Safety Rope Switches from IDEM 

 

                                                                

Data Sheet         Guardian Line Series               

 
 
 

 
 
 
 
 

          

 

 
 

 

 
Using Safety Rope Emergency Stop Switches  

Application:

 

Safety Rope Emergency Stop Switches are mounted on machines and sections of plant conveyors which cannot be protected by guards. In contrast to traditional 
mushroom head type Emergency Stop buttons, Safety Rope Switches can initiate the emergency command from any point along the installed rope length. 
In combination with any dual channel safety monitoring controllers IDEM Safety Rope Systems can be used as emergency stop devices and monitored for up to                  
Category PLe/Cat.4 to ISO13849-1. It is the responsibility of the user to ensure the correct overall functionality of its systems and machines. IDEM, its subsidiaries and 
affiliates, are not in a position to guarantee all of the characteristics of a given system or product not designed by IDEM.

 

Operation:

 

All IDEM Safety Rope Emergency Stop Switches conform to Standards ISO13850 and IEC60947-5-5. They have a positive mechanical linkage between the switch contacts 
and the wire rope as per IEC60947-5-1. The emergency stop switches are brought into the operational condition by pre-tensioning the rope by use of a tensioner/gripper 
device which clamps the rope and then hooks to the switch eyebolts. Correct tension can be observed by viewing the tension indicator on the switch housing. Once 
tensioned the switch contact blocks can be set to the operational condition (safety contacts closed, auxiliary contacts open) by pressing a blue reset button on the switch 
cover. 
 
All of the Safety Rope Switches have wire-breakage monitoring. On pulling or breakage (tension loss) of the rope, the safety contacts are positively opened and the auxiliary 
contacts are closed. The switches are mechanically latched and can then only be returned to the operating condition by pressing the reset button as required by ISO13850. 

Installation Guide: 

   

                                                                                                                                                                                                               

1. Installation of all IDEM Safety Rope Switch systems must be in accordance with a risk assessment for the individual application. Installation must only be carried out by 
competent personnel and in accordance with these instructions. 

 

2. According to ISO13850 pulleys may only be mounted such that a complete length of the rope can be observed.  
 
3. Rope support eyebolts must be fitted at 2.5 m. min. to 3m. max. intervals along all rope lengths between switches.

 

The rope must be supported no more than 500mm 

from the Switch eyebolt or Safety Spring (if used). It is important that this first 500mm is not used as part of the active protection coverage. 
 
4. M5 mounting bolts must be used to fix the switches. Tightening torque for mounting bolts to ensure reliable fixing is 4 Nm. Tightening torque for the lid screws, conduit 
entry plugs and cable glands must be 1.5 Nm to ensure IP seal. Only use the correct size gland for the conduit entry and cable outside diameter. 
 
5. Tensioning of rope is achieved by use of IDEM tensioner/gripper assemblies. 
 
On installation set the tension to the mid position as indicated by the markers in the viewing window of each switch. Check operation of all switches and the control circuits 
by pulling the rope at various locations along the active protection area and resetting each switch by depressing the Blue Reset button. Ensure each time that the switches 
latch off and require manual resetting by depressing the blue reset button. Increase the system tension further, if required, depending upon the checks along the active 
length of coverage.  
 
If fitted with a Mushroom type E-Stop button (Red) then test and reset each switch to ensure correct function of the safety control circuits.  
 
Typical operational condition for successful operation of the system is less than 75N. pulling force and less than 150mm deflection of rope between eyebolt supports. 
 
6. Maintenance: 

 

Every Month:

        Check correct operation of system at locations along all coverage length.

  

Check for nominal tension setting, re-tension rope if necessary. 

Every 6 Months:

   Isolate power and remove cover.

 

Check screw terminal tightness and check for signs of moisture ingress. Never attempt to repair any switch.  

 

 

 
 
 
 
 
 
 

 

 

 

 

                              

 

              

Heavy Duty Types: GLHD (Dual Head)                GLHR/L (Single Head)             Standard Duty Types:  GLS               Mini Duty   Type: GLM  

                                             GLHD-SS (Dual Head)          GLHR/L-SS (Single Head)                                            GLS-SS                                     GLM-SS

 

Original Instructions. 

 
To request this data sheet in other languages please contact 

[email protected]

 

Um dieses Datenblatt in Deutscher Sprache wenden Sie sich bitte anfordern 

[email protected]

 

Pour obtenir cette fiche en Français, veuillez contacter 

[email protected]

 

Para solicitar esta hoja de datos en Español, por favor contacto con 

[email protected]

 

 

   

WARNING:  DO NOT DEFEAT, TAMPER, OR BYPASS THE SAFETY FUNCTION.   

                                        FAILURE TO DO SO CAN RESULT IN DEATH OR SERIOUS INJURY.  
 
         AVERTISSMENT: NE PAS DESACTIVER, MODIFIER, RETIRER, OU CONTOURNER  
                                       CETI INTERVERROUILLAGE IL PEUT EN RESULTER DES   
                                       BLESSURES GRAVES DU PERSONNEL UTILISATEUR.   

Summary of Contents for Guardian Line Series

Page 1: ...engths between switches The rope must be supported no more than 500mm from the Switch eyebolt or Safety Spring if used It is important that this first 500mm is not used as part of the active protection coverage 4 M5 mounting bolts must be used to fix the switches Tightening torque for mounting bolts to ensure reliable fixing is 4 Nm Tightening torque for the lid screws conduit entry plugs and cabl...

Page 2: ... open Contact closed EX 2NC 1NO 3NC 1NO 2NC 2NO 4NC 4NC 2NO Latched off Rope Slack Tension Range Switch Reset Rope Pulled NC 11 12 11 12 11 12 11 12 11 12 21 22 21 22 21 22 21 22 21 22 31 32 31 32 41 42 41 42 51 52 NO 33 34 43 44 33 34 33 34 43 44 63 64 GLM 30m with Safety Spring GLM 50m GLS 80m GLS SS 100m GLHD 200m with Safety Springs GLHD L R 250m 0mm 3 5mm 14 5mm 17 0mm ...

Page 3: ...at 100mA load up to Category 4 with Safety Relay up to PLe depending upon system architecture up to SIL3 depending upon system architecture 8 cycles per hour 24 hours per day 365 days MTTFd 214 years GLH shown GLS GLM shown 9 To fit Mushroom type Emergency stop Buttons a Remove M12 threaded plug from the mounting port b Apply thread locking solution to the threads of the E Stop mechanism c Insert ...

Page 4: ...D Steady Green Steady Red 24V dc LED Steady Green Steady Red 110 120V ac LED Steady Green Steady Red 230V ac 140044 140144 E Stop Mechanism Standard E Stop Mechanism Stainless Steel 140043 Safety Spring 220mm long Sales Number Galvanised Stainless Steel Description Rope Eyebolts Tensioner Gripper S S Allen Key 140001 140010 5M Rope Kit 5M QL 3 1 1 140002 140011 10M Rope Kit 10M QL 5 1 1 140003 140...