background image

Rhein Tech Laboratories 

Client: 

IKUSI – Angel Iglesias 

360 Herndon Parkway  

 Model: 

R70MP10 

Suite 1400 

Standards: FCC 

15.249/IC 

RSS-210 

ID’s: 

PVT-R70MP10 & 4166A-R70MP10 

Herndon, VA 20170 
http://www.rheintech.com Report 

#: 

2007115 

 

 

 

Page 22 of 34  

 
 
 
 

Appendix I: 

Manual 

 

Please see the following pages. 

 

Summary of Contents for 70-MINI

Page 1: ...ngel Iglesias 360 Herndon Parkway Model R70MP10 Suite 1400 Standards FCC 15 249 IC RSS 210 ID s PVT R70MP10 4166A R70MP10 Herndon VA 20170 http www rheintech com Report 2007115 Page 22 of 34 Appendix I Manual Please see the following pages ...

Page 2: ... 00 01 07 120009 0B pdf IKUSI se reserva el derecho de modificar esta información sin previo aviso 70 MINI V 01 00 01 07 120009 0B pdf IKUSI reserves the right to modify this information without prior notification ENGLISH ...

Page 3: ...TENANCE TROUBLESHOOTING 9 5 RECEIVERS 10 5 1 TYPE OF RECEIVERS 10 5 2 MAINTENANCE TROUBLESHOOTING 11 6 RADIO REMOTE SYSTEM FUNCTIONALITIES 12 6 1 GENERALS 12 6 2 BATTERY LEVEL INDICATION 12 6 3 BASE CHANNEL CHANGING T70MG10 T70MH3D T70MH3 T70MH2 TRANSMITTER MODELS 13 6 4 ID RELEASING T70MG10 T70MH3D T70MH3 T70MH2 TRANSMITTER MODELS 15 6 5 AUTO TEACHING MODE T70MG10 T70MH3D T70MH3 T70MH2 TRANSMITTE...

Page 4: ...MHz 870MHz 433MHz 419MHz RF Power ERP 1mW 915MHz 5mW 870 MHz 10 mW 433MHz 10mW 419MHz Modulation type FSK 4800 bps and 7 200 bps Protection IP65 Channel bandwidth 25KHz Number of IDs 64K per band Response time 150ms Working channel selection Automatic at transmitters start up Display option for Remote Tele Alignment 2 lines x 12 characters line icons Antenna Printed circuit board integrated standa...

Page 5: ... power supply range Electrical input protection Fuse protected Electrical output protections Polarity inversion Shortcircuit Operating temperature 20ºC 70ºC Storage temperature 24h 25ºC 75ºC Storage temperature long periods 25ºC 55ºC Disconnecting security A MOSFET transistor connected with the positive value of the power supply provides security functions R70MR11 Receiver with relays outputs 11 o...

Page 6: ... Vin 115V AC 50 60Hz 20 30 Vin 230V AC 50 60Hz 20 30 Vin Number of outputs 06 RELAYS MODEL CE hoisting applications Cat 3 EN 954 1 06 relays outputs 3 Hoist 3 Travel Protection IP65 Antenna Printed circuit board integrated standard Working channel selection Automatic at transmitters start up Weight 640 grs Dimensions Length 151 mm Wide 129mm Height 61mm EEPROM Internal Status signaling MultiLED 7 ...

Page 7: ...olled Identify the machine which the transmitter corresponds to Carry out regular checks and preventive maintenance In the case of repairs only use original spare parts Never modify the device without prior study and approval of the manufacturer Never use the device with a power supply other than the indicated Never allow the device to be used by unqualified people After being used do not leave th...

Page 8: ...rection indicated by the arrow 3 Procedure for closing the mechanism of the battery housing This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Changes or modifications not expressly ap...

Page 9: ... reserves the right to modify this information without prior notification 3 2 RECEIVER Find an easy access location for the receiver free from obstacles in order to facilitate the reception of the transmitter s radio signal and far away from elements which can produce intense electric disturbance R70MP10 and R70MR06 models receiver dimensions R70MR11 model receiver dimensions ...

Page 10: ... STOP function The transmitter remains powered 3 Enter the key code press simultaneously functions 4 Press START 5 Transmitter in ON state solid green LED Turning on the T70MH3D transmitter model 1 Insert the transmitter s batteries 2 AA type batteries 2 Press ON STOP function LCD display message PLEASE WAIT 3 Enter the key code press simultaneously functions LCD display message PRESS START 4 Pres...

Page 11: ...ut prior notification 4 TRANSMITTERS 4 1 Transmitters MODELS The models with LCD display are always required for Tele Alignment purposes Generic máx 10 functions 1 step ON OFF without display Hoisting máx 6 functions 2 steps 2 AUX A1 and A2 1 step START ON STOP Hoisting máx 6 functions 2 steps START ON STOP with display Hoisting Cat 3 EN 954 1 máx 4 functions 2 steps START ON STOP without display ...

Page 12: ...ITCHED OFF mode after 4 minutes Without signal Red LED and buzzer continuously activated LOST Without signal Without signal Switches to SWITCHED OFF mode Buzzer bips during 1 minute Red LED and buzzer continuously activated PASSWORD Orange solid LED Without signal Switches to SWITCHED OFF mode Without signal Red LED and buzzer continuously activated AUTOID Orange LED Without signal Switches to SWI...

Page 13: ... of transmitter s breakdown The ID release can be also performed from the transmitter with a special function RL 1 Power supply plug in terminals 24 48 115 and 230 V AC Please note see table the right fuse values depending on the input voltage RL 2 Plug in identified connection terminals 1st and 2nd speed K1 K11 and START relay RL 3 Plug in terminal for connecting the STOP relay NO Cat 3 EN 954 1 ...

Page 14: ...lace the electronic board Blinking fast wrong EEPROM checksum Data corrupted Reprogramme EEPROM SIGNAL GREEN LED Off if no radio signal detected Squelch LED On and the transmitter switched Off indicates occupied radio channel LED On and DATA switched Off indicates radio channel occupied by a non IKUSI system Verify transmitter s radio and battery DATA GREEN LED Off if a wrong frame is received Bli...

Page 15: ... LED blinking and intermittent buzzer s sound pulses of 0 1 sec every 0 9 sec __ _____________ ________ The transmitter models without LCD display have restrictions with the access to the programation parameters due to the impossibility to show the Software Menu in Programation Mode The remote system receiver remembers the last ID used by the last current working transmitter This transmitter can b...

Page 16: ...as the number of units of ten of the new base channel Note To programme channels from 1 to 9 do not press this function equivalent to 0 value Press function 2 as many times as the number of units of the new base channel 6 Updating and sending the new base channel data to the receiver orange LED blinking 7 Once the new base channel is recorded in the receiver the transmitter switches to OFF mode Or...

Page 17: ...e the base channel With DOWN function choose the units of the new channel Nota 0 to programme channels from 1 to 9 With UP function choose the number of units of ten of the new channel 5 To validate the new channel press START The new channel information will be displayed in the LCD Freq Change Channel __ 01 02 03 MAXCAN NN 01 02 03 MAXCAN MAXCAN 11 in 870 MHz MAXCAN 69 in 433MHz and 915MHz 1 With...

Page 18: ...0MG10 TRANSMITTER MODEL It allows releasing the receiver s ownership of the working transmitter 1 With the transmitter switched off press ON OFF Transmitter in stand by or LOW CONSUMPTION mode 2 To enter in LIB ID mode press simultaneously 4 and 10 functions DURING THE ID RELEASING PROCESS THE ORANGE LED BLINKS AND THE BUZZER IS ACTIVE ID RELEASED PROCESS FINISHED LED OFF and BUZZER OFF T70MG10 TR...

Page 19: ...ntil the orange LED lights continuously The orange LED switches on off when every password value is pressed At the validation process the orange LED blinks indicating that the new values are being recorded into the receiver Once the operation has finished the orange LED switches off and the transmitter switches to stand by or LOW CONSUMPTION mode PASSWORD DEFAULT VALIDATE Note In two steps pushbut...

Page 20: ...ed pressing the first step T70MH2 TRANSMITTER MODEL SWITCHED OFF or LOW CONSUMPTION MODE 1 With the transmitter switched off press ON STOP Transmitter in stand by or LOW CONSUMPTION mode 2 To enter in SEARCH mode press simultaneously ENTER and START functions 3 Entering ENTER DOWN ENTER function s sequence the SEARCH function will execute 4 Pressing START the transmitter switches to stand by or LO...

Page 21: ...s aprox and the transmitter switches to PARAM mode ready to select a new sequence DOWNLOAD LOCAL or UPLOAD LOCAL or DOWNLOAD REM 2 In case of Grave Error the red LED and the buzzer becomes active continuously 3 The beginning of the EEPROM updating process is signalized with orange LED blinking in different ways 4 The right ending of the EEPROM updating process is signalized with green LED continuo...

Page 22: ...s DOWNLOAD REM UPLOAD LOCAL DOWNLOAD LOCAL Keep pressed until the orange LED lights continuously STAND BY or LOW CONSUMPTION MODE Note In two steps pushbutton keypads the special functions are activated pressing the first step Note In two steps pushbutton keypads the special functions are activated pressing the first step T70MH2 TRANSMITTER MODEL 1 With the transmitter switched off press ON STOP T...

Page 23: ...played in the LCD I N I T I A L I Z I N G P L E A S E W A I T This message will remain in the LCD display when reading the internal EEPROM Finally the transmitter will switch off remaining in switched off mode no message will be displayed only the battery level icon will be displayed __ ___ _____ different battery level indications full medium low and empty SEQUENCE TO ACCESS TO PROGRAMATION MODE ...

Page 24: ...iso 21 70 MINI V 01 00 01 07 120009 0B pdf IKUSI reserves the right to modify this information without prior notification 6 8 1 PROGRAMMING MODE BLOCK DIAGRAM PROGRAMATION 1 PARAMETERS 2 TELETEACH 3 SEARCH 1 0 DOWNLOAD LOC 1 1 UPLOAD LOC 1 2 DOWNLOAD REM WAIT PLEASE 2 1 RESET VALUES CONFIRM RESET 2 0 ADJUST SERCHING LOST EMITTER ...

Page 25: ... information without prior notification 2 0 ADJUST 2 0 0 PASSWD ID 2 0 1 SEARCHMODE 2 0 2 TOUT LATENCY 2 0 3 TOUT OFF 2 0 4 T STOP 2 0 5 TELEALIGN PASSWD ID XXXX SERACH MODE ON OFF TOUT LATENCY MIN N TOUT OFF MIN NN T STOP SEG NN N SELECT OUT 1 10 SELECT OUT START 2 0 5 START OUT MODE OUT MODE LATCH TEMP The START relay activation can be programmed as MOMENTARY or LATCHING as well while pressing S...

Page 26: ...ate TOUT OFF 15min 10 to 20min step of 1 min and infinite INF value Time from LATENCY state to SWITCH OFF state TSTOP 2sec 1 to 10sec steps of 0 1sec Passive STOP time OUTMODE MOMENTARY MOMENTARY or LATCHING OUTPUTS OPERATING MODES SOFTSTART ON ON or OFF Enable or Disable soft start SOFTSTOP ON ON or OFF Enable or Disable soft stop ACCELRAMP 0 1sec 0 0sec 0 1sec 0 2sec 0 3sec 0 4sec 0 5sec 0 6sec ...

Page 27: ...P UP PROGRAMMING RAMP ON ME ON ME ON OFF Press again the active order or press ON OFF ME ON Press one order V MAX 100 2 ON OFF PROGRAMMING RAMP OFF RAMP OFF V MAX 100 RAMP ON T1 T2 V MAX 100 In MOMENTARY mode the outputs remain actives while the orders are pressed They can be programmed in ramp mode soft start and soft stop programmable independently or ON OFF mode MI Whatever 10 functions or gene...

Page 28: ...EED ON V OUT XX VOUT PROGRAMMABLE VALUE BY EEPROM XX TI PROGRAMMABLE TIME 1 VEL SPEED ON V OUT 0 2 VEL SPEED ON V OUT XX 2 VEL SPEED OFF V OUT XX 1 VEL SPEED OFF V OUT 0 For two steps keypads the 2nd speed value is V max 100 The 1st speed value is Vout and is programmable Tele aligned XX For two steps keypads the 2nd speed value is V max 100 The 1st speed value is Vout and is programmable Tele ali...

Page 29: ...ax 61 3 9720 7422 ika ikusi com CHILE INGENIERÍA IKUSI CHILE LTDA Tel 56 2 335 9661 Fax 56 2 233 7511 ikc ikusi com FRANCE IKUSI FRANCE SARL Tel 33 1 43 03 52 22 Fax 33 1 43 03 52 42 ikf ikusi com MEXICO IKUSI GS MÉXICO S A DE C V Tel 52 55 5663 8600 Fax 52 55 5663 8684 contacto ikusi gs com mx PERU ÁNGEL IGLESIAS S A SUC DEL PERÚ Tel 51 1 211 6500 Fax 51 1 442 2073 ikpe ikusi com PORTUGAL IKUSI E...

Page 30: ... 00 01 07 120009 0B pdf IKUSI se reserva el derecho de modificar esta información sin previo aviso 70 MINI V 01 00 01 07 120009 0B pdf IKUSI reserves the right to modify this information without prior notification ...

Page 31: ... 00 01 07 120009 0B pdf IKUSI se reserva el derecho de modificar esta información sin previo aviso 70 MINI V 01 00 01 07 120009 0B pdf IKUSI reserves the right to modify this information without prior notification ...

Page 32: ... 00 01 07 120009 0B pdf IKUSI se reserva el derecho de modificar esta información sin previo aviso 70 MINI V 01 00 01 07 120009 0B pdf IKUSI reserves the right to modify this information without prior notification ...

Page 33: ... 00 01 07 120009 0B pdf IKUSI se reserva el derecho de modificar esta información sin previo aviso 70 MINI V 01 00 01 07 120009 0B pdf IKUSI reserves the right to modify this information without prior notification ...

Reviews: