background image

ELECTRONICS FOR SPECIALISTS    ELECTRONICS FOR SPECIALISTS    ELECTRONICS FOR SPECIALISTS    ELECTRONICS FOR SPECIALISTS

INSTRUCTION MANUAL

COB 

LED 

Spotlight

PARC

-

1

0

0

E/

WS

Order No.

 

38.

8

0

90

Summary of Contents for PARC-100E/WS

Page 1: ...ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS INSTRUCTION MANUAL COB LED Spotlight PARC 100E WS Order No 38 8090 ...

Page 2: ...ify the shipper immediately and keep the packing material for inspection Again please save the carton and all packing materials If the fixture must be returned to manufacturer it is important that the fixture be returned in the original manufacturer box and packing 1 2 Contents Section 1 Getting Started Unpacking Safety Instructions Section 2 Set Up Installation Controlling Board Machine Connectio...

Page 3: ...at least 1m away from adjacent surfaces Be sure that no ventilation slots are blocked Fixture may carry high heat do not aim at objective exceeding 2 minutes Safe wire should be used to install machine Bearing of safe wire should be 3 times of the machine weight Always disconnect from the power source before servicing or replacing fuse lamp and be sure to replace with same fuse lamp size and type ...

Page 4: ... and wire it between pins 2 3 of the last fixture They are also readily available from specialty retailers Complimentary signal cable can transmits signals to 20 unit fixtures at most Signal amplifier is a must to connect more fixtures and must weld a 120 ohm 1 4 watt resistor and wire it between pins 2 3 of the last fixture 5 6 Controlling Board The display is blackout automatically if there is n...

Page 5: ... Bad data link connection Inspect cables and correct poor connections and or broken cables Conflict between tracking and vector control Eliminate scene cross fade on controller Data link not terminated Insert termination plug in output of last fixture Defective fixture or 2 devices transmitting on link Bypass fixtures one at a time until normal operation is regained unplug both connectors and conn...

Page 6: ...iter system is independent with detective fan working system DMX Protocol 3CH Channel Function Effect 1 Dimmer 0 255 White linear dimmer from dark to light 2 Strobe 0 1 No applicable 2 255 strobe speed from slow to fast 10 Dimmer Curve Power Limiter 0 20 standard dimmer curve 21 40 dimmer curve 1 41 60 dimmer curve 2 61 80 dimmer curve 3 81 100 dimmer curve 4 101 149 N A 150 155 3 second interval ...

Page 7: ...l fixtures same addresses value or subject to DMX console performance Attention all fixtures use the same DMX channel 3 or 1CH Specifications Power supply Operating voltage Power consumption operation Wattage Light source Strobe Dimmer Cooling Admiss ambient temp Beam angle Control mode Channels Net weight Dimensions Connections 230 V 50 Hz 160 VA 230 V 160 VA 100 W 1x 100 W COB LED cool white 700...

Reviews: