background image

www.inventer.eu

Installation instructions

iV-Smart+

Ventilation device

with heat recovery

Summary of Contents for iV-Smart Plus

Page 1: ...www inventer eu Installation instructions iV Smart Ventilation device with heat recovery ...

Page 2: ...com ponents Nevertheless deviations may still occur therefore no guarantee of compliance can be provided This documentation describes the functionality of the standard scope For reasons of clarity the documentation does not purport to cover all details on all types of the product and cannot cover every conceivable scenario for installation and assembly The illustrations in this document may differ...

Page 3: ...of supply 19 4 2 Create wall opening 20 4 3 Laying the cables to the wall opening of the ventilation device 21 4 4 Installing the wall sleeve 23 4 5 Installing the external termination of the standard ventilation device variant 26 4 6 Inserting the thermal accumulator insert 31 4 7 Electrical connection of the reversible fan 32 4 8 Check function and complete fan installation 34 4 9 Installing the...

Page 4: ...cates the severity of the potential hazard unless the preventive measures are taken DANGER means Imminent danger of serious injury or death WARNING means Possible danger of serious injury or death CAUTION means Direct danger of minor significant injury NOTICE means Direct or possible risk of property damage due to an adverse event state If you see these signs ensure you observe the described measu...

Page 5: ...ity insurance association Use the device system exclusively for the applications that are described in this documentation and only in conjunction with components that are recommended authorised and described by inVENTer GmbH in this documentation Changes or modifications to the device system are not permitted Your ventilation system is exclusively designed for use in ambient temperatures between 2...

Page 6: ...kage of the components especially the thermal accumulator NOTICE In order to avoid algae growth around the external terminations the instructions for installation must be followed exactly apply all sealing tapes We recommend a biocidal pre treatment water repellent pre treatment of the façade surface around the external termina tions Consult your planner about this NOTICE When installing component...

Page 7: ...ments without windows Qualified personnel The equipment system may only be set up operated and cleaned in conjunction with this docu mentation and the documentation for the controllers Installation electrical connection and commissioning of the equipment system may only be performed by qualified personnel Qualified personnel within the meaning of the safety notices in this documentation are person...

Page 8: ...ion reversible fan effectively reduces sound transmission The standard length of the wall sleeve is 495 mm For thicker walls a wall sleeve with a length of 745 mm can be ordered Both versions can be shortened on site The ventilation device is controlled via one of the following inVENTer system controllers1 Pure sMove inVENTer Connect2 MZ Home Components Inner cover incl ISO Coarse 60 filter Therma...

Page 9: ...ion devices iV Smart Top in the further text Top variant for integrating the external termination into the roof slope red black 2 1 Construction Figure 1 Overview iV Smart ventilation device Standard Variant Wall sleeve Thermal accumulator insert thermal accumulator and inVENTron Flair inner cover 1 Weather protection hood base plate 2 Weather protection hood cover 3 Drip rail 4 R D160 wall sleeve...

Page 10: ...extract air After 70 seconds the reversing fan changes the direction of rotation each time After the direction of rotation has changed the heat accumulator releases the stored heat energy to the incoming fresh air supply air For this principle to work correctly and to ensure pressure stability in the room the supply air volume must always correspond to the extract air volume i e at least two venti...

Page 11: ...viation at 20 Pa In order to ensure the full functioning of the ventilation device throughout the entire year a tem perature sensor is integrated into the Xenion reversible fan This measures the temperature of the air flow at the fan If the temperature at the fan falls below 5 C the reversible fan is automat ically switched to extract air mode for 4 cycles This allows the thermal accumulator to he...

Page 12: ...x 8 Multi zone control No No Operating concept Switch Touch Operating modes Heat recovery Through ventilation OFF standard version only Heat recovery Through ventilation OFF standard version only Functions Pause Function 1 h Pause Function 1 8 h Boost Function 1 h Fan speed 3 Output levels predefined infinitely adjustable 4 Output levels predefined Unit communication Cable Cable External interface...

Page 13: ...se function 1 8h per zone Dehumidification with variable air volume flow Dehumidification with variable air volume flow and other demand ventilation Pause function global and zonal Boost function global and zonal Basement ventilation Summertime ventilation Fan speed 4 Output levels freely selectable 4 Output levels freely selectable Unit communication Cable 868 MHz wireless network Cable External ...

Page 14: ...tallation location Minimum distances of the wall opening for the ventilation device Minimum distances to components building elements on the internal and external wall NOTICE Malfunction due to incorrect positioning of the ventilation device Note insulation thickness and possibly shutters Do not install near radiators Observe minimum distance of 1 2 m to adjacent air openings Termination component...

Page 15: ...g of iV Smart wall opening interior view with Smart weather protection hood top and Flex weather protection hood bottom 1 Wall opening Fig 2 left top and bottom Simplex wall installation system Fig 2 right 2 Contour of weather protection hood3 3 Reveal 4 Door window frame 5 Bottom edge of lintel4 1 Minimum distance to adjacent components on the interior wall 3 Recommendation Attach the hood at lin...

Page 16: ...of the iV Smart standard variant ventilation device Figure 3 Sectional drawing of the iV Smart ventilation device with Smart optional Flex weather protection hood A Interior plaster interior structure B Masonry C Insulation D Render 1 Inner cover base plate 2 Inner cover panel 3 R D160 wall sleeve 4 Smart weather protection hood 5 End stop tape 6 Thermal accumulator 7 inVENTron Xenion reversible f...

Page 17: ...all 3 Drip rail 4 Panel fixing screws 4x 5 Weather protection hood panel Flex weather protection hood Flex weather protection hood panel Flex weather protection hood base plate Figure 5 Dimensional drawing of Flex weather protection hood 1 Weather protection hood base plate 2 Fixing hole exterior wall 4x 3 Simplex fixing hole 4x 4 Sealing strip guide 5 Weather protection hood panel 6 Protective gr...

Page 18: ... 4 Inner cover base plate 5 Spacer 4 x 6 Interior wall fixing borehole 3 5 Dimensions Designation Depth length mm Width mm Height mm Wall opening for wall sleeve Wall thickness1 Ø180 R D160 wall sleeve 495 745 Ø160 Smart weather protection hood 43 222 285 Flex weather protection hood 23 88 279 313 Flair V 233x233 inner cover 612 233 233 1 Standard variant with render insulation masonry and plaster...

Page 19: ...n device must be carried out by qualified personnel 4 1 Check the scope of supply Check the delivery for completeness and transport damage upon receipt using the delivery note Report missing items immediately These assembly instructions describe the standard version of the product For the scope of delivery of the external termination variants wall sleeves for integrating the Connect controller pla...

Page 20: ... at all uncertain Create the wall opening through core drilling Drill with core drill attachment or milling drill Ø 180 mm additionally if flush mounted inner cover is installed chisel Requirements The masonry must be dry and in a load bearing condition No load bearing elements in the position of the drill hole Drill a wall opening Ø 180 mm at installation position of ventilation device The wall s...

Page 21: ...1 5 mm House distribution ventilation sub distribution Unit communication only if the system compo nents communicate by cable otherwise radio RS485 data cable e g Type J Y ST Y 2x2x0 8 mm Easy Connect e16 operating device Once the wall opening has been created the cables necessary for operating the ventilation system are laid to the wall opening for the ventilation device They connect the valve ga...

Page 22: ...ommunication by cable RS485 data cable Cross section 0 25 0 5 mm Length max 500 m Cable NYM J wire cross section 1 5 mm Ventilation device n Control device Connect inner cover Ventilation device 1 Control device Connect inner cover House distributor Operating device Easy Connect e16 230 V AC One after the other Star shaped Cable type LiYY 3 wire wire cross section 0 75 mm2 length see controller Ca...

Page 23: ...ver Standard A B C D A B C D 38 10 Corner A B A B 38 10 A B A B 38 UBP 10 for installation with UBP substructure panel Nordic double shell masonry clinker brick A B A B 38 C D 200 min 30 mm single shell masonry ETICS A B A B 38 C D 95 min 30 mm Requirements The wall opening Ø 180 mm is finished The cables to the wall opening of the ventilation device have been laid Determine the exact wall thickne...

Page 24: ...Accumulation of condensation water in the wall sleeve Damage to exterior wall and masonry and the building structure Attach the wall sleeve with a slope of 1 to 2 to the exterior wall Attach the wall sleeve inside and outside with the mounting wedges so that there is a slope of 1 2 to the exterior wall Check the angle of the wall sleeve using a spirit level NOTICE Contamination of the wall sleeve ...

Page 25: ... barrier levels Foam seal the gap between the wall sleeve and masonry all the way around with non pressing 2K polyurethane foam NOTICE Connect Undercover inner cov ers Leave a 30 mm gap behind the interior wall edge of the wall sleeve otherwise the housing can no longer be inserted Flair Flush with the interior wall Flush with the exterior wall Take care not to damage the connecting cable on the i...

Page 26: ...ur holes with Ø 8 mm min 50 mm deep NOTICE Installing on an unfinished exterior wall leads to damage to the exterior wall Only install the external termination once the exterior wall is finished and has fully dried NOTICE Penetration of condensation water and or algae accumulation around the external termination leads to damage to the masonry exterior wall and or discolouration of the façade Secur...

Page 27: ...This prevents the sealing tape from swelling too much and makes installation easier From the exterior wall side attach the 9 mm seal ing tape circumferentially flush with the base plate flush with the opening for the wall sleeve with 5 mm clearance along the outer edge The sealing tape must not protrude at the inner edge of the wall sleeve opening Insert the rawl plugs into the boreholes Screw the...

Page 28: ...ther protection hood from the front into the side screws blue arrows of the base plate The captive washers are located between the panel and the screw Engage the panel downwards Screw the panel firmly to the base plate with the side screws firmly to the base plate Ö The Smart weather protection hood is installed ...

Page 29: ...p tape is placed in the lower area of the wall sleeve Slide the base plate onto the projecting wall sleeve The protective grid is directed towards the floor Level the base plate using a spirit level Mark the four boreholes Outer boreholes blue arrow Masonry Inner boreholes green arrow Simplex Drill the four holes with Ø 8 mm min 50 mm deep TIP Do not apply the sealing tape until immediately before...

Page 30: ...n for fixing purposes These are not included in the scope of supply they are available as an option NOTICE If the joint between the base plate and the exterior wall is incorrectly sealed the cover cannot be fitted Seal only the upper joint between the base plate and the exterior wall Seal the joint between the base plate and the exterior wall with a permanently elastic exterior sealant Place the c...

Page 31: ...ation is fitted Remove the Styrofoam disc from the wall sleeve Insert the thermal accumulator from the interior into the wall sleeve The handle points towards the interior The connecting cables protrude into the interior From the interior slide the thermal accumulator towards the external termination as far as the end stop tape Insert the inVENTron from the interior into the wall sleeve so that yo...

Page 32: ...ting cable NOTICE Using the wrong wire end ferrules to connect the cables in the plug in connector will lead to a short circuit in the fan BUS Use wire ferrules with collars to connect the wire strands Press wire end ferrules onto the cables cable cross section 0 75 mm Loosen the plug connections on the reversible fans of the two ventilation devices Align the plug connectors on the ventilation dev...

Page 33: ...in the left pole Green cable VOUT IV in the middle pole Brown cable DIR2 V in the right pole Supply air mode Brown cable DIR2 V in the left pole Green cable VOUT IV in the middle pole White cable DIR1 III in the right pole Start direction extract air mode Start direction supply air mode The clamping screws of the plug connection are directed to the same side The connections of the white and brown ...

Page 34: ...rt direction supply air mode Direction of fan clockwise Direction of fan counter clockwise Ö inVENTron is connected and installed Plug in connector on the fan cable Plug in connector cable coming from controller Start direction extract air Start direction supply air Terminal block Colour Terminal block Meaning Colour Terminal block Meaning Colour CW Blue DIR1 III Signal direction 1 White DIR2 V Si...

Page 35: ...ound the wall sleeve Level the inner cover base plate using a spirit level Mark the four corner drill holes Drill the four holes with Ø 6 mm min 40 mm deep The assembly of any interior termination variants is not part of this documentation It can be found in the separate installation instructions for the respective inner cover the Connect controller platform Spirit level pencil drill with 6 mm bit...

Page 36: ...stall the dust filter properly to avoid a malfunction of the ventilation device Insert the dust filter into the base plate Push the filter ring firmly between the fixing tabs and the inner edge of the base plate The tab on the filter ring faces the inside and is located in the cut out provided in the base plate Place the panel on the four spacers The position arrows on the back of the inner cover ...

Page 37: ...air incl SDE 13 35 with IB Connect Standard sound level difference dB Standard 38 49 Thermal efficiency of heat recovery η w 0 87 Input voltage V DC 6 16 Power consumption W 1 3 Specific fan power input W m h 0 15 Protection class EN 61140 III Type of protection EN 60529 IP20 Standard filter filter class ISO 16890 EN 779 2012 ISO Coarse 60 G4 Sensitivity of the air flow at 20 Pa EN 13141 8 S3 Elec...

Page 38: ...uct data sheet Energy efficiency class SEC class Sound power level Lwa Maximum air flow supply air Demand controlled Manually controlled Pure with Sensors sMove with sensors Easy Connect e16 MZ Home Pure without sensor sMove without sensor 2016 1254 2014 45 dB A ENERGIA ЕНЕРГИЯ ΕΝΕΡΓΕΙΑ ENERGIJA ENERGY ENERGIE ENERGI A A A A A A A B C D E F G iV Smart iV Smart Corner iV Smart Nordic iV Smart Top i...

Page 39: ...stem regenerative g Degree of temperature change ƞt 87 h Maximum air flow rate m h 58 i Electrical input power incl control W 6 j Sound power level Lwa dB A 45 k Reference air flow m h 42 l Reference pressure difference Pa 0 m SEL W m h 0 15 n Control factor 0 65 o Internal and external transfer n a p Mixing quota n a q Position and description of the indicator for filter change Control device r I...

Page 40: ...emperature change ƞt 87 h Maximum air flow rate m h 58 i Electrical input power incl control W 6 j Sound power level Lwa dB A 45 k Reference air flow m h 42 l Reference pressure difference Pa 0 m SEL W m h 0 15 n Control factor 1 o Internal and external transfer n a p Mixing quota n a q Position and description of the indicator for filter change Control device r Instructions regarding controllable...

Page 41: ...lour 1508 0068 Flex weather protection hood white RAL 9016 1508 0157 1508 01711 Flex weather protection hood grey RAL 9006 1508 0158 1508 01721 Flex weather protection hood Nord RAL 7011 1508 0159 Flex weather protection hood anthracite RAL 7016 1508 0160 1508 01731 Flex weather protection hood custom colour 1508 0161 1508 01741 Wall sleeve with Styrofoam discs and mounting wedges Wall sleeve R D1...

Page 42: ...n in supply air mode The rotational speed of the fan is too low Increase the output level Noises Foreign body in the fan Remove foreign body from the fan Clean the ventilation device Thermal accumulator is not correctly positioned in the wall sleeve Slide the thermal accumulator out of the wall sleeve Insert it again Slide the thermal accumulator into the wall sleeve as far as the end stop tape Th...

Page 43: ...ut the warranty is available at www inventer eu guarantee 9 Service Claims Check the delivery for completeness and transport damage upon receipt using the delivery note Report missing items immediately and at the latest within 14 days to your supplier distributor or factory representative Warranty and guarantee claims In the case of a warranty or guarantee claim contact your local distributor or f...

Page 44: ...Item number 5001 0038 Version 2 0 06 2022 Subject to modifications We accept no liability for printing errors inVENTer GmbH Ortsstraße 4a D 07751 Löberschütz Germany www inventer eu ...

Reviews: