background image

Operation

Manual

R

3201 Farnam Street

Omaha, NE. 68131-3406

1-800-288-1891

Summary of Contents for uvf3 10-VMHC3

Page 1: ...Operation Manual R 3201 Farnam Street Omaha NE 68131 3406 1 800 288 1891 ...

Page 2: ... for use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system To ensure proper and efficient functioning of your innowave uvf3 carefully follow the instructions contained in this manual Table of CONTENTS Specifications 3 Model and Part Designations 3 Replacement Components 3 Operational Instructions 4 Programming Instructions 5 ...

Page 3: ...SI NSF Std 42 hot and cold outlets Chlorine Reduction Particulate Reduction Taste Odor Reduction Same Limited to 0 5 gpm by the filter head installed on the 1 micron carbon block filter Model Part Designations Model Part Number Description 10 VMHC3 innowave uvf3 mini unit Hot and Cold with double cold tank technology 10 7000 Base Cabinet for innowave uvf3 10 7001 Upgrade Kit Cupholders for Base Ca...

Page 4: ...t sparkling water CO2 For Cold Water Press button 1 or Button No 2 followed by the main dispensing button Note that either Button No 1 or No 2 select cold water For Hot Water Press Button No 3 followed by the main dispensing button For Extra Hot Water Press Button No 4 wait approximately 60 seconds then press the main dispensing button This procedure will raise the hot water temperature approximat...

Page 5: ...tton No 2 repeatedly until the menu scrolls to the option Language on the display 3 Press Button No 3 to select the option 4 Press Button No 2 repeatedly to scroll down through the languages English Spanish and French 5 Press Button No 3 to select Spanish 6 Press Button No 4 to exit programming mode Programming Example Change the Language from Spanish to English and lower cold temperature to 37 F ...

Page 6: ...d water and stays on for 3 minutes 10 minutes The uv lamp lights every time you take a drink of cold water and stays on for 10 minutes UV Timer Constant The uv lamp is lit at all times when power is on C Temperatures are displayed in degrees Fahrenheit F C F Temperatures are displayed in degrees Centigrade English The display will read in English French The display will read in French Language Spa...

Page 7: ...water in pools spas 1 8 NPT Female Thread to compression Fitting Used to connect to drain fitting Safety Gloves and Protective Eyewear Caution Do not plug the unit into an electrical outlet until step 25 1 Unpack the innowave uvf3 and check exterior for damage 2 Remove the recessed screw that is located directly in front of the faucet nipple Refer to Figure 1 Removing this screw will allow access ...

Page 8: ... 7 Remove the 4 screws that secure the top cover top cover is different than the access door you opened in step 3 Remove the top cover and set aside 8 Refer to Figure 2 Remove the plastic tube that connects the outlet of the cold tank to the inlet of the top solenoid valve outlet solenoid and set aside 9 Connect a length of tubing to the outlet of the cold tank and route that tube to a sink floor ...

Page 9: ...tion 14 In the filter housing mix a 1 gallon solution of household bleach and water to make a 200 ppm concentration will require approx 1 tablespoon of household bleach The volume of the housing cannot facilitate 1 gallon of water obviously but 1 gallon of solution will ultimately be made when step 15 filling the cold tanks is performed Put the bleach in the filter housing fill with water and stir...

Page 10: ...nds for the unit to perform its diagnostics checks depress the main dispensing button on the front control panel and flush several gallons of water through the faucet to dilute and remove the sanitizer Please note A pitcher or some other setup will be required to catch the water as it flows from the faucet Any spillage of the first 2 or 3 gallons of water will effectively sanitize everything it to...

Page 11: ...urned on and sufficient time has elapsed between powering the green switch for the heater to operate approximately 10 minutes verify the hot water system is working by dispensing hot water into a cup Draining the Machine for Transport 40 If you need to drain the tanks of the innowave uvf3 please use the following precautions a Prior to draining the hot tank turn off the green compressor heater swi...

Page 12: ... 5 Connect the power cord to the back of the innowave uvf3 and to a 120volt electrical outlet 6 Turn the red power switch to the on position I On Ensure that only the red power switch is turned on and not the green compressor switch If the green compressor switch is turned on while the hot if present tank is empty damage could occur to the tank in less than 1 minute 7 Move the innowave uvf3 into i...

Page 13: ...the water to ensure that additional rinsing is not required 18 If you choose to reconfigure the temperature display and UV light settings from the original factory settings refer to the Programming Instructions section of this manual Verifying the Program Settings 19 The following defaults are programmed into the machine at the factory a Cold Temp Set 41 F b Hot Temp Set 189 F c Temp Display Rangi...

Page 14: ...this time the quartz sleeve around the UV bulb should also be rinsed off with water and wiped with a non abrasive cloth The hot tank may be de scaled or replaced if necessary 2 Check the black O ring on the quartz sleeve for any signs of wear or damage Replace as necessary 3 The filters should be replaced every 6 months or 2000 gallons whichever comes first 4 Flush 5 gallons of water through the f...

Page 15: ... clean The display indicates Hot Fault Indicates a hot tank sensor fault Check to make sure the sensor is plugged in to the main pcb properly The display indicates Cold Fault Indicates a cold tank sensor fault Check to make sure the sensor is plugged in to the main pcb properly The display indicates No Water Supply Fault will occur if the flow counter is programmed to monitored flow through the un...

Page 16: ...Operation Manual Rev NC October 1 2003 ...

Page 17: ...Operation Manual Rev NC October 1 2003 ...

Page 18: ...Operation Manual Rev NC October 1 2003 ...

Page 19: ...Insert Panel Operation Manual Rev NC October 1 2003 ...

Page 20: ...Operation Manual Rev NC October 1 2003 ...

Page 21: ......

Page 22: ...Parts Breakdown Diagram Model 10 VMHC3 UVF 10 09 00A Rev NC October 1 2003 Parts Breakdown Diagram Model 10 VMHC3 ...

Page 23: ... Twist GAC Taste and Odor 10 Micron 10 7002 6 Inside Front Support Plate Steel 10 7050 6a Frame Support Bracket Left Plastic 10 7055 6b Frame Support Bracket Right Plastic 10 7056 7 Side Panel Plastic Gray Fits Left and Right 10 7072 8 Panel Plastic Filter Access Door Gray 10 7070 9 Display PCB 10 7097 9a Cover Plastic Display PCB 10 7096 9b Screws Mounting for Display PCB 10 2151 10 Button Key Ma...

Page 24: ...ank Assembly 110V 10 7082 29a Mounting Bracket Hot Tank 10 7086 29b Mounting Hardware Hot Tank 10 7085 29c Wiring Harness Hot Tank 10 7083 30 Intentionally Left Blank 31 Insulation Hot Tank 10 7084 32 Compressor 110V 60Hz 10 2200 32a Wiring Harness Compressor 10 7093 32b Starter Relay Compressor 10 3003 32c Overload Relay Compressor 10 5018 32d Ground Wire Compressor 10 7095 33 Filter Dryer 10 708...

Page 25: ... Insert Not Sold Separately a Elbow 1 4 John Guest PN PI0308S Available from your local John Guest Supplier b Tubing Plastic 1 4 OD John Guest PN PE 08 BI 0500F N Available from your local John Guest Supplier c Elbow Plug In Type John Guest PN PI220808S Available from your local John Guest Supplier d Tee Union 1 4 John Guest PN PI0208S Available from your local John Guest Supplier e Elbow Reducing...

Page 26: ...e incorporated Parts Listing innowave uvf3 Attachment D Page 4 of 4 Drawing Item Part Description innowave Part No Unlisted Power On Off Sticker 10 5007 Unlisted Heater Compressor On Off Switch Sticker 10 5013 ...

Page 27: ...ctions innowave incorporated will replace the parts free of charge If the unit is returned to innowave incorporated for repair the purchaser shall bear the cost of freight in both directions unless the dealer and innowave incorporated agree to a different arrangement This warranty does not apply to damage caused by or resulting from shipping accident alteration misuse or abuse unauthorized or impr...

Reviews: