background image

 

HYPERTEC UNINTERRUPTIBLE 

POWER SUPPLY 

 

 

 

USER’S MANUAL 

SBUPS600VA  

SBUPS1000VA  

SBUPS1500VA 

Summary of Contents for SBUPS1000VA

Page 1: ...HYPERTEC UNINTERRUPTIBLE POWER SUPPLY USER S MANUAL SBUPS600VA SBUPS1000VA SBUPS1500VA...

Page 2: ...e Operating Practices 4 Battery Information 6 Introduction 7 Performance 7 Installation Instructions 9 Physical Appearance 10 Front Panel Operational Indicators 11 Operation 12 Specification 13 Mainte...

Page 3: ...ervice please contact your nominated service agent Conditions of Use This equipment is designed for domestic use only The manufacturer neither recommends nor knowingly sells this product for use in cr...

Page 4: ...ric shock There are no user serviceable parts inside For service please contact your nominated service agent 1 The Hypertec UPS will provide a 220 240VAC 1 single phase rate power source Please verify...

Page 5: ...unication port are kept separated by at least 25 mm from the power cords to and from the UPS input and output Safe Operating Practices This pluggable type A equipment has factory installed batteries a...

Page 6: ...connector before the power has been disconnected 5 Turn off and unplug your UPS from the outlet and contact your nominated service agent if o The power cord or plug damaged o Liquid has been spilled o...

Page 7: ...recaution should be observed when working on batteries Remove watches rings or other metal objects Use tools with insulated handles 4 NOTE The batteries used in your Hypertec UPS are maintenance free...

Page 8: ...pable of self protection and fault diagnosis A built in AVR function automatically adjusts itself to maintain a power supply of stable voltage when the utility power is of high or low voltage High per...

Page 9: ...ttery capacity Automatic Voltage Regulation Corrects over and under voltages without draining the battery This preserves battery resources and ensures your UPS will provide the optimum runtime and opt...

Page 10: ...ect the AC input power cord to a socket outlet to power up the UPS The battery in the UPS will lose some charge during shipping and storage It will recharge completely after approximately 8 hours of n...

Page 11: ...witch 2 LED 1 GREEN AC Normal Status LED 3 LED 2 YELLOW Battery Charging LED 4 LED 3 RED Battery State of charge LED 5 AC Power socket outlets 6 Phone Fax line Surge Suppressor 7 USB Communications Po...

Page 12: ...FF UPS OFF Mains Normal Batteries Charging ON ON OFF 2 second Interval Beeping UPS ON Mains Mode OFF OFF BLINK Beeping every 5 seconds Mains not present Battery Backup mode 2 beeps per second i Low ba...

Page 13: ...Battery Beeping 2 times every 1 second In Backup mode when the battery energy runs low the UPS beeps rapidly until the UPS shuts down due to complete battery discharge Overload Beeping 4 times every...

Page 14: ...10 Output Characteristics Rated Output Voltage 230V 10 Output Frequency 50 Hz 10 Output Waveform Modified Square Wave Power Factor 0 6 Change Over Time Typ 0 4ms Max 10ms Battery Information at 25 C...

Page 15: ...1 With normal use a UPS battery will last 2 to 3 years depending on the number of discharges and operating ambient temperatures 2 Charge the UPS s battery every 3 months during extended storage 3 Disc...

Page 16: ...he monitoring software must first be installed Please install the software according to the following steps For information on how to operate the software refer to the On CD manual When the software C...

Page 17: ...3 Enter details as requested on this screen Your product serial number will be on the CD envelope Click NEXT 4 Choose the installation directory Click Next 16...

Page 18: ...5 Select language English is Default Click NEXT 6 Software will Now Install 17...

Page 19: ...7 Installation is now complete Click FINISH 8 The program is now running For information on how to operate the software refer to the On CD manual 18...

Page 20: ...Load configuration reference UPS VA PC power ATX Watt 0 6 Monitor VA Monitor power reference 15 CRT 15 LCD 17 CRT 17 LCD 19 CRT 19 LCD 80VA 40VA 130VA 60VA 180VA 80VA 19...

Page 21: ...ndition UPS always at battery mode PCB failure Contact Service Agent i Short Circuit Remove the non critical loads Buzzer continuously sounding ii UPS Faulty Contact Service Agent UPS does not provide...

Reviews: