background image

OSR

IBM 4033/Lexmark MarkNet

 

Models 001, 002, 003, 011, 012, and 013:

Adapter

Models 201, 301, 202, and 302:

Models

0XX, 2XX, 3XX

Network Operating System Requirements

IBM 4033 Models 1, 2, and 3: IBM OS/2 LAN Server 1.2,
1.3, and 2.0; Microsoft LAN Manager 2.0 and 2.1; IBM
AIX for RISC System/6000  Version 3.1.5

IBM 4033 Models 11, 12, and 13: Novell Netware 2.2 and
3.11; Netware from IBM 2.2 and 3.11; Netware for
AIX/6000  from IBM Version 3.11

Connectivity

IBM 4033 Models 1 and 11: IBM Token-Ring (IEEE
802.5)

IBM 4033 Models 2 and 12: Ethernet 10BaseT (IEEE
802.3)

*

IBM 4033 Models 3 and 13: Ethernet 10Base2 and
10Base5 (IEEE 802.3)

*

Printer and Plotter Port Data Rates

Up to 150Kbytes per second (parallel) with IBM 4029
LaserPrinter Fastbytes mode

Up to 38.4Kbits per second (serial)

Printer and Plotter Cables (not included)

25-pin parallel (printers); 9-pin serial adapter; 25-pin
serial (printers); 36-pin Centronics (printers); 25-pin serial
(plotters)

IBM 4033 Models 1 and 11 (Token-Ring)

9-pin D-shell connector: PC Adapter cable with ring data
rate of 4 or 16Mbps; Type 3 media filter cable; telephone
twisted pair with ring rate of 4Mbps

IBM 4033 Models 2 and 12 (Ethernet 10BaseT)

8-pin RJ-45 connector; unshielded twisted-pair telephone
cable

IBM 4033 Models 3 and 13 (Ethernet 10Base5 or 10Base2)

10Base5 AUI connector and 10Base2 BNC T-connector;
10Base2 BNC jack; RG-58 coaxial cable; 10Base5 15-pin
D-shell connector; attachment unit interface (AUI) cable

Limited Warranty

One year

*

 Models 12 and 13 also support Ethernet Type II (AIX).

 Self-test

 Start

The following tests describe what might be wrong if an error occurs and what action
to take.

Note:  If the adapter is replaced, the customer must delete all associations after
removing the adapter from the LAN. When the replacement adapter is connected to
the LAN, the customer must perform the configuration steps and establish new
associations.

 Power

The power LED should always be on when there is power to the adapter. If the
power LED is off:

On Models 0XX, make sure the green dot faces up on the power cord to the
adapter. Check for +5VDC and +1 2VDC the power supply connector (US Models
001, 002, 01 011, and 012 have only +5VDC). Pin 2 is ground. If the power to the
adapter is correct, replace the operator panel board.

On Models 2XX and 3XX, if the power to the adapter is correct, replace the
adapter.

Reset, LAN Connected

To reset the adapter, press the Reset button.
 

 Models 0XX:

The status LED should blink several times within 3 to 4 seconds, turn off for up to
30 seconds, then turn on solid.
 

Models 20X and 30X:

The following LED sequence occurs during a normal reset. A successful reset
results in the Power and Status LEDs on and the Test and Data LEDs off.

If an error is detected the LEDs will hang in their current state. Reset again and
replace the adapter if the error recurs.

Common Problems and Fixes

 Model 0XX:

Status

Test

Data

off

on

off

off

off

off

on

off

off

Symptom

Action

Status LED on

The adapter is functioning correctly. Go to “Wrap
Test for Adapter Ports” on page 2.

Status LED blinking

There is a problem with the adapter or the LAN. Go to
“LAN Connection Check” on page 2.

Status LED off

Replace the operator panel board. If the problem
recurs, replace the adapter.

Status

Test

Data

off

off

off

on

on

on

off

on

on

95-05-26 
All rights reserved.

LM-4

1

Reviews: