background image

 

www.insigniarange.com

 

Last Modified 01/08/2017

 

   

INSTALLATION MANUAL

 

         INS1057

 

ATTENTION INSTALLERS:

 

These instructions must be 

 

left with the customer

 

30 Day Technical Support: 

01908 226545

 

(NOTE: This service is only available to customers from the day of delivery, 

please have your supplier

s details and your postcode to hand before calling)

 
 

Replacements Parts:

 inside of your warranty contact: 

www.insigniarange.co.uk/customerservice.aspx

 

 

Spares/Replacements Parts:

 outside of your warranty 

 

contact 

0844 800 3069

 
 

www.insigniarange.co.uk

 

WARRANTY REG NO: __________________________

 

To claim your full 5 year warranty, register your shower within  90 days of delivery at:  

 

www.insigniarange.co.uk/warrantyreg.aspx. Standard 12 month warranty applies if outside this time period.

 

CHECK ALL CONTENTS BEFORE BUILD COMMENCES. NO RETURNS CAN BE MADE 
ONCE THE BUILD HAS STARTED AS IT IS DEEMED ACCEPTANCE OF PRODUCT!

 

Summary of Contents for INS1057

Page 1: ...ts Parts inside of your warranty contact www insigniarange co uk customerservice aspx Spares Replacements Parts outside of your warranty contact 0844 800 3069 www insigniarange co uk WARRANTY REG NO _...

Page 2: ...ny years to come Like everything in order to obtain a first class product that will serve you well for many years the effort and correctness put into the assembly will reflect in the quality of your f...

Page 3: ...d two methods 1 Connect within current laws and IP directives using plug and RCD provided with steam version or supply one for non steam version 2 Preferred Wire into isolated fused feed connecting di...

Page 4: ...D ELECTRICAN COMPANY TO COMPLETE THE CONNECTION FROM SHOWER TO THE HOUSE SUPPLY LAWS DEMAND IN MANY CASES YOU DO THIS AND YOUR WARRANTY IS VOID IN REGARDS TO THE ELECTRICAL ITEMS IF THIS IS NOT UNDERT...

Page 5: ...quirements Plumbing Requirements What s In The Boxes Screw Pack Contents Schematics Starting The Installation Electrical Connections Steam Generator Connections Sealing and Water Testing Sun Control P...

Page 6: ...Fixed glass 2 x Aluminium curved end posts Whilst the next steps show you how to assemble your shower we want to make sure you have a correct build to ensure you get a trouble free shower Therefore ou...

Page 7: ...re Philips Screwdriver Electric Drill Tool Requirements None Supplied Adhesive Requirements Bacteria Resistant Sanitary Silicone for vertical joints RubberGum Plumbers Mait for waste joints Not Suppli...

Page 8: ...as arrived been checked and is present No replacement missing parts can be obtained free of charge during or after the build Any claims can only be within the timescale permitted 48 hours after delive...

Page 9: ...r plumber The end delivery however must fall within the scope above Important Note Do not exceed 3 4 BAR pressure under any circumstances Warranty is void if so as damage will occur If you have a comb...

Page 10: ...www insigniarange com Last Modified 01 08 2017 10...

Page 11: ...this out as this item is for the steam generator drainage and will be connected in the instructions later Now please level the tray by firstly placing the tray in its final location and then using a s...

Page 12: ...l at the bottom take the rubber off and apply silicone inside the rubber and replace back onto the column Step 2 Place the mirrored back panel marked Right to the side glass ensuring that the side gla...

Page 13: ...ow attach the front fixed panels using ST35 screws wider rail with the Insignia logo at the top Step 5 Then screw the inner uprights into the top and bottom rails using the ST25 screws To do this you...

Page 14: ...www insigniarange com Last Modified 01 08 2017 14 Step 6 Insert the corner uprights onto the outer front fixed glass pan els as shown in the image Step 7 Now use the ST14 screws to secure into place...

Page 15: ...ete front frame to the side panels once you are happy with the alignment run a bead of silicone up the edges on the inside of the corner post and Rubber gum along the bottom of the frame Then screw to...

Page 16: ...and the bath tub and using the ST14 screws and SW9 washers fix the back walls to the roof by screwing upwards from the rear of the shower NOTE If a small gap exists silicone seal later Step 11 Screw d...

Page 17: ...ur shelf brackets and secure by tightening the grub screw situated on the bottom of the bracket Accessory Installation Please Note Ensure all grey backing film on the rear of the glass panels are pier...

Page 18: ...liding up and down Thermostatic Probe Insert the probe into the hole situated below the control panel roughly 6mm into the cabin and run clear silicone around the rear side of the probe Ozone o3 Unscr...

Page 19: ...wheels towards the track ensuring a secure a tight fit Now grease the track to ensure a smooth and long lasting operation not supplied Handles Ensuring that the inner thread is protruding out from th...

Page 20: ...e water exits from then turn off the water and swap over the relevant hose Alternatively remove the outer chrome knob by removing the chrome cap and loosening the grub screw please ensure not to unscr...

Page 21: ...www insigniarange com Last Modified 01 08 2017 21 Electric Box Steam Generator Connections Thermostatic Probe Roof Light Antenna Speaker Speaker 12V power Supply...

Page 22: ...shower Make sure these are fitted in the correct position as they are only attached for transportation reasons only Water Inlet Connect a braided hose from the shower valve s centre feed to this open...

Page 23: ...as shown below Follow the lights around in the order shown as this allows a consistent path around the entire roof and will leave you placing the last light next to the first light This is important...

Page 24: ...allow children to use the steam function This function is for ADULTS ONLY Always be aware of the steam outlet pod position Never use in close proximity to the person using it Never use this shower if...

Page 25: ...you have a small leak normally caused through insufficient sealer or air bubble on assembly dry the area thoroughly and reseal Please remember the location of the water may not be exactly where the le...

Page 26: ...e timer Button 3 Up Arrow Radio search higher frequency music track next song volume increase Button 4 Audio select To tune your radio channels firstly press the Audio Select button which looks like a...

Page 27: ...radio channels firstly press the Audio Select button which looks like a musi cal note and a Bluetooth symbol Tuning your radio channels Step1 To connect a device via Bluetooth press the music function...

Page 28: ...nlock the panel Please Note When the control panel is locked none of the buttons will work except the unlock key Button 7 Down Arrow Radio search lower frequency music track previous song volume decre...

Page 29: ...contains many useful items such as is your parts warranty registered advice on cleaning servicing your shower cabin fault finding and many more items This is a MUST to read and not just HELP It saves...

Page 30: ...ophone shower head SP185 Bath Filler SP059 Air valve operation switch SP098 Chrome air jet SP052 Whirlpool pump switch Part Code Part Description SP300 Waste hose SP187 Drain Hose SP040 steam generato...

Page 31: ...used in any way shape or form with out written permission from Maclean International Ltd Images are NOT permitted to be saved printed or uploaded Violation of copyright laws are punishable by law All...

Reviews: