Please take note of the following symbols used within this document:

 Warning:

 Hazards associated with electric current and high voltages

 
 

Important:

 Important information

Hydor’s policy is one of continual improvement and the right to change a specification at any time 
without notice is reserved. Whilst every care has been taken to ensure that the contents of this 
document are correct at time of publication, Hydor shall be under no liability whatsoever in respect 
of such contents. 

Hydor cannot guarantee the operation of any equipment unless all documented instructions are 
complied with, without variation.  
 
Hydor is a registered trademark of EG Agri Ltd and is a member of Elta Group. All other trademarks, 
trade names or company names referenced herein are the property of their respective owners. 

Installation and Maintenance Instructions.

THESE INSTRUCTIONS MUST BE READ FULLY BEFORE COMMENCING INSTALLATION.

Owner / installer: 

The life of this apparatus and its efficiency will be increased if 

its use and maintenance is carried out in accordance with these instructions and 
current statutory requirements. The installation and initial adjustments should 
be carried out by a qualified and competent technician. Hydor Limited should be 
consulted before substituting or fitting parts from another manufacturer. It is the 
responsibility of the installer to verify that the installation is in accordance with all 
current statutory requirements and the owner is given the current User’s Manual.

Any modifications to the fan or its installation, even the smallest 
modification, change or elimination of security components or pieces 
that influence the efficiency or loss of ventilation, will result in the CE 
Certification and Hydor’s warranty being cancelled.

HXP EC

incorrect

correct, minimum height 5mm

Summary of Contents for HXP EC

Page 1: ...wners Installation and Maintenance Instructions THESE INSTRUCTIONS MUST BE READ FULLY BEFORE COMMENCING INSTALLATION Owner installer The life of this apparatus and its efficiency will be increased if its use and maintenance is carried out in accordance with these instructions and current statutory requirements The installation and initial adjustments should be carried out by a qualified and compet...

Page 2: ...es up to 60 C The fan is not suitable for corrosive or explosive atmospheres 1 7 The installer should provide easy access to the fan to facilitate future maintenance 1 8 The installer should ensure the fan is adequately supported 1 9 This product is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless the...

Page 3: ...erval between consecutive starts 5 minutes 3 5 Maximum 1 connection from power supply cycle per 5 minutes 4 Fan Maintenance 4 1 Inspection of the fan at least once every 3 months is recommended to ensure that the motor fan blades and supporting guards are clean Any build up of dust and deposits on the blades or guards should be removed using a non abrasive cleaner 4 2 All fastenings including elec...

Page 4: ... to the external control is limited by the potentiometer setting of the commissioning device 10 07 2018 MK 149 CD POT Issue Saved Date A The 149 CD POT is a commissiong device designed to be used with our EC range of fans The device will allow the for the installer to set the maximum operating speed of the fan that it is connected to The installer or commissioning engineer can adjust the fan speed...

Page 5: ... fan controller compatibility GND 10V E1 MIN MAX E1 GND ST1 ST2 GN MAX MIN ST1 GN THE A ST2 C YOU C DISCO MULT BETW PLEAS THIS IS THE INTERNAL POTENTIOMETER THIS POTENTIOMETER CAN BE ADJUSTED FOR SINGLE SPEED SETTING OR MAX SPEED SELECTION THIS LINK JUMPER SHOULD BE REMOVED WHEN USING AN EXTERNAL POTENTIOMETER OR EXTERNAL CONTROL SIGNAL CONNECTED TO ST1 TH S C 149 CD POT 10 07 2018 POT Issue Saved...

Page 6: ...60 1EC SCP630 1EC SCP710 1EC 1 4 3 2 149 CD POT ST2 ST1 GND E1 MAX MIN E1 10V GND GREEN YELLOW BROWN BLUE 1PH EC SINGLE FAN C W ONEWAY SWITCH SINGLE FAN N L 220 277V1PH50Hz MAINS SUPPLY BROWN BLUE G Y YELLOW WHITE BLUE RED CONTROLS POWER L N PE MAX SPEED TRIMMER JUMPER REMOVED BROWN BLACK 5 6 FOR USEWITH SCP250 1EC SCP315 1EC SCP350 1EC SCP400 1EC SCP450 1EC SCP500 1EC SCP560 1EC SCP630 1EC SCP710...

Page 7: ... NGLE FAN AL Tag Purpose Description L Live Live power supply 220 277V N Neutral Neutral from power supply Permanent Earth Permanent earth from power supply 1 DCVoltage 2 10V DC control voltage input 2 to 10VDC input 2 DC Current 4 20mA DC control current input 4 to 20mA input 3 Frequency 10 95 Frequency duty cycle PWM Voltage 10 to 24Vpk Frequency 80Hz 10 to 95 input 4 Speed Reference Tacho outpu...

Page 8: ...eturns Note Number carriage paid for further examination EG Agri Ltd Hydor Unit 8 Parkers Close Downton Business Centre Downton Salisbury Wiltshire SP5 3RB UK Tel 44 0 1725 511422 Email info hydor co uk Web www hydor co uk idealair group Unit 1 Building 1 Sydney Corporate Park 85 O Riordan Street Alexandria NSW 2015 Tel 61 02 8073 3310 Fax 61 02 8073 3320 Email info idealairgroup com au AMS 11 Ing...