate the options Use the and buttons to adjust the option Press EXIT to return to normal operation ...

Page 18: ...Power is supplied from KP4 6 with the ribbon cable incl Troubleshooting Should the keypad be locked in ERROR due to power inter ruption or other reason during cloning proceed as follow 1 Unplug power to the system and plug back in after 1 min 2 When power resumes keypad displays distorted text 3 Clone the LRC4 6 to the LKP4 6 without entering LEARN 4 When LRC4 6 is done SENDING repeat point 1 abov...

Page 19: ... normal wear and tear mis maintenance voltage variation stroke of light ning and other force major events Defects arising from incorrect installation or operation Defects arising from modification repair attempt of repair by a non authorized service center or person Defects arising form the use of non original spare parts Defects on products with altered or lacking serial number Other defects due ...

Page 20: ...www jamo com ...