background image

MINIMAG

RS-232

User’s Manual

TM

Summary of Contents for MiniMag RS232

Page 1: ...MINIMAG RS 232 User s Manual TM...

Page 2: ...le for a Class A computing device Limited Warranty ID TECH warrants this product to be in good working order for a period of one year from the date of purchase If this product is not in good working o...

Page 3: ...not neces sarily mean it will appear on the screen as if it were entered manu ally Use the MiniMag Configuration UtilityApplication to program the reader and a communication program such as Procomm or...

Page 4: ...e host system These settings are programmed into the reader using the MiniMag Configuration Utility Program or by sending Setup Commands from the host application to the reader Once programmed these c...

Page 5: ...Change To Default Settings STX S 18h ETX CheckSum This command does not have any FuncData It returns all settings for all groups to their default values Data Editing will be turned off and the formula...

Page 6: ...for this function FuncSETBLOCK are in the order of their Function ID FuncID MSR Reading Settings Turn the MiniMag on or off If the reader is disabled no data will be sent out to the host STX S 1Ah 01...

Page 7: ...tting Terminator characters are used to end a string of data in some applications STX S 21h 01h Terminator Settings ETX CheckSum Terminator Settings 0 CR LF 1 CR 2 LF 3 None Preamble Setting Character...

Page 8: ...tinel And Track 2 Account Number Only The MiniMag can be set to either send or not send the Start End sentinel and to send either the Track 2 account number only or all the encoded data on Track 2 The...

Page 9: ...mat Track Data STX ESC magnetic stripe data CR ETX Where STX Start Text ETX End Text SS Start Sentinel Track1 ISO AAMVA CA DMV Track2 ISO AAMVA CA DMV Track3 ISO Track3 AAMVA Track3 CA DMV Handshaking...

Page 10: ...host in any order desired regardless of the order in which they occurred in the card track Insert Character Strings into the Output Data Record Character strings can be defined and inserted at any pl...

Page 11: ...By separating the input data record into smaller blocks called fields each block can be edited individually Additional fields can also be added to the record allowing specific functions such as carri...

Page 12: ...ntaining the character string Up to six fields can be defined The maximum number of characters for each field is six Search Method In working with a user defined format that is not credit card CA DMV...

Page 13: ...earch Before Search Between and Search After These rules help define a new flexible field With Search Before all the data in the new generated field comes before the specified string after the specifi...

Page 14: ...the data in the new generated field comes between the two specified strings for the specified track For example a new field can be defined in which the data comes between the first searched separator...

Page 15: ...ntinel CDL Old California Drivers License format Note The CR commands shown above for Tracks 1 2 and Tracks 2 3 denote the default character for this position the Track Separator position The CR LF co...

Page 16: ...reamble string will result in ab cd as the preamble Default Setting Table Setting Default BeepVolume High MSR Reading Enable Decoding Method Both Swiping Direction Terminator Settings CR Preamble Sett...

Page 17: ...tinel 1 j Linear Redundancy Check LRC Character 1 Track 2 a Start Sentinel 1 b Account Number 13 or 16 c Separator 1 d Expiration date YYMM 4 e Optional discretionary data variable f End Sentinel 1 g...

Page 18: ...ormat Track 1 a Start Sentinel 1 b Format Code Type 1 C Commercial S Salesperson D Driver I Identification R Senior Citizen c Name Line 1 29 d Name Line 2 29 e Address Line 1 29 f City 13 g End Sentin...

Page 19: ...q End Sentinel 1 r Linear Redundancy Check LRC Character 1 AAMVA Driver s License Format Track 1 a Start Sentinel 1 b State or Province 2 c City 13 d Name 35 e Address 29 f End Sentinel 1 g Linear Red...

Page 20: ...reader Operation To install the MiniMag Configuration Utility please follow these steps 1 Run Windows 95 98 or Windows NT 2 Run SETUP from the MiniMag Configuration Utility Disk 3 Follow the instruct...

Page 21: ...SaveAs dialog box so you can name your file CONTEXT HELP Use the Context Help command to obtain helponanyaspectoftheMiniMagConfigurationUtility The HELPtopicwillbeshownfortheitemyouclicked USING HELP...

Page 22: ...on settings at their default values FILE SAVE AS dialog box The following three options allow you to specify the name and location of the file you are about to save 1 FILE NAME Type a new file name to...

Page 23: ...ID TECH Inc 655 N Berry Street Suite G Brea California 92821 714 990 1343 www idt net com 80030501 004 R8 00 420...