background image

User Manual

Large stainless steel tank 

 

Tank capacity 6.0 L / 1.6 gallon; 

 

Tank size 32.5 x 20.5 x 9.9 cm / 12.7” x 8.1” x 3.9”

Suspendible basket

 

Patented design, basket can be raised and  

 

suspended to drain water

Drainage valve

 

Convenient to use

2 x industrial grade

 

Uniform distribution of ultrasonic waves,  

ultrasonic transducers

 

strong cleaning, high durability

2 x ceramic heaters

 

Mounted underneath the bottom of the tank for safe  

 

and even heating; more durability construction

3 x colour LED display

 

1 to 30-minute full range timer, 5 temperature settings, actual  

 

temperature thermometer, degas and solution usage timer

Independent control circuit

 

40% higher efficiency, not susceptible to  

 

for each ultrasonic transducer

 

interference, more durable

Multiple circuit protectors

 

When overloaded or improperly used, the protectors  

 

shut down the power to certain areas to protect the machine

Moisture-proofed PCB with

 

Capable for different working environments with better 

industrial IC

 

anti-interference performance

2 x cooling fans

 

One for cooling of PCB boards, one for cooling of ultrasonic 

 

transducers. Improve heat dissipation and beneficial for 

 

continuous operations

Degas feature

 

Removes air bubbles quickly

Engineering grade plastics

 

Better water-proof and drop-proof properties

Features

Professional Ultrasonic Cleaner

14/05/047-V1

Summary of Contents for ULTRA 9020

Page 1: ...rature thermometer degas and solution usage timer Independent control circuit 40 higher efficiency not susceptible to for each ultrasonic transducer interference more durable Multiple circuit protecto...

Page 2: ...4 Suspendible basket to drain water conveniently 2 x industrial grade ultrasonic transducers 2 x 55 W 110 W 2 x ceramic heaters 2 x 80 W 160 W 3 x colour LED display 1 to 30 minute full range timer 5...

Page 3: ...perate the device unattended Follow the manual to operate the device Do not use components unapproved by the manufacturer When removing the power cord from the socket grab the power plug not the cord...

Page 4: ...fore servicing or cleaning To reduce the risk of electrical shock do not put the appliance in water or other liquid Do not place or store appliance where it can fall or be pulled into a tub or sink Al...

Page 5: ...easily remove the debris 3 Biology Chemical Laboratories Labs can use ultrasonic cleaners to clean test tubes and other glass or metal containers to remove residual chemicals and debris that can affec...

Page 6: ...raditional methods 9 Special Education Institutes Kindergartens Speech therapy tools or small toys that are reused need to be cleaned to prevent the growth and spread of bacteria Ultrasonic cleaning c...

Page 7: ...ands shavers or razors Ultrasonic cleaning can clean the debris in the crevices It is quick and convenient This model has a large tank When cleaning small items the Indirect Cleaning method can be use...

Page 8: ...gears valves tools fuel injectors etc BABY ITEMS Toys baby items speech therapy tools etc SILVER COPPER OR BRASS Silverware silver copper or brass decorations etc LAB ITEMS Test tubes beakers flasks...

Page 9: ...e pipe fitting E Drainage valve handle F Control panel G Handles H Power switch I Power socket J Cover holder Indirect cleaning tank Size 21 7x18 5x7 4 cm Capacity 2 1 L Internal size 19 8x16 6x7 35 c...

Page 10: ...8 PRODUCT EXPLODED VIEW...

Page 11: ...l valve Standard part 23 Bracket ABS 24 Valve handle ABS 25 Elbow ABS 26 Inner tank ABS 27 Bottom cover ABS 28 Power PCB 1 94Vo 29 Power PCB 2 94Vo 30 Right cover ABS 31 Right down handle ABS 32 Right...

Page 12: ...ater button again dims indicating the heater is turned off 10 Working Status Green Ready G Normal working status ready to use Red Overheat R Under overheat protection 20 minutes or more of waiting tim...

Page 13: ...ton to select the temperature in the following sequence 40 C or 104 F 45 C or 113 F 50 C or 122 F 55 C or 131 F 60 C or 140 F 17 Timer Quick Set Button Press Time button LED display shows Each pressin...

Page 14: ...ower switch on Press Time button to set the timer to 10 minutes Press On Off button to start cleaning Ultrasonic waves will penetrate the container and clean the items NOTE Optional stainless steel in...

Page 15: ...r brass cartridges 3 Turn the power switch on Press Temp button to set the water temperature to 50 C 122 F Press Heater button to turn on the heater flashes Close the lid LED lights up indicating the...

Page 16: ...utes Common cleaning times are 5 10 or 15 minutes Prolonged cleaning time may result in a Loosening of the screws if used b Increasing pre existing cracks c Peeling of coating which was already separa...

Page 17: ...o speed up the mixing and to use less solution use degas function Press TIME button to set the timer to 10 minutes then press Function button illuminates Press On Off to start degassing It changes ove...

Page 18: ...r approximately 15 minutes respectively to ensure safety The unit will be disabled until it is repaired Do not run the unit for extended time or continuously The unit is designed with overheat protect...

Page 19: ...direct cleaning SPECIFICATIONS Description Professional Ultrasonic Cleaner Model ULTRA 9020 Tank Capacity 6 0 L Max 5 0 L 1 3 gallon US 1 6 gallon US Min 3 35 L 0 9 gallon US Tank Size 32 3 x 20 5 x...

Page 20: ...g your unit please call our Returns Department on 44 0 1258 822516 for a RMA Returns Materials Authorisation number Please return your unit in its original packaging along with a covering letter stati...

Reviews: