background image

H

CORPORATION

H

W

R

AP28873

www.hwh.com

Ph:  800/321-3494 (or) 563/724-3396  |  Fax:  563/724-3408

2096 Moscow Road  |  Moscow, Iowa 52760

(On I-80, Exit 267 South)

HWH CORPORATION

ML28874/MP05.9450

22SEP03

Single Cylinder Generator Slide

FEATURING:

(With Synchronizing Cylinders)

Three Dual Cylinder Room Extensions

HWH  HYDRAULIC SPACEMAKER

ROOM EXTENSION SYSTEMS

OPERATOR’S MANUAL

R

R

Summary of Contents for HYDRAULIC SPACEMAKER

Page 1: ...4 3408 2096 Moscow Road Moscow Iowa 52760 On I 80 Exit 267 South HWH CORPORATION ML28874 MP05 9450 22SEP03 Single Cylinder Generator Slide FEATURING With Synchronizing Cylinders Three Dual Cylinder Room Extensions HWH HYDRAULIC SPACEMAKER ROOM EXTENSION SYSTEMS OPERATOR S MANUAL R R ...

Page 2: ...urchased the vehicle or had the leveling system installed Dealership management people are in the best position to resolve the problem quickly If the dealer has difficulty solving the problem he should immediately contact the Customer Service Department at HWH CORPORATION If your dealer cannot or will not solve the problem notify the Customer Service Department HWH CORPORATION 2096 Moscow Rd Mosco...

Page 3: ...oper ride height and the leveling jacks are Do not operate the room extension unless the IMPORTANT 2 Apply the parking brake the ignition switch must be OFF after the room is fully extended or stops moving in the EXTEND position for more than ten seconds of the room do not reverse direction of the room until after the room is fully extended This assures proper Hold the switch to EXTEND three or fo...

Page 4: ...lide press and hold the GENERATOR SLIDE CONTROL SWITCH in the RETRACT position When the slide is fully retracted release the GENERATOR SLIDE CONTROL SWITCH than ten seconds after the slide is fully retracted or stops CONTROL SWITCH in the RETRACT position for more Do not hold the GENERATOR SLIDE IMPORTANT Releasing the GENERATOR SLIDE CONTROL SWITCH will halt the operation of the slide NOTE 3 If t...

Page 5: ...TIONS AND INSTRUCTIONS MAY CAUSE FAILURE OF THE MANUAL RETRACT WINCH OR CONNECTIONS RESULTING IN DAMAGE OR PERSONAL INJURY MAINTAIN FIRM GRIP ON THE WINCH HANDLE AT ALL TIMES NEVER RELEASE THE HANDLE WHEN RATCHET LEVER IS IN THE OFF POSITION AND THE WINCH IS LOADED THE WINCH HANDLE COULD SPIN VIOLENTLY AND CAUSE PERSONAL INJURY CHECK THE WINCH AND STRAPS FOR DAMAGE OR WEAR AND CHECK FOR PROPER RAT...

Page 6: ...ather cap from the top of the hydraulic oil reservoir The oil level should be approximately one inch below the top of the reservoir FLUID HWH Specialty Hydraulic Oil is recommended In an brake fluid or hydraulic jack fluid Use of these can damage and can cause staining should a leak occur DO NOT USE Dexron automatic transmission fluid contains red dye emergency Dexron automatic transmission fluid ...

Page 7: ...E POWER UNIT RESERVOIR IMPORTANT PRIOR TO REMOVING THE BREATHER CAP EITHER TO CHECK THE OIL LEVEL OR TO USE THE 1 4 NUT DRIVER CLEAN ANY DEBRIS FROM THE TOP OF THE RESERVOIR INCLUDING DEBRIS INSIDE THE 1 4 NUT DRIVER REMOVE ANY PAINT CHIPS OR OTHER DEBRIS FROM THE DIPSTICK BEFORE RETURNING THE BREATHER CAP TO THE RESERVOIR VALVE RELEASE NUT to the valve may result turn counter clockwise Damage NOT...