DL-1xxS-WF Series User’s Manual

 

 

DL-1xxS-WF Series 

User’s Manual (Rev1.0,May/2022) ------------- 1

 

www.icpdas.com 

 
Warranty 

All  products  manufactured  by  ICP  DAS  are  under  warranty  regarding 

defective  materials  for  a  period  of  one  year  from  the  date  of  delivery  to  the 
original purchaser. 
 
Warning 

ICP  DAS  assumes  no  liability  for  damages  resulting  from  the  use  of  this 

product. ICP  DAS reserves the right to  change this  manual  at  any time  without 
notice.  The  information  furnished  by  ICP  DAS  is  believed  to  be  accurate  and 
reliable. However, no responsibility is assumed by ICP DAS for its use, or for any 
infringements of patents or other rights of third parties resulting from its use. 
 
Copyright 

Copyright 2022 by ICP DAS. All rights are reserved. 
 

Trademark 

The names used for identification only may be registered trademarks of their 

respective companies. 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for DL-1 S-WF Series

Page 1: ...es resulting from the use of this product ICP DAS reserves the right to change this manual at any time without notice The information furnished by ICP DAS is believed to be accurate and reliable Howev...

Page 2: ...DL 1xxS WF Series User s Manual DL 1xxS WF Series User s Manual Rev1 0 May 2022 2 Document Revision Version Date Description of changes Rev1 0 2021 03 08 First release for DL 1xxS WF Series...

Page 3: ...5 2 Digital Output DO wiring 13 2 5 2 Power Input 13 3 Software 14 3 1 DL WF PC Utility DL Series Android APP 14 3 1 1 Main Screen 14 3 1 2 Device Status 15 3 1 3 Sensor DO Output status 15 3 1 4 Icon...

Page 4: ...me data can be accessed from anywhere and at any time using the PC Utility Android APP Web It includes 2 channel Photo MOS Relay Output using trigger source and range for Alarm Devices DL 101S WF incl...

Page 5: ...tible with IEEE 802 11b g n standards DL 1xxS WF complied with IEEE 802 11b g n standard from 2 4 2 5 GHz and it can be used to connect your wireless LAN Support Access Point AP Station STA modes for...

Page 6: ...000 downloadable records CSV able to be stored Each segment file size is 64Kbyte for 5376 record Chart View for PC Utility Android APP The DL WF Series PC Utility DL Series Android APP can be used to...

Page 7: ...cy Typical 0 4 C refer to figure 2 Relative Humidity Measurement Range 0 to 100 RH Resolution 0 1 RH Accuracy Typical 3 RH 20 80 RH refer to figure 1 LCD Display Display Information Date Time Temperat...

Page 8: ...ESD IEC 61000 4 2 8 kV Air for Random Point EFT IEC 61000 4 4 4 kV for Power Environment Operating Temperature 20 60 C Storage Temperature 30 80 C Humidity 5 to 95 RH Non condensing Mechanism Dimensi...

Page 9: ...eries User s Manual DL 1xxS WF Series User s Manual Rev1 0 May 2022 9 2 Hardware 2 1 Outward Appearance Figure 2 1 DL 101S WF DL 111S WF 2 2 Reset to Default Figure 2 3 Switches inside the cover Reset...

Page 10: ...e the cover on the left side Big cover Press hold the Reset button on the bottom side over 6 Sec until the Red LED Status Alarm quick flash then release to restore device default setting Default is se...

Page 11: ...0 May 2022 11 2 4 LCD Display Only for DL 101S WF There are 6 items Date Time Temperature C and F Relative Humidity RH Dew Point for LCD display it can select On or Off to show on each item using uti...

Page 12: ...Rev1 0 May 2022 12 2 5 Dimensions The diagrams below provide the dimensions of the DL 1xxS WF series to use in defining your enclosure specifications All dimensions are in millimeters Figure 2 4 Dime...

Page 13: ...xS WF Series User s Manual DL 1xxS WF Series User s Manual Rev1 0 May 2022 13 2 6 Wire Connection 2 6 2 Digital Output DO wiring Figure 2 6 Photo MOS Output wiring 2 6 2 Power Input Figure 2 7 Power I...

Page 14: ...series It is available on both Windows Android application to operating and configure the DL 1xxS WF device PC Utility Support Windows 7 or later versions and Android 5 0 or later versions The follow...

Page 15: ...Rev1 0 May 2022 15 3 1 2 Device Status Show the connected controller information user define Locate string RSSI strength Device IP Static IP button for changing device IP in STA mode 3 1 3 Sensor DO...

Page 16: ...m Only DL 101S WF 2 For Android APP Function button is including inside Menu bar Offset Offset adjustment only for Android APP PC Utility HTML is show as number box Data Log Chart 1 PC Utility Data Lo...

Page 17: ...vice take effect on new setting AP SSID Name 1 Default Controller s SSID in Wi Fi AP mode will be DL 1xxS WF xxxxxx Note xxxxxx is the last 6 characters MAC address of your device Key Type AP mode SSI...

Page 18: ...168 77 1 AP mode support only one connection If Multiple devices connect at a same time only first connected devices can access STA Station DL Device will auto connect to specific Wi Fi AP PC or Andr...

Page 19: ...s Manual Rev1 0 May 2022 19 3 1 6 IP Scanner There are lots of free IP scanner tools in both Windows Android OS for example Advanced IP Scanner for Windows Network Analyzer for Android those are high...

Page 20: ...Time when select Data Logger running in Schedule mode Sampling Interval Select the interval time for sampling 5 10 15 30Sec 1 5 10 15 30Min 1 12 24Hr Digital Output Control DO0 DO1 Trigger Source Sel...

Page 21: ...oll Select Horizontal Timeline Vertical Value direction on Chart View use mouse wheel for Zoom In or Zoom Out Live Chart Check on Live Chat select the interval time to draw the real time chart Log Man...

Page 22: ...f registers Function Code Descriptions 01 0x01 Read multiple Coil Status 03 0x03 Read multiple Analog Output registers 04 0x04 Read multiple Analog Input registers 05 0x05 Force Single Coil 06 0x06 Wr...

Page 23: ...Binary A binary item is represented as a single bit within a data word All binary is packed into 16 bits data words which are accessed using function code 01 and 02 Therefore a single register contain...

Page 24: ...TCP Application Data Unit 4 3 1 MBAP The Modbus TCP extension includes 7 additional bytes to the original Modbus protocol which allows for transport over the TCP IP layers A dedicated header is used o...

Page 25: ...1 Always 1 Read Modbus Idle Timeout value Unsigned Int16 R Table 4 7 FC03 Read multiple AO address 4xxxx Note Offset value will multiply by 0 1 E g Read value 10 the offset will be 10 0 1 1 0 Address...

Page 26: ...ccess Type 40001 1 Write Temperature offset Int16 W 40002 2 Write Relative Humidity RH offset Int16 W 40003 3 Write Illumination Lux offset Int16 W 40011 11 Write Modbus Idle Timeout value Unsigned In...